Industrial Combustible Gas Alarm

Industrial combustible gas alarms detect the concentration of flammable gases in the air through catalytic combustion or infrared absorption principles. When the gas concentration reaches a preset threshold, audible and visual alarms are triggered, and ventilation equipment is activated. They are used in places such as petrochemical plants and painting workshops where there is a risk of gas leakage to ensure production safety.
Selection
When selecting an industrial combustible gas alarm, consider matching the sensor type to the gas being detected, ensuring the explosion-proof rating suits the on-site environment, and confirming the detection range covers potential leakage concentrations. Check the response time and calibration cycle to ensure long-term stable operation. The installation location should follow gas density characteristics: install at higher positions for lighter gases and lower positions for heavier gases.

Terms

Standards

Instruments

Using Semiconductor Sensor, Response Time T90 is less than 10 seconds, detecting a variety of combustible gases, range 0~ 50% LEL, with sound and light alarm and LED large screen display.

$ 141.00

Explosion-proof structure design, Response Time is less than 30 seconds, with 4-20mA standard signal output, can detect a variety of gas concentrations and set high and low alarm points to ensure industrial environment safety monitoring.

$ 267.00

Supports 4-20mA signal input, compatible with two-wire and three-wire devices, provides 6 passive switches and RS485 interfaces, with two-level alarm settings, operating temperature 0-40 ℃, suitable for gas safety detection.

$ 212.00

Industrial Sensor, Response Time less than 30 seconds, accuracy +/- 3% FS, with explosion-proof structure and 4-20mA standard signal output, suitable for a variety of Gas detection needs.

$ 267.00

High-precision Sensor is used to detect PM2.5 concentration, Response Time is instantaneous, Sensitivity can be adjusted to 5PPM, with sound and light alarm and automatic warm-up function, continuous work for 5 hours.

$ 157.00

Can simultaneously detect four gases, Electrochemical sensor, Response Time instant, alarm sound up to 80 decibels, operation temperature range -10~ 50 ℃, portable design weighs only 360 grams.

$ 241.00

Support 4-20mA/RS485 signal input, compatible with two-wire and three-wire devices, providing up to 6 passive switching quantities, two-level alarm can be freely set, suitable for gas safety detection.

$ 259.00

Support 4-20mA signal input and RS485 upload, with 2-level alarm and 2 relay output, compatible with two-wire and three-wire equipment, fast response speed and high measurement accuracy, suitable for a variety of Gas detection scenarios.

$ 140.00

Designed with explosion-proof and explosion-proof structure, Response Time is less than 30 seconds, Maximum power consumption is 3W, Support 4-20mA standard signal output, High Accuracy and stable performance, Suitable for a variety of industrial environments.

$ 267.00

Using infrared NDIR detection principle, range 0-5% Vol, Response Time ≤ 30 seconds, support 4-20mA, RS485 and switch output, with explosion-proof structure and remote monitoring capability.

$ 332.00

Using Industrial Sensor, Response Time less than 30 seconds, accuracy +/- 3% FS, shell explosion-proof structure, 4-20mA standard signal output, can detect a variety of gas concentrations and have sound and light alarm function.

$ 267.00

Electrochemical sensor, Response Time less than 30 seconds, Measurement accuracy +/- 3% FS, 4-20mA standard signal output and passive relay control port, suitable for a variety of Gas detection needs.

$ 267.00

It adopts flameproof structure design, supports 4-20mA, RS485 and switch output, Response Time ≤ 30 seconds, Detection error ≤ +/- 3% F.S. It can be operated by remote control without opening the lid, with sound and light alarm function, suitable for dangerous environment gas monitoring.

$ 254.00

Using catalytic combustion principle to detect 0-100% LEL range, Response Time ≤ 30 seconds, support 4-20mA and RS485 output, with flameproof structure and remote alarm function.

$ 383.00

Using semiconductor Sensor technology, the detection sensitivity can be adjusted to 50PPM methane, Response Time ≤ 1 second, Warm-Up Time is less than 110 seconds, support 9 hours of continuous work, with LED light alarm and low power indication function.

$ 99.00