Density measuring Balance

Density measuring balances are based on Archimedes' principle, calculating density by measuring the mass difference of an object in air and in liquid. They are used for detecting material density, porosity, and compositional uniformity, and are applied in quality control across industries such as chemicals, plastics, and ceramics.
Selection
When selecting a density balance, consider the range matching the sample weight, precision meeting detection standards, and compatibility with liquid medium characteristics. The balance should feature temperature compensation, a clear operating interface, and corrosion-resistant construction. Verify the equipment calibration certificate and manufacturer technical support.

Terms

Standards

Instruments

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, solid and liquid Density testing is supported, and the standard Density kit is easy to operate.

$ 841.00

Density direct reading function can avoid cumbersome calculation, equipped with all stainless steel Density bracket, weighing range 120g, accuracy 0.0001g, suitable for a variety of sample testing.

$ 1151.00

Density direct reading function eliminates cumbersome calculations, equipped with all stainless steel Density bracket, weighing range 200g, accuracy 0.001g, suitable for a variety of sample tests.

$ 546.00

High-precision Sensor for 0.01g Readability and 0.001g/cm ³ density accuracy, built-in multiple density references and rigorous calculation programs, supports solid liquid sample testing and directly displays density results.

$ 332.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeters can be customized, and solid Density, volume and metal purity measurement are supported.

$ 716.00

Density direct reading function eliminates the calculation step, can measure solid and liquid density, accuracy of 0.01g, Repeatability +/- 0.01g, all aluminum base design enhances weighing Stability.

$ 415.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeters can be customized, and various measurement modes such as liquid Density are supported.

$ 587.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, supports liquid Density measurement and custom setting of Density upper and lower limits, and standard RS232 interface is convenient for data transmission.

$ 496.00

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Capacity 300g and readability up to 0.01g. Standard Density kit and RS232 interface facilitate data transmission.

$ 446.00

With 0.001g/cm ³ density accuracy and 0.01g readability, support solid liquid density test, built-in density reference table can directly display the results, configure the battery to realize mobile measurement.

$ 332.00

Density direct reading function eliminates calculation steps, can measure solid and liquid density, accuracy to three decimal places, equipped with display shield and all aluminum base, enhanced dust and Stability.

$ 680.00

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Capacity 220g readability 0.1mg, standard Density kit and RS232 interface support data export.

$ 932.00

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Capacity 120g readability 0.1mg, standard Density kit and various unit switching functions.

$ 887.00

Can test solid, liquid, powder and Water Absorbency samples, density accuracy of 0.005g/cm ³, built-in a variety of density reference and rigorous calculation program, High Accuracy Sensor to ensure stable weighing.

$ 525.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading function response time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeters can be customized, standard RS232 interface supports data direct transmission.

$ 845.00

Articles

The Application of Contact Angle Measurement Instruments in the Study of the Relationship Between Ink Printing Wettability and Substrate Surface Tension
This article introduces how a contact angle measuring instrument is used to study the relationship between wettability and substrate surface tension in ink printing. It first explains the principle, assessing the degree of wettability through the size of the contact angle, where an angle less than 90 degrees indicates good wettability.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Application of Linear Abrasion Tester in Testing Scratch Resistance of Printing Ink Coatings on Packaging
This article introduces the principle, method, and application of the linear abrasion tester in testing the scratch resistance of packaging printing ink coatings.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Application of Drop Hammer Impact Testing Machine in Evaluating Impact Resistance of Composite Materials
This article introduces how the drop-weight impact testing machine evaluates the impact resistance of composite materials. The test releases a weight to strike the specimen, measuring parameters such as energy absorption, peak load, and damage area, simulating low-velocity impacts like tool drops.
Impact of the Fixture Design of a Drop Hammer Impact Tester on the Plastic Impact Strength Results
This article primarily discusses the impact of the fixture design of a drop-weight impact testing machine on the results of plastic impact strength tests. The geometric parameters of the fixture, clamping method, and contact surface material can alter the stress state and energy transfer of the specimen, thereby affecting the accuracy of the test data.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
Application of Tensile Testing Machine in 180-Degree Peel Strength Test for Packaging Tape
This article introduces how a tensile testing machine is used to test the 180-degree peel strength of packaging tape.