Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the accuracy of light transmitance and haze display is 0.01%, equipped with thin film magnetic fixture and liquid sample Cup, and supports 2000 sets of data storage.
Using D/8 ° illumination and integrating sphere design, the repeability accuracy Delta E * ab within 0.04, Inter-Agreement Delta E * ab 0.2, supports a variety of color difference formulas and Illuminant modes, and the measurement time is only 1.5 seconds.
Using parallel illumination hemisphere scattering integrating sphere photoelectric reception mode, light transmitance measurement range 0-100%, haze measurement range 0-99%, with open sample window design, not affected by environment light.
The colony contrast is clear by using ring lamp side-shot illumination, equipped with three-digit display and counting probe pen, the counter capacity is 0-999, and it has a 30-day charging standby function, which can reduce the experimental labor intensity.
Adopt D/8 ° illumination and Φ 58mm integrating ball, repeability accuracy Delta E * ab within 0.04, support liquid, powder and other sample testing, equipped with 3.5 inch capacitive Touchscreen and large capacity storage.
Compression stroke 2.50mm, load 237g, suitable for wet mold sand/core surface Hardness measurement, support USB and Bluetooth data output, with average calculation and undervoltage alarm function.
It has the function of switching between light and dark field of view, supports 40X-1600X magnification range, and uses oblique illumination to make the outline of the sample clearly visible. It is suitable for morphological observation of unstained biological samples.
D/8 illumination observation conditions, measurement time 20ms, 0.5mm distance from the sample non-contact measurement, built-in black and white calibrate and ETC real-time calibrate technology to ensure high repeability and accuracy.
Using infinite distance flat-field Brightfield color difference elimination objective, fretting grid value of 2 μ m, equipped with drop and transmission illumination system, can perform Brightfield, polarizing and DIC observation, suitable for semiconductor wafer inspection and precision mold analysis.
Equipped with 0.5/0 7/1.0 mm three thickness die frame, using baseplate fixed structure to ensure film uniformity, metal drawdown blade design to meet long-term use needs.
Suitable for manual or mechanical low and medium pressure molding of fine sand core testing, compression stroke 2.50mm, load 980g, with average calculation and MAX Maximum latch function, support data output communication.
Integrated Incubator and Shaker functions, Oscillation Frequency 40~ 300rpm, Temperature range RT + 5~ 65 ℃, 304 stainless steel liner and microcomputer PID control, with UV sterilization and automatic storage setting paraMeters.
Integrated Incubator and Shaker functions, small footprint and large bottle load; Temperature range 4~ 65 ℃, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner for easy cleaning, quiet operation and support multi-stage programming.
Adopting 45 °/0 ° illumination, the measurement area is about Φ 10mm, the Repeatability Standard Deviation is within Delta E * ab 0.5, and supports a variety of Color space display and statistical functions, making it easy to use.
Evaluate coating distinctness by 13 kinds of image grades, Illuminant illumination is not less than 1200X, E Illuminant irradiation and 5 reflection projection, test area is not less than 60x60mm, easy to operate.