Electric Coating Blending Machine

The electric paint mixer uses a motor to drive the rotation of spiral blades, creating a vortex in the container to evenly mix the components of the coating. It is used in laboratories and workshops for blending materials such as pigments and resins, preventing sedimentation and stratification to ensure the stability of the coating. It is suitable for the preparation and pre-treatment of fluid materials such as paints and inks before sampling.
Selection
When selecting, consider matching the stirring capacity with the sample volume. Choose high-speed models for low-viscosity materials, while high-viscosity materials require configurations with high torque. DC motors are suitable for frequent start-stop operations, whereas AC motors are better for continuous work. Pay attention to the compatibility of clamps with different containers and the speed control function to accommodate various materials. Noise and heat dissipation also affect the usage environment.

Terms

Standards

Instruments

The equipment adopts electric lifting and frequency conversion speed regulation, Rotation speed 0-3000 rpm, equipped with double-decked chilled down jacket and zirconia bead grinding medium to achieve efficient wet dispersion grinding, small temperature rise and easy operation.

$ 2655.00

Rotation speed 0-3000rpm, fineness of grinding can reach 10um or less, double-decked chill down jacket is used to control temperature rise less than 10 ℃, electric lifting operation is convenient, zirconia bead grinding medium to achieve efficient dispersion and ground synchronization.

$ 2676.00

Electric lifting design to achieve dispersed ground synchronization, maximum Rotation speed 3000rpm, fineness of grinding up to 10um or less, configuration double-decked chill down jacket temperature rise less than 10º, zirconia bead medium to ensure efficient grinding.

$ 3089.00

Using electric push Rod to drive Spreader movement, avoid manual Stability; equipped with touch screen real-time display of moving distance, support 2-200mm/s speed adjustment and 430 * 250mm effective coating area, Operating interface is simple and intuitive.

$ 1235.00

Adopt electric lifting system, lifting Travel 270mm, speed range 60~ 8000rpm, integrated mixing, sand grinding, dispersion multi-function, compact structure and low noise.

$ 562.00

Glass-lined, FRP, epoxy coal asphalt coatings of different thicknesses can be mass tested by high voltage detection technology. When the coatings have defects such as pinholing and bubbles, the instrument will emit bright sparks and sound and light alarms.

$ 1230.00

The equipment is designed according to the international coating stain resistance experimental method, the water Tank volume is 5L, the inner diaMeter of the flow pipe is 8mm, and the time control range is 0~ 99h99s. It is suitable for the stain resistance test of building exterior coatings.

$ 412.00

Rotation speed 3000rpm with zirconia bead grinding medium, fineness up to 10um or less; double-decked chilled down jacket design makes the operating temperature rise less than 10º; electric lifting structure is easy to operate and clean, suitable for medium and low viscosity material processing.

$ 2986.00

Using 2268 +/- 7g standard brush parts, sanding speed 50cpm, automatic counting function to ensure test Repeatability, linear reciprocating motion simulates actual sanding conditions.

$ 538.00

Spreader movement driven by electric push Rod, adjustable speed range of 2-200mm/s, equipped with Vacuum chuck table to effectively fix the substrate, Operating interface intuitively simplifies the process, improves Spreader accuracy and efficiency.

$ 2010.00

Adopt electric lifting system and frequency conversion speed regulation technology, Speed range 60~ 6900rpm, Power 1100W, equipped with dispersed impeller and sand grinding blades, can adapt to different impeller diaMeters, support chilling down water circulation temperature control.

$ 846.00

The equipment can complete two processes of dispersion and grinding at the same time, Rotation speed 0-1500rpm, grinding capacity 30-100L, using zirconia grinding medium and chill down jacket design, temperature rise is small, easy to operate.

$ 5721.00

Using frequency conversion brushless motor, Rotation speed up to 8000RPM, Electric lift Travel 300mm, brushless abrasion, can handle high viscosity materials, provide stable shear rate.

$ 1122.00

Adopt double grinding head linear friction mode, load 570 +/- 20g adjustable, working plate Rotation speed 0~ 135rpm, magnetic chuck design makes sample loading and unloading convenient, the counter directly reads the number of sanding.

$ 696.00

Using pure mechanical design, the coating performance is measured by conical mandrel bending test plate, the test plate size is 100mm × 180mm, the thickness is less than or equal to 0.8mm, and the operation is simple and reliable.

$ 240.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Technical Details of Measuring Paint Contrast Ratio Using Black-and-White Checkerboard Method with Hiding Power Card
This article introduces a method for measuring the hiding power of coatings using black and white checkerboard paper.