Mirror stainless steel liner and tube flow circulating fan, Humidity control accuracy, high temperature fluctuation +/- 0.5 ℃, support 99 cycles, each section of 99 hours, to ensure experimental uniformity and Reliability.
Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.
The equilibrated refrigeration technology makes the temperature fluctuation small, and the fluorine-free R134 refrigerant is more energy-saving and environmentally friendly. Temperature range 0~ 60 ℃, Humidity Control Range 50~ 90%, intelligent humidification system and mirror stainless steel liner.
Temperature range -5~ 80 ℃, Humidity deviation +/- 3% RH, mirror stainless steel liner and JAKEL circulating fan to ensure Temperature uniformity, support 99 cycle complex experimental procedures.
Temperature resolution up to 0.1 ℃, Humidity Control Range 60~ 85% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure experimental safety.
Using imported Sensor and TMHM equilibrating Conditioning method, temperature control accuracy of +/- 0.5 ℃, humidity control accuracy of +/- 3% RH, with independent temperature limit alarm system to ensure experimental safety.
Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.
Adopt multi-stage programmable PID controller to achieve accurate temperature and Humidity control, with small fluctuations; unique air duct circulation system to ensure uniform temperature and Humidity; with 100 sets of programs and 1000 segments capacity, support RS-232 or RS-485 communication interface, easy data monitoring and remote operation.
Humidity Control Range 80~ 95% RH, Temperature resolution 0.1 ℃, Humidity deviation +/- 3% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safety.
Adopt mirror stainless steel liner and PID Control mode, Temperature range 0~ 60 ℃, Humidity deviation +/- 5~ 8% R.H., 99 cycle programs and independent temperature limit alarm system.
The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.
Mirror stainless steel liner is easy to clean, Temperature range -5~ 80 ℃, humidity control 40~ 85% RH, equipped with independent temperature limit alarm system to ensure experimental safety, optional printer to record paraMeter changes.
Temperature range 10~ 85 ℃, humidity control 80~ 95% RH, fluorine-free environmental protection design, with independent temperature limit alarm system, mirror stainless steel liner easy to clean, Temperature resolution 0.1 ℃, stable and reliable operation.
Imported Humidity Sensor and Compressor, temperature control accuracy of +/- 0.5 ℃, humidity deviation +/- 3% RH, equipped with independent temperature limit alarm system and test hole to ensure the safety and reliability of the experiment.
Adopt equilibrated refrigeration technology, with small temperature fluctuations, equipped with automatic defrosting function; fluorine-free R134 refrigerant is more energy-saving and environmentally friendly; mirror stainless steel liner, adjustable shelf; microcomputer PID control, Humidity Accuracy +/- 0.1 ℃.