High-temperature wear testing machine

The high-temperature wear testing machine simulates a high-temperature environment using a heating device, bringing the sample into contact with abrasive materials and allowing relative motion to test the material's wear resistance under high temperatures. It is used in industries such as coatings, plastics, and inks to evaluate the durability of products under high-temperature usage conditions.
Selection
When selecting a high-temperature wear testing machine, it is essential to consider the temperature range and its compatibility with the samples, ensure the wear method aligns with testing standards, confirm that the control precision meets requirements, verify that the equipment structure accommodates sample dimensions, prioritize ease of operation and maintenance, and ensure the data recording functions are practical.

Terms

Standards

Instruments

The digital display temperature control is accurate and reliable, the hot air circulation system is composed of a high temperature fan and a suitable air duct to improve the Temperature uniformity in the working room, and the heating wire is installed at the bottom to heat up quickly.

$ 2171.00

With two test stations, the load range is 50~ 1000g, and three typical wear resistance tests of alcohol, eraser and pencil can be carried out, which is suitable for wear resistance evaluation of various coatings and materials.

$ 572.00

Probe surface with wear-resistant aluminum alloy, braided cable to adapt to high temperature rough surface, resolution up to 0.1 μm, support split remote measurement, can store 2500 readings.

$ 448.00

Adopting high-temperature non-alkali fiberglass insulation layer sealing resistance wire, the heating area is large and the temperature rises quickly, the maximum operating temperature is 380 ° C and supports continuous work, and the hemispherical design is not easy to bruise Glass ware.

$ 222.00

Inlet and outlet devices are used to intRoduce inert gas to effectively prevent oxidation and decarburization of high-temperature heating workpieces. The Furnace volume is 16L and the maximum temperature is 1200 ° C. The high-temperature spraying process of the shell is durable.

$ 954.00

Spreader width 100mm, wet film thickness 200μm, high-quality wear-resistant corrosion-resistant alloy steel material, can be manually or automatically film, support non-standard customization, suitable for a variety of material coating preparatory and performance testing.

$ 143.00

Rotation speed 40rpm and roller diaMeter 150mm design, suitable for a variety of resilience material testing, abrasion Travel 40mm, test load optional 5N or 1N, to ensure efficient and accurate wear performance evaluation.

$ 1101.00

Double station design can simultaneously carry out two sets of tests, round trip 0-50mm adjustable, test load 80-990g adjustable range, equipped with a variety of weight to meet the wear resistance performance evaluation requirements under different load conditions.

$ 824.00

Using Nidec compressor and DuPont environmental protection refrigerant, Humidity control accuracy of 0.1 ℃, equipped with double-decked vacuum heating defrosting observation window and stainless steel sample holder, support multi-stage programming and Data storage.

$ 3301.00

With no-segment adjustable Friction Frequency, speed range of 60 times/minute, support 10-50mm friction distance free adjustment, mirror stainless steel material, provide a variety of clamping and wear mode, power failure memory function to ensure test continuity.

$ 520.00

Measurement range 0~ 10000μm, error +/- 3%, wear-resistant aluminum alloy Probe surface, braided cable high temperature resistance, split structure can extend cable length to achieve remote measurement, can read more than 180 data per minute.

$ 2241.00

Made of wear-resistant and corrosion-resistant alloy steel, with a Hardness of 52 +/- 2HRC, it has upper and lower working surfaces to improve work efficiency and tool life.

$ 98.00

Adopting high-temperature non-alkali fiberglass insulation layer sealing resistance wire, the heating area is large and the temperature rises rapidly, the maximum operating temperature is 380 ℃, the hemispherical inner thermal design avoids bumping Glass ware, and supports Continuous Operating Mode.

$ 206.00

Using fiber wear-resistant pen tip, size 138mm long, 15ml large capacity, Accuracy up to +/- 0.5 dyne, can test a variety of materials Surface Energy value and cleanliness, easy and fast operation.

$ 99.00

Measurement range 0-5000μm, accuracy +/- 2% H + 1μm, wear-resistant Probe life over 500,000 times, support single point and multi-point calibrating, suitable for various environments.

$ 240.00

Articles

Application of Linear Abrasion Tester in Testing Scratch Resistance of Printing Ink Coatings on Packaging
This article introduces the principle, method, and application of the linear abrasion tester in testing the scratch resistance of packaging printing ink coatings.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Selection of abrasion testing machine is based on the wear form, choosing between linear or rotational types.
When selecting a wear testing machine, the first step is to determine based on the primary wear forms the material actually encounters.
Rotating Rubber Wheel Abrasion Tester for Determination of Coating Taber Abrasion Index
This article introduces the method for determining the Taber abrasion resistance index of coatings using a rotating rubber wheel abrasion tester.
Wear testing machine evaluates the wear resistance performance of wood and floor coatings.
This article introduces how to use a wear testing machine to evaluate the wear resistance of wood and floor coatings.
Friction and wear testing machine evaluates the wear resistance of self-lubricating polymer materials.
This article introduces how to use a friction and wear testing machine to evaluate the wear resistance of self-lubricating polymer materials. It explains the working principles of the testing machine, including the basic formulas for measuring the friction coefficient and wear rate.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.