Adopting ALLHEAT cavity preheating technology, Temperature Uniformity +/- 0.5 ℃, equipped with ALLFLOW air circulation system, the temperature recovers quickly after opening the door, and supports remote monitoring and multiple over-temperature protection.
Using fuzzy PID controller to achieve accurate temperature control, Temperature Fluctuation +/- 0.5 ℃; Forced convection air duct system to improve Temperature uniformity; Mirror stainless steel liner with electric heating film heating, rapid and uniform heating; Independent temperature limit alarm to ensure experimental safety.
Mirror stainless steel liner and electric heating film heating, Temperature Uniformity +/- 1 ℃, heating speed, double-decked door design to reduce heat loss, four corners arc easy to clean.
Mirror stainless steel liner and diagonal air duct structure, Temperature Uniformity up to +/- 1 ℃, electric heating film heating rapid heating, double-decked door design to reduce heat loss, independent temperature limit alarm to ensure experimental safety.
The mirror stainless steel liner and electric heating film are used for heating, and the heating speed is fast; the diagonal air duct structure in the box ensures Temperature Uniformity +/- 1 ℃, and the double-decked door is designed with good thermal insulation and easy observation.
PID control technology implementation +/- 0.2% temperature fluctuation, mirror stainless steel liner acid and alkali easy to clean, carbon fiber electric heating film with preheating technology to ensure uniform temperature, volume 80L to meet various needs.
Mirror stainless steel liner diagonal duct structure to ensure Temperature Uniformity +/- 1 ℃, electric heating film heating rapid heating, double-decked door design to reduce heat loss, independent temperature limiting alarm system to ensure experimental safety.
The equilibrate refrigeration technology makes the temperature fluctuation small, equipped with fluorine-free R134 refrigerant to achieve energy saving and environmental protection, high temperature control accuracy and constant humidity, liner mirror stainless steel material is easy to clean and maintain, and the volume is 100L to meet the needs of various experiments.
Fuzzy PID controller is used to ensure accurate temperature fluctuation, forced convection duct to raise Temperature uniformity to +/- 1.5 ℃, automatic control of circulating fan speed to avoid sample volatilization, mirror stainless steel liner and electric heating film Heating mode to achieve rapid and uniform heating.
Fuzzy PID controller is used to control the temperature with accurate fluctuation, Temperature Uniformity +/- 1.5 ℃, forced convection air duct system to improve the temperature Response speed, independent temperature limit alarm system to ensure safety, optional ultraviolet sterilization to prevent pollution.
The cavity preheating technology is used to ensure uniform temperature distribution, and with an adjustable air circulation system, the Temperature Uniformity reaches +/- 0.5 ° C, supports remote monitoring and multi-device connection, and is easy to clean and maintain.
Fluorine-free design, temperature uniformity +/- 1 ℃, humidity fluctuation +/- 5 %~ +/- 8% RH, with over-temperature, leakage, Sensor fault multiple alarm protection functions to ensure safe operation of the experiment.
Fuzzy PID controller is used to realize +/- 0.5 ℃ temperature fluctuation, forced convection air duct system to ensure +/- 1.5 ℃ Temperature uniformity, mirror stainless steel liner with electric heating film Heating mode to achieve rapid and uniform heating.
Microcomputer temperature and humidity controller, Temperature Fluctuation +/- 0.5 ℃, humidity fluctuation +/- 5% RH, with over-temperature protection, independent temperature limit alarm system to ensure safe and stable operation of the experiment.
Adopt microcomputer intelligent temperature control, Temperature Fluctuation +/- 0.5 ℃, Temperature Uniformity +/- 1 ℃, with hot air circulation system and independent temperature limit alarm, support multi-stage programming and ultraviolet sterilization selection to ensure safe and efficient experiments.