Fixed pump-suction gas Detector

A fixed pump-suction gas detector actively draws ambient gas through a built-in pump and analyzes the concentration of target gases via sensors. It is used for continuous monitoring of gas leaks in pipelines, confined spaces, and other areas, ensuring production safety in industries such as chemical and oil and gas.
Selection
When selecting, consider the compatibility of the detection gas types and ranges with on-site requirements. The pump suction flow rate must meet the sampling distance. Sensor lifespan and anti-interference capability impact maintenance cycles. The protection rating should suit the installation environment, and the output signal type must be compatible with the control system.

Terms

Standards

Instruments

Pump-suction sampling and imported Electrochemical sensor, Response Time ≤ 20 seconds, resolution 0.01ppm, support 1-5 Sensor expansion, IP65 Protection Rating, suitable for harsh environments.

$ 754.00

Using pump-suction sampling and imported Electrochemical sensor, Response Time ≤ 20 seconds, detection accuracy ≤ +/- 3%, support 1-4 Sensor expansion, Protection Rating IP65 for harsh environments.

$ 527.00

Pump suction sampling, Response Time T90 ≤ 20s, can store 120000 sets of data, equipped with 2.4 inch color screen display concentration value, support Humidity detection and data export function.

$ 545.00

Maximum 4 kinds of gas simultaneous detection, integrated temperature and Humidity compensation, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Protection Rating IP66, suitable for a variety of Installation methods.

$ 693.00

Pump-suction sampling and a variety of detection principles, Response Time ≤ 20 seconds, accuracy ≤ +/- 3%, built-in 3800mAh battery, support 120,000 sets of Data storage and Temperature Humidity detection.

$ 527.00

Supports simultaneous detection of 4 gases and integrated temperature Humidity monitoring, adopts pump suction and diffusion double Sampling method, has IoT remote monitoring function, Protection Rating IP66, Operating temperature range -40~ 55 ℃.

$ 1050.00

Pump-suction Sampling method, detection accuracy ≤ +/- 3%, resolution of 0.01ppm, Response Time T90 ≤ 20 seconds, built-in large-capacity battery, support for multi-Sensor expansion, with IP65 Protection Rating.

$ 432.00

Support 4 kinds of gas detection at the same time, integrated Humidity monitoring function, dual temperature Humidity compensation design, with 10 Meters visual distance high definition color screen, Protection Rating up to IP66, Operating temperature range -40~ 55 ℃.

$ 819.00

Pump suction sampling, Response Time T90 ≤ 20 seconds, detection accuracy ≤ +/- 3%, built-in 4000mAh battery, support 120000 data storage, IP65 Protection Rating, suitable for a variety of industrial environments.

$ 412.00

The 2900ma large-capacity lithium battery can work for 20 hours, equipped with 2.4-inch high definition color screen and 16-bit data collection chip, supports one-button switching between PPM and mg/m3 units, and has triple alarm function of sound, light and vibration.

$ 687.00

The device supports simultaneous detection of 4 gases and integrates temperature and Humidity monitoring, adopts physical + software double repetition Humidity compensation, Response Time T90 ≤ national standard, has a variety of wireless communication options and remote paraMeter configuration functions, and is suitable for complex industrial environments.

$ 716.00

Pump suction sampling, Response Time T90 ≤ 20 seconds, detection accuracy ≤ +/- 3%, support 1-4 Sensor expansion, with dust Filter to adapt to harsh occasions.

$ 774.00

Supports simultaneous detection of 4 gases, integrated temperature and Humidity compensation, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Protection Rating IP66, suitable for a variety of Installation methods.

$ 693.00

Supports simultaneous detection of 4 gases and integrated temperature Humidity monitoring, compatible with pumping and diffusion Sampling method, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Operating temperature range -40~ 55 ℃.

$ 743.00

Pump sampling ensures fast detection speed, can store 100000 data, support buzzer and LED dual alarm. Explosion-proof level EXia II CT6, Battery capacity 2800mAh, working life 10-60 hours.

$ 254.00

Articles

The effect of the substrate fixing method on coating uniformity in a vacuum adsorption blade coating tester.
This article discusses the impact of different substrate fixing methods on coating uniformity in a vacuum-assisted knife-over-roll coating tester. It compares four methods—vacuum adsorption, electrostatic adsorption, mechanical clamping, and adhesive fixing—focusing on their mechanical principles and limitations.
Effect of Different Coating Speeds on Film Thickness Consistency in an Adjustable Film Applicator
This paper studies the influence of coating speed of an adjustable film applicator on film thickness uniformity. In the experiment, the coating blade gap was fixed at 100 μm, and a resin solution with a viscosity of 200 mPa·s was used to prepare films at five speeds ranging from 10 to 80 mm/s, followed by thickness measurements.
Pencil hardness tester rapidly evaluates scratch resistance of paint film.
This article introduces how to quickly assess the scratch resistance of paint films using a pencil hardness tester. During the test, standard pencils (ranging from 6B to 9H) are used to scratch the coating at a fixed angle and pressure to observe whether scratches occur.
Standard ink film preparation with a blade coater before tack testing of offset printing inks.
This article introduces the method of preparing a standard ink film using a blade coater before testing the tackiness of offset printing inks. It explains the principle of controlling ink film thickness by adjusting the blade gap and details the operational steps from securing the substrate and applying the ink to completing the coating process.
Heat Deflection Temperature Tester for Measuring the Thermal Resistance of Carbon Fiber Reinforced Plastics
This article introduces the method of testing the heat resistance of carbon fiber-reinforced plastics using a heat deflection temperature tester. The instrument applies a fixed load to the material while increasing the temperature, measuring the temperature at which the material reaches a specified deformation, thereby evaluating its short-term resistance to thermal deformation.
Vicat Softening Point Tester measures the heat resistance of plastics.
This article introduces how a Vicat softening point tester measures the heat resistance of plastics. During the test, the instrument applies a fixed load to the plastic sample and heats it at a constant rate. When the flat-ended needle penetrates the sample to a depth of 1 millimeter, the temperature at that moment is recorded, which is known as the Vicat softening point.
Heat Sealing Tester Determines the Optimal Heat Sealing Temperature for Films
A heat seal tester is used to determine the optimal heat sealing temperature of films to ensure the sealing strength and integrity of packaging. During testing, by setting a temperature gradient and fixing parameters such as pressure and time, samples are heat-sealed at different temperatures, and then their strength is measured.
Differential pressure method gas permeameter measures oxygen transmission rate of films.
This article introduces the method of measuring the oxygen transmission rate of films using the differential pressure gas permeation apparatus.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Circle Method Adhesion Tester for Evaluating the Adhesion of Paint Coatings by the Circular Rolling Line Method
The rolling circle method is a technique for testing the adhesion of paint coatings using a circle-drawing instrument. The instrument employs a fixed-load stylus to draw a continuous circular trace on the coating at a constant speed, and the adhesion level is assessed based on the peeling condition of the scratch.
Pencil Hardness Plan Outstanding Paint Film Pencil Hardness Grade
The pencil hardness test is a method for evaluating the scratch resistance of paint films. It involves using a series of pencils with known hardness levels to scratch the coated surface under fixed conditions. The hardness grade of the coating is determined by observing whether permanent scratches are produced.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.