Online SpectroPhotoMeter

An online spectrophotometer analyzes the concentration or color changes of substances by irradiating a sample with a light source and detecting the intensity of transmitted or reflected light. It is used for real-time monitoring of parameters such as color differences in coatings and inks, as well as the light transmittance of plastics in production processes, ensuring stable quality.
Selection
When selecting, consider matching the measurement wavelength range to the characteristics of the substance being measured, ensuring the protection rating suits the on-site environment, the response speed meets production line demands, interfaces are compatible with the control system, and maintenance cycles align with operational requirements.

Terms

Standards

Instruments

Micro vibration technology implementation of real-time online measurement, range 0~ 50~ 100mpa.s, accuracy +/- 0.5%, Response Time 2 seconds, suitable for a variety of fluid media.

$ 7335.00

The width is 5cm, the optical path is 10mm, and the dimensions are 12.5 × 52.5 × 45mm, which is suitable for the use of Spectrophotometer to ensure Optical inspection detection accuracy.

$ 114.00

Width 2cm, optical path 10mm, dimensions 12.5 × 22.5 × 45mm, specially designed for Spectrophotometer matching Cuvette, to ensure Optical inspection detection accuracy.

$ 101.00

The width is 3cm, the optical path is 10mm, and the dimensions are 12.5 × 32.5 × 45mm. As a special accessory for Spectrophotometer, it ensures the stability of the optical path and the accuracy of measurement.

$ 106.00

Micro vibration technology implementation of real-time online measurement, range coverage of 0-5~ 50-5000pa.s, accuracy of +/- 0.5%, temperature 500 ℃ and Response Time only 2 seconds, suitable for high temperature and high voltage conditions.

$ 7335.00

The laser light scattering principle to achieve rapid measurement, detection sensitivity of 0.001mg/m ³, with online automatic mechanical Adjustment, built-in optical path self-cleaning system to avoid contamination of core components, support a variety of cutter selection.

$ 5399.00

Fast measurement using laser light scattering principle, with online automatic mechanical Adjustment, Measurement range 0.01-100 mg/m ³, built-in optical path self-cleaning system to avoid pollution, support a variety of cutters and sampling modes.

$ 5399.00

Rotation speed up to 26000rpm, providing 27m2/s shear line speed, long-term stable operation, fine and uniform processing of materials, no dispersion dead angle, suitable for high viscosity up to 10000CP working conditions.

$ 2654.00

The brushless motor can run stably for a long time, the highest Rotation speed is 30000rpm, the shear line speed is 27m ²/s, the unique stator and rotor structure provides super strong shear force, and the processing without dispersion dead angle is more fine and uniform.

$ 2171.00

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, the passband is narrow, and the Sensitivity is high; the five elements can be combined with any combination of direct reading measurement at the same time, the Response Time is less than 8 seconds, and the relative change of Stability in 15 seconds does not exceed 2%.

$ 2655.00

Key parameters include inter-instrument agreement ΔE*ab ≤ 0.25 and chromaticity value repeatability ΔE*ab ≤ 0.02, with features such as automatic aperture recognition, high-definition camera positioning, a damping handle, and four UV measurement modes.

$ 6334.00

Micro vibration technology implementation viscosity measurement, range 0-5000mpa.s, accuracy +/- 0.5%, Response Time 2 seconds, with IP68 Protection Rating and a variety of connection methods.

$ 7335.00

Flow velocity 1.5L/min, reverse osmosis (RO) membrane and purification column are used to remove trace ions efficiently, and intelligent microcomputer control realizes automatic operation and online water quality monitoring.

$ 2784.00

Using magnetic Induction and eddy Current dual method, the measurement range is 10-3000μm, the accuracy is +/- 2μm/2%, with automatic substrate identification, online statistics and backlight display, suitable for various surface shapes.

$ 853.00

Single beam of light grating system, Wavelength range 340~ 1000nm, Light spectrum Bandwidth 4nm, sealing grating monochromator design to improve Stability and Metering accuracy, automatic adjustment 0% and 100% function to simplify operation.

$ 270.00

Articles

Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of UV Spectrophotometer in the Determination of Lignin in Pulp
This article introduces the application of ultraviolet spectrophotometry in determining the lignin content in pulp. Lignin is a key component affecting pulp quality. This method utilizes the characteristic absorption of lignin under ultraviolet light for measurement, offering simple and rapid operation.
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.
Guide to Avoiding Pitfalls When Purchasing a Spectrophotometer
When selecting a spectrophotometer, it is essential to first understand its working principle based on the Lambert-Beer law, as this helps in assessing the rationality of the instrument's design.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.