Measurement range 50~ 1400kpa, accuracy ≤ +/- 0.5%, using the method of Miao Lun, support paper, aluminum foil and non-paper sheet material detection, film convex disc pressure 9mm, upper and lower disc concentricity ≤ 0.25mm.
The device uses 1200-1500lx Illumrination degree, achieves 80x magnification and 0.01mm resolution through scale Microscope, and can measure the maximum aperture of 2mm, suitable for aluminum foil pinholing light transmission observation.
Precision ball screw drive and double rail design, Force Measurement range 0.03-200 N, Accuracy grade 0.5, support a variety of unit selection and intelligent calculation test results, equipped with micro printer and overload protection function.
Precision ball screw drive system, Force Measurement range 0.005-30N, Accuracy grade 0.5, equipped with 5-inch high definition Touchscreen and intelligent operation function, support a variety of unit selection and USB data export.
Adopt 5 inch high definition Touchscreen and precision ball screw drive system, Force Measurement range 0.02-100 N, Accuracy grade 0.5, support a variety of units and intelligent operation test results, with overload protection and USB data connection function.
High strength aluminum alloy frame, Test Travel adjustable, Test speed 0-30cm/sec adjustable, Test times up to 999999 automatic shutdown, inspection Rod clearance loose and other faults.
Equipped with high light transmitance Glass liner, transmission Illumrination degree 1000Lux, reading Microscope magnification 100X, can accurately measure pinholing size and quantity.
The stamping sampling method is accurate and fast, the limit cutting thickness range is 0.0045~ 0.1mm, and the sampling error is only +/- 0.01mm. The special treatment die blade is used, and it can be used for 2 years without replacement. It is suitable for high-fiber paper, metal foil and other materials.
Maximum load 50Kg, Test speed 10~ 60mm/min adjustable, using pointer sensing mode, effective Travel 0~ 360mm, suitable for vertical angle disbonding test.
Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, independent temperature control of upper and lower heat sealing heads, good thermal conduction effect of brass heat sealing knife, double-decked thermal insulation design to ensure safe use.
The heat sealing paraMeters were determined by hot-pressing sealing method, the temperature control accuracy was +/- 1 ℃, the heat sealing time was adjustable 0.1-999 s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured the safety of use.
Aluminum block Bathroom heat transfer uniform heating, temperature control accuracy +/- 0.5 ℃, gas flow rate 0-15L/min adjustable, blow pipe independent to avoid cross-contamination, to achieve rapid oxygen-free condensing.
Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, heat sealing time 0.1~ 999.9s adjustable, heat head with brass material to ensure uniform heat conduction, double-decked thermal insulation protection to ensure safe operation.
It can measure the minimum inner diaMeter of 6mm aluminum tube and 8mm thickness profile, Indication Error 0.5HW, using high strength pointer and special steel pressure needle, support Hardness value multi-standard conversion.
The aluminum block Bathroom is used for uniform heat transfer, rapid and accurate temperature control, temperature control accuracy of +/- 0.5 ° C, display accuracy of +/- 0.1 ° C, gas flow rate of 0~ 15L/min, blow pipe to avoid cross-contamination independently, lifting stroke of 200mm.