Low-temperature coolant pump

The low-temperature coolant pump mechanically circulates and transports low-temperature liquids (such as ethylene glycol solutions) through a closed pipeline to remove heat from equipment. It is used to maintain low-temperature environments in devices like constant temperature chambers and reaction vessels, commonly applied in material testing and temperature control processes in chemical engineering.
Selection
When selecting, match the thermal load and temperature range of the target equipment, and confirm the pump's flow and head parameters. Pay attention to the compatibility and antifreeze properties of the coolant, and check the low-temperature resistance of the sealing material. Consider operational noise and installation space, and verify the type of power interface. Regularly maintain the filter screen and pipeline seals.

Terms

Standards

Instruments

Proportional refrigeration technology and high temperature direct drop technology, Temperature range -80~ 40 ℃, cooling capacity 400W, built-in pressure suction pump, Flow rate 12L/min, support short time idling and impurity resistance.

$ 4677.00

Proportional refrigeration technology and high temperature direct drop technology, Temperature range -20~ 100 ℃, fluctuation value +/- 0.1 ℃, built-in pressure suction pump maximum Flow rate 22L/min, support short time idling and low level protection function.

$ 2504.00

Temperature range -20~ 100 ℃, cooling capacity 700W, built-in pressure suction pump Flow rate up to 22L/min, support high temperature direct drop and short-term idling of the pump head, long service life.

$ 1890.00

Proportional refrigeration technology implementation -40~ 40 ℃ wide temperature control, built-in high temperature pressure pump to support 80~ 300 ℃ environment operation, Flow rate of 22L/min and the pump head can be idling for a short time, improve equipment durability.

$ 1768.00

Temperature range -20~ 100 ℃, cooling capacity 1200W, support high temperature direct drop technology, built-in pressure suction pump can withstand high temperature work of 80~ 300 ℃, with low liquid level protection and a variety of safety protection functions.

$ 2013.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with six safety devices such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.

$ 895.00

Adopt proportional refrigeration technology and high temperature direct drop technology, temperature fluctuation +/- 0.1 ℃, pump maximum Flow rate 22L/min, support short time idling and low liquid level protection, long service life.

$ 2136.00

Proportional refrigeration and PID technology, equipped with 22L/min large Flow rate pump, support high temperature direct drop and short-term idling protection, temperature fluctuation only +/- 0.5 ℃, adapt to 80~ 300 ℃ high temperature environment.

$ 1915.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, temperature control accuracy +/- 0.5 ℃, with low water level protection, temperature runaway alarm and other multiple safety functions to ensure the stable operation of the experiment.

$ 2654.00

Proportional refrigeration technology and PID technology, Temperature range -40~ 100 ℃, built-in pressure suction pump Flow rate up to 22L/min, support high temperature direct drop and short time idling protection, long service life.

$ 2136.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with six safety protections such as low water level protection and temperature runaway alarm to ensure the stability and reliability of the experimental process.

$ 6544.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety devices such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.

$ 1156.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, resolution 0.01 ℃, with low water level protection, temperature runaway protection and other multiple safety devices to ensure stable operation of the equipment.

$ 5200.00

Adopt proportional refrigeration and PID technology, temperature fluctuation +/- 0.5 ℃, support high temperature direct drop and short-term idling of pump head, Flow rate 22L/min, head 10m, long impurity resistance life.

$ 2258.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.

$ 3586.00

Articles

The main difference between the high-low temperature test chamber and the constant temperature and humidity test chamber
This article mainly distinguishes between high-low temperature test chambers and constant temperature and humidity test chambers.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.