Aluminum PycnoMeter

The aluminum specific gravity bottle determines the density of liquids using Archimedes' principle. A bottle of known volume is immersed in the liquid to be measured, the mass of the displaced liquid is weighed, and the density is calculated. It is used in industries such as coatings and inks to test the density of raw materials and control production processes.
Selection
When selecting an aluminum pycnometer, it is essential to match the measurement range with the sample density, taking into account the bottle's volume and accuracy requirements. The corrosion resistance of the material should suit the characteristics of the liquid being tested, while temperature compensation functionality helps address environmental variations. A calibration certificate ensures traceability of measurements, and ease of operation impacts testing efficiency.
material
Cup volume
Calibrated certificate

Terms

Standards

Instruments

The device uses 1200-1500lx Illumrination degree, achieves 80x magnification and 0.01mm resolution through scale Microscope, and can measure the maximum aperture of 2mm, suitable for aluminum foil pinholing light transmission observation.

$ 554.00

Measurement range 0.000~ 0.3mg/L, can be 100 measurements, supporting special instruments to achieve fast and accurate water quality aluminum ion detection, including a variety of Reagent solutions.

$ 164.00

It can measure the minimum inner diaMeter of 6mm aluminum tube and 8mm thickness profile, Indication Error 0.5HW, using high strength pointer and special steel pressure needle, support Hardness value multi-standard conversion.

$ 1219.00

Enclosed aluminum silicate Furnace and nickel-chromium-aluminum alloy heating wire are used to reduce volatile gas corrosion; three-sided heating method combined with PID control, Temperature Fluctuation +/- 5%, accurate and stable temperature control.

$ 1138.00

The activated aluminum oxide ball is used as the adsorption medium, which can adsorption water vapor and chemical corrosion harmful gases, and the oil blocking rate is more than 99%.

$ 146.00

Three-sided heating method with aluminum silicate Furnace, high thermal efficiency and uniform temperature. PID control combined with K-type Thermocouple, temperature control accuracy +/- 5%, support 0~ 9999 minutes timing and phased heating.

$ 606.00

With low temperature OLED display, it can still work normally in -40 ℃ environment; equipped with iron-aluminum dual-use Probe, automatically identify the substrate and convert the mode; Measurement speed is as fast as 0.5 seconds, error range +/- 3%.

$ 175.00

Using titanium anodic oxidation aluminum material, the filter is stainless steel, the diaMeter of the flow hole is 4.1mm, the viscosity range is 70-370cSt, the Cup mouth is designed with an anti-spill groove, and each Cup is engraved with a unique serial number.

$ 497.00

With double-decked anodic oxidation aluminum housing structure, temperature control is achieved by chilling down and heating liquid, suitable for a variety of standard viscosity Cups, hard anodic oxidation aluminum and stainless steel materials to ensure durability.

$ 1287.00

Made of aluminum alloy, with a size of 50 * 50mm and a clamping diaMeter of 16mm, it has a lifting adjustment function and a stable and durable structure.

$ 106.00

Using 5mm filter diaMeter, viscosity measurement range 91-326cSt, flow time 30-100 seconds, aluminum alloy material structure is strong, in line with international standards.

$ 427.00

Made of titanium anodic oxidation aluminum, the diaMeter of the flow hole is 2.5mm, and each Cup is engraved with an independent serial number, which is suitable for accurate measurement of liquid viscosity in the laboratory.

$ 438.00

Made of titanium anodic oxidation aluminum, the flow hole diaMeter is 6mm, the Cup height is 75mm, and each Cup is engraved with an independent serial number to ensure Measurement accuracy and durability.

$ 438.00

Cast aluminum shell, anti-static and anti-interference performance, with unit conversion, counting and printing functions, support full range peeling and overload alarm.

$ 283.00

Made of aviation aluminum alloy with anodic oxidation treatment, the weight is only 70 grams, and the precision overflow design can avoid the generation of bubbles and ensure that the density Measuring accuracy reaches +/- 0.5 ℃ temperature control requirements.

$ 704.00

Articles

Uniform coating of lithium-ion battery cathode slurry on aluminum foil.
This article primarily discusses how to uniformly coat the positive electrode slurry onto aluminum foil in lithium-ion battery manufacturing. The slurry itself exhibits shear-thinning properties, making it suitable for coating applications.
The film coater is used for experimental-grade uniform coating of lithium-ion battery cathode slurry on aluminum foil.
This article explores the technique of uniformly coating lithium-ion battery cathode slurry on aluminum foil using a laboratory-grade coating machine.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
From aluminum foil and copper foil to electrode coating, the laboratory coating machine handles it all in one go.
A laboratory coating machine is a sample preparation device used for material research and development and quality control. It evenly applies slurry onto substrates such as aluminum foil and copper foil, forming a film of specific thickness by controlling the drying process.
The coating machine in the laboratory ensures a more stable functional layer on the surface of copper and aluminum foils.
The laboratory coating machine is used to apply functional layers on the surfaces of copper foil and aluminum foil. By precisely controlling parameters such as coating speed, slurry viscosity, and drying temperature, it enhances the uniformity and adhesion of the coatings.
Selection of Ceramic vs. Cast Aluminum Heating Surfaces for Laboratory Hot Plates
When selecting a laboratory heating plate, ceramic and cast aluminum are two common materials. Ceramic offers high-temperature resistance, corrosion resistance, and uniform heating, but it heats up slowly and is relatively brittle. Cast aluminum heats up quickly and is sturdy and durable, but it has weaker corrosion resistance and a lower maximum temperature.