Adhesive Tape Thickness Gauge

The adhesive tape thickness gauge measures the thickness of adhesive tape using either a contact probe or a non-contact sensor. Its principle is based on mechanical contact or optical reflection, and its function is to detect the uniformity of the tape. It is applied in production quality control to ensure that the tape meets thickness standards.
Selection
When selecting an adhesive tape thickness gauge, consider the measurement range, accuracy, tape type, and operating environment. Prioritize matching the tape thickness and material characteristics to ensure instrument stability and ease of use, and evaluate cost and maintenance factors based on actual needs.

Terms

Standards

Instruments

Measured value 500N, suitable for tape, PCB, adhesive tape and other materials disbonding force test, supporting the Force Gauge test bench.

$ 89.00

Measurement accuracy of 0.007mm, Graduation of 0.001mm, probe diaMeter Φ 5mm, maximum measurement depth 45mm, suitable for on-site rapid thickness detection.

$ 251.00

Using 2000g +/- 5g roller load and 300mm/min rolling speed to ensure that the adhesive tape sample is flat and evenly adhered to the standard substrate, in line with CNS-11888 and PSTC-8 design standards.

$ 524.00

The adhesive force of the tape is 4.3N/cm, and the principle of cross-cut method is adopted, which is suitable for adhesion testing. The performance is stable and non-degumming, and the test results are accurate and reliable.

$ 166.00

The equipment tests the initial Tack by short contact between steel ball and adhesive tape sample at a small pressure, adjustable tilt angle 0~ 60 °, rolling ball range 1/32 inch to 1 inch, suitable for a variety of material adhesion evaluation.

$ 240.00

Equipped with 10-station synchronous test capability, 1000g weight and 1-999999 minute Timer, using SUS #304 steel plate to ensure test accuracy, and automatically recording tape peeling time.

$ 748.00

Measured value 500N, suitable for tape, leather, clothing, rubber, electrical components, paper and other materials, assist Force Gauge in tensile testing to ensure test Stability and accuracy.

$ 143.00

Measured value 1000N, suitable for rubber, cable, packing tape, electrical components and other materials tensile force, destructive force, insertion force test, designed for Force Gauge test bench.

$ 93.00

Measured value 50000N, suitable for tape, leather, paper and other sheet or block material push-pull force and destructive force test, supporting the Force Gauge test bench.

$ 104.00

Tack testing to assess adhesion by measurement of displacement or peeling time under specified weight. With thermostatic test chamber, multi-national standards are supported and the operation process is clear.

$ 2090.00

Measurement accuracy of 0.007mm, Graduation of 0.001mm, probe diaMeter of Φ 5mm plane, maximum measurement depth of 80mm, in line with national standards.

$ 267.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

11/16 inch standard width paper tape, capable of completing approximately 1800 cycles of testing per roll, must be stored at 23 +/- 2 ° C and 50 +/- 10% Humidity to ensure Stability.

$ 377.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.