Aluminum wire eddy current flaw Detector

The aluminum wire eddy current flaw detector induces eddy currents on the surface of the aluminum wire through an alternating magnetic field and detects changes in the eddy currents to identify defects such as cracks and inclusions. It is used for real-time quality monitoring on aluminum production lines to ensure material integrity.
Selection
When selecting, consider matching the aluminum wire diameter with the probe size, aligning the detection speed with the instrument's frequency response, determining the display method based on the defect type, accounting for the impact of environmental temperature on sensor stability, and ensuring the output interface is compatible with existing equipment.

Terms

Instruments

With a wide frequency range of 64Hz-2MHz, it can detect longitudinal crazing and transverse defects, adapts to a variety of Probe types, supports automatic phase analysis and zero correction functions, and is suitable for high-speed inspection environments.

$ 7335.00

The eddy Current principle is used for measurement of nonconductive coatings on non-ferrous metal substrates, with a thickness range of 0~ 625μm and an error of +/- 3%. It has IP65 Protection Rating and fast measurement capabilities of more than 60 readings per minute.

$ 1338.00

Using eddy current sensing principle and probe probe design, especially suitable for small size and profiled material measurement; Measurement range 0-1500 μm, resolution up to 0.1 μm, repeatability error ≤ +/- ( 0.8% reading + 0.1 μm), support multi-point calibrating and data statistics function.

$ 612.00

Frequency range 50Hz~ 12MHz, gain 0~ 90dB continuously adjustable, with relatively independent test channels and a variety of Display modes.

$ 8949.00

Using eddy Current thickness measurement principle, Measurement range 0-1000μm, resolution 0.1μm, minimum measurable convex curvature 3mm, with automatic shutdown and low voltage prompt function.

$ 267.00

Using 64Hz-2MHz broadband range, it can detect vertical crazing and horizontal defects, with automatic zero correction system and sound and light alarm function, and supports a variety of Probe adaptations.

$ 10401.00

Using magnetic Induction and eddy current double thickness measurement method, Measurement range 0-1250μm, error +/- 3%, automatic identification of iron and non-iron matrix, with statistical function and undervoltage indication, easy to operate.

$ 180.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-3000μm, accuracy +/- 3%, automatically identify the matrix material, no need to calibrate only zero, easy to carry and lightweight.

$ 787.00

Eddy current induction technology to ensure good Repeatability and accuracy, support six kinds of Hardness standard automatic switching, single charge can be continuous measurement of more than 5000 times, thickness Measurement range 0.6mm-8mm.

$ 264.00

Using magnetic Induction and eddy Current dual technology, Measurement range 0-1500μm, accuracy +/- 2%, Probe wear resistance more than 500,000 times, support single point and multi-point calibrating, suitable for various environments.

$ 306.00

Using magnetic Induction and eddy Current Dual Measuring method, Measurement range 0~ 3000μm, accuracy +/- 2%, Probe wear resistance more than 500,000 times, Measurement speed of 0.3 seconds/time, suitable for various matrix materials.

$ 323.00

Using eddy Current Measurement principle, Measurement range 0~ 1250μm, with continuous single double Measurement mode, metal shell anti-interference, support automatic statistics and storage of 1560 measured values.

$ 344.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 1250μm, resolution up to 0.1μm, equipped with wear-resistant hard metal probe and spring guide sleeve Probe, support automatic memory calibrating and RS232C communication.

$ 354.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 500um, resolution 0.1μm, wear-resistant hard metal probe and Automatic calibration function, support single and continuous Measurement mode.

$ 275.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 1250μm, Probe with line can measure grooves and complex positions, automatically identify iron and non-iron substrates, with single point and two point Adjustment.

$ 196.00