Pen-Style Residual Chlorine Tester

The pen-type residual chlorine detector utilizes an electrochemical sensor, which generates a current signal through the reaction between the electrode and residual chlorine in water. This signal is then converted by the circuit into a concentration reading. It is used for the rapid detection of free chlorine in water bodies such as tap water and swimming pools, ensuring that the disinfection effect meets the required standards.
Selection
When selecting, pay attention to whether the detection range covers the usage needs, review the instrument calibration methods and cycles, and confirm the replaceability of sensors. Consider the protection level to suit the on-site environment, verify the stability of the supply of supporting reagents, and check the display screen clarity and operational logic.

Terms

Standards

Instruments

Measurement range covers 0~ 5mg/L residual chlorine total chlorine and 0~ 10mg/L chlorine dioxide, support 100 measurements, suitable for water quality testing, easy and fast operation.

$ 128.00

Using BNC connector design, equipped with 60mL calibrated solution and residual chlorine regulator, replaceable membrane to extend service life, suitable for water quality monitoring.

$ 309.00

Designed for residual chlorine ElectRode Reagent, 250ml size, provides stable ionic strength adjustment to ensure fast and accurate ElectRode Response in the measurement process, suitable for various water quality testing environments.

$ 127.00

Iodine Reagent Formula specially designed for residual chlorine ElectRode, 250ml Encasement to meet routine testing needs, with ElectRode can improve Measurement accuracy and Stability, suitable for a variety of water quality environments.

$ 127.00

Designed for residual chlorine ElectRode, with a capacity of 250ml, it provides stable calibrating performance, ensures reliable measurement results, and is suitable for a variety of water quality analysis scenarios.

$ 110.00

Simultaneous measurement of residual chlorine, chlorine dioxide, total chlorine and other five paraMeters, resolution of 0.001mg/L, Repeatability 2%, micro-processing technology and high Reliability integrated circuit to ensure long-term stable work.

$ 622.00

Simultaneous measurement of turbidity, residual chlorine and total chlorine with EPA custom Illuminant, USEPA 180.1 compliant, automatic range conversion, turbidity Measurement range from 0.00 to 4000 NTU, support for multi-unit display and GLP data management.

$ 3878.00

8Nm Narrowband Interference filter and LED Illuminant, wavelength accuracy +/- 1nm, support residual chlorine and total chlorine 0.00-5 mg/L Measurement range, built-in reaction Timer and 50 sets of Data storage, with IP67 waterproof performance.

$ 632.00

Measurement range 0~ 5mg/L, can carry out 100 measurements, suitable for a variety of water quality analysis instruments, easy to operate quickly detect residual chlorine and total chlorine content.

$ 122.00

Measurement range 0~ 5mg/L, support 100 measurements, suitable for a variety of water quality analysis instruments, easy to operate and quickly detect residual chlorine content.

$ 114.00

With high and low turbidity ranges (0.00-9 and 100-1000NTU) and residual chlorine total chlorine measurement (0.00-5 mg/L), using EPA-specific Illuminant, supporting chroma compensation and Automatic calibration, storing 200 sets of data, suitable for a variety of water quality testing scenarios.

$ 2505.00

Using micro-processing technology and high Reliability integrated circuit, with data nonlinear processing and smoothing function, fast automatic multi-point correction, Measurement range residual chlorine 0~ 2.5mg/L, chlorine dioxide 0~ 5.0mg/L, Repeatability 2%, to ensure long-term stable work.

$ 428.00

Measurement range 0~ 5mg/L, support residual chlorine and chlorine dioxide dual paraMeter detection, a single package can complete 100 measurements, supporting special instruments to use convenient and fast.

$ 122.00

Optical inspection system using cold Illuminant narrowband interference, Optical inspection stability is less than 0.002A/20min, can save 20 standard Linear dispersion and 199 measured values, IP65 protection design to adapt to the field environment.

$ 499.00

Colorimetric measurement using DPD method, Measurement range of 0.00~ 5.00mg/L, providing 100 tests to ensure accurate determination of free chlorine concentration.

$ 151.00

Articles

Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Advantages of Barcol Hardness Tester in Rapid On-site Coating Hardness Testing
The Barcol hardness tester is a portable device suitable for rapid on-site measurement of coating hardness. It determines the hardness value by measuring the depth of penetration of the indenter, offering simple operation and test completion within seconds.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
How to Choose Between IPX3 and IPX7 for a Rain Test Chamber? Understand the Rating Comparison Table and You'll Know
The rain test chamber is used to simulate product waterproof testing, with its core being the IP protection rating. IPX3 represents protection against spraying water, simulating rain splashes through a swinging pipe spray, suitable for outdoor lighting fixtures, etc. IPX7 represents protection against short-term immersion, simulating water submersion through soaking, suitable for portable devices.