Water Quality Electrolyzer

A water quality electrolyzer electrolyzes water samples through electrodes, causing impurities in the water to undergo electrochemical reactions that produce precipitates or color changes. It is used for the rapid detection of indicators such as metal ions and hardness in water, commonly employed for on-site quick screening of drinking water and swimming pool water.
Selection
When selecting, consider whether the detection parameter range covers the requirements, the electrode material should be corrosion-resistant, the operation interface should be simple, calibration function support is essential, pay attention to portability and power supply adaptation methods, and check if basic data storage capability is available.

Terms

Standards

Instruments

With 12 water quality paraMeter detection capabilities, resolution of 0.001mg/L, Repeatability 2%, micro-processing technology and long-life Illuminant, support custom Linear dispersion calibrating and data smoothing.

$ 1058.00

Measurement range 0~ 500 ppm, accuracy +/- 3 ppm, support for CAL CheckTM Adjustment, suitable for a variety of water quality testing scenarios.

$ 215.00

Can simultaneously measure 7 water quality indicators, IP67 waterproof design, 45000 data storage capacity, support 1 second to 3 hours custom storage interval, with automatic temperature compensation and GLP management function.

$ 2615.00

Using composite ElectRode design, equipped with special reference filling solution and calibrating solution, Measurement accuracy is high, BNC interface compatibility is strong, suitable for a variety of water quality analysis scenarios.

$ 309.00

12 water quality paraMeters can be measured simultaneously, with IP67 waterproof rating and 45,000 data storage capacity, support automatic temperature compensation and fast calibrating, with backlit graphic display and intuitive Operating interface.

$ 2949.00

ED test technology integrates 8 specific absorption peak wavelengths, can detect more than 50 water quality items, supports user-defined 100 Measuring methods, with IP65 Protection Rating and 2000 sets of Data storage capabilities.

$ 1806.00

Simultaneous measurement of 7 water quality paraMeters, turbidity Measurement range 0-50NTU, accuracy +/- 5%, in line with USEPA 180.1 standard, with chroma compensation and Illuminant automatic compensation function, reducing interference without frequent calibrating.

$ 2363.00

Equipped with 18.25MΩ · cm ultra-pure water quality and 100L/H water pRoduction capacity, 7-inch color touchscreen displays three-way water quality and temperature in real time, supports consumables failure reminder and automatic circulation system to ensure stable water quality.

$ 5195.00

Can simultaneously measure 10 water quality indicators, including pH, ORP, conductivity, etc., with IP67 waterproof and automatic temperature compensation function, data storage capacity of 45,000, adapt to harsh environment measurement needs.

$ 3373.00

It can simultaneously measure 7 water quality indicators, IP67 waterproof level, 45000 data storage capacity, automatic temperature compensation and fast Adjustment, adapt to the harsh environment such as pipeline deep wells.

$ 2345.00

It can simultaneously measure 7 water quality paraMeters, equipped with 45,000 data storage capacity, adopts IP67 waterproof grade and intelligent ElectRode identification system, supports automatic temperature compensation and fast Adjustment.

$ 2074.00

Optical inspection Colorimetric detection principle, eliminate human error, measurement resolution of 0.1mg/L, Repeatability ≤ 2%, suitable for indoor and outdoor water quality testing environment.

$ 240.00

Can simultaneously measure 10 water quality indicators, IP67 waterproof design to adapt to harsh environments, built-in 45000 sets of data storage capacity, automatic identification of calibrating points to ensure Measurement accuracy.

$ 2247.00

Colorimetric integrated tube design, no need to transfer liquid, support more than 10 measurements to take the average value, measurement error ≤ +/- 5%, Repeatability ≤ +/- 5%, built-in two COD detection methods, can expand a variety of water quality paraMeter detection.

$ 2526.00

Support 16 water quality paraMeters synchronous testing, equipped with IP67/IP68 waterproof rating and automatic temperature compensation system, data storage capacity up to 45000 groups, Measurement range covers 0-400mS/cm conductivity and 0-1000FNU turbidity.

$ 8494.00

Articles

Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Heating and blade coating of gel electrolyte films for zinc-ion batteries.
This article introduces the heating doctor-blade coating method for preparing gel electrolyte films in zinc-ion batteries. The method involves spreading a slurry onto a substrate using a doctor blade, followed by heating to evaporate the solvent and form a film.
Heating coating machine is used for the doctor-blade coating of gel electrolyte films in zinc-ion batteries.
This article introduces the blade coating process for preparing gel electrolyte films for zinc-ion batteries using a heated coating mechanism. By controlling parameters such as temperature, coating speed, and gap height, this method enables the fabrication of films with uniform thickness and smooth surfaces.
Wavelength selection for the determination of sulfate content in water quality using photometric titrator
This article discusses how to select the wavelength when using a photometric titrator to determine the sulfate content in water. The core issue lies in the fact that wavelength selection directly affects the accuracy and anti-interference capability of the detection.
Application of Coulometric Moisture Titrator in Moisture Detection of Electronic Components
Coulometric moisture titrators operate based on the principle of electrolysis, directly calculating the moisture content in samples by measuring the electrolytic charge without the need for calibration. In the field of electronic components, moisture can lead to issues such as corrosion and reduced insulation, making its detection critically important.
Total Chlorine Content Microcoulometric Titration Detector for Pulp
This article introduces a method for detecting the total chlorine content in pulp using a microcoulometric titrator. The principle involves generating a titrant through electrolysis, which reacts with chloride ions produced from the combustion of the sample. The chlorine content is accurately calculated by monitoring the amount of electricity consumed.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
How to Choose a Suitable Multi-Parameter Water Quality Analyzer Based on Detection Indicators
When selecting a multi-parameter water quality analyzer, the first step is to clarify the parameters that need to be measured, such as physical, chemical, or biological indicators, because different parameters require different detection principles, measurement ranges, and accuracy levels for the instrument.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
How can multi-parameter water quality analyzers avoid cross-contamination and improve data accuracy?
This article mainly discusses how to avoid cross-contamination in multi-parameter water quality testing to ensure data accuracy. Cross-contamination refers to the residue from a previous sample affecting the results of the next sample, which may lead to data deviation.
Which is more convenient for water hardness testing: the electrode method or the titration method?
Both electrode method and titration are used to measure water hardness. The choice depends on specific needs: opt for the electrode method for speed, and choose titration for accuracy.