Cooling circulation cryopump

The cooling circulation cryopump transfers heat through the refrigerant compression cycle, enabling the equipment to operate under constant temperature conditions. It is used for cooling laboratory instruments, such as rotary evaporators and reaction vessels, to maintain samples at low temperatures.
Selection
When selecting, consider matching the refrigeration temperature range with the equipment requirements, pay attention to the corrosion resistance of the pump body material, ensure the circulation flow rate meets heat exchange needs, account for the impact of ambient temperature on cooling efficiency, and verify that the interface size is compatible with the equipment.

Terms

Standards

Instruments

Temperature control accuracy of +/- 2 ℃, cooling capacity up to 3240W, equipped with fully enclosed Air-Cooled Compressor and anti-corrosion circulation system, rapid temperature rise and fall, support large capacity Bath and external circulation function.

$ 3151.00

The use of non-heat centrifugal circulation pump to avoid affecting the temperature field, Temperature Uniformity of +/- 0.05 ℃, support 200 degrees of high temperature directly start cooling, domestic circulation system to achieve a high degree of uniformity in the flow field, to ensure a stable liquid environment.

$ 6902.00

Adopt non-heat centrifugal circulation pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity of +/- 0.05 ℃, support 200 degrees high temperature direct start cooling without damaging the Compressor, equipped with 13L/min external circulation Flow rate.

$ 3854.00

Adopt non-heat centrifugal circulation pump to avoid its own heat pRoduction, Temperature Uniformity +/- 0.05 ℃, support 200 degrees high temperature direct start cooling without damaging the Compressor, equipped with 13L/min external circulation Flow rate to ensure stable insulation field.

$ 2671.00

Adopting 5 inch Touchscreen integrated display, PID intelligent temperature control technology automatically sets paraMeters, Compressor unit cooling and cooling quickly, domestic circulation makes the temperature uniform, external circulation can establish external thermostatic field, slot volume 6L.

$ 985.00

Temperature range covers -50 to 200 ° C, supports 200 ° C direct start cooling without damaging the Compressor; uses a heat-free centrifugal circulation pump and U-shaped return design to ensure Temperature Uniformity +/- 0.05 ° C; provides a variety of Safety protection such as low water level and temperature runaway alarm.

$ 2044.00

The use of domestic circulation to ensure uniform and constant temperature, external circulation pump can lead the liquid outside the Tank heating, temperature control accuracy +/- 0.1 ℃, Temperature Fluctuation +/- 1 ℃, LED dual window digital display, insulation layer efficient, Benchtop structure small size.

$ 1080.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with multiple Safety protection devices including power-off protection and temperature runaway alarm to ensure the stability and safety of the experimental process.

$ 2241.00

Temperature range -10~ 100 ℃, temperature control accuracy +/- 0.2 ℃, support multi-stage programming and internal and external circulation, provide over-temperature and low temperature sound and light alarm and liquid level protection.

$ 1450.00

Temperature Uniformity of +/- 0.05 ℃, can be directly started at 200 ℃ high temperature refrigeration, no heat centrifugal circulation pump to avoid affecting the temperature field, support 13L/min external circulation Flow rate.

$ 4679.00

Temperature range -20~ 20 ℃, cooling capacity up to 1800W, cooling time is reduced by 35% compared with traditional equipment, open Bath can be applied to acid solution and organic solution thermostatic experiment.

$ 1658.00

Temperature control accuracy of +/- 0.1 ℃, temperature fluctuation of +/- 1 ℃, equipped with domestic circulation to ensure uniform temperature, external circulation pump can lead liquid heating, LED double window digital display easy to operate, thermal insulation material efficient, Benchtop compact structure.

$ 911.00

Temperature control accuracy +/- 2 ℃, refrigeration capacity up to 1250W, equipped with fully enclosed Air-Cooled Compressor and anti-corrosion circulation system, fast temperature rise and fall, can be used as a freezer Tank and provide external circulation of frozen liquid.

$ 929.00

The non-heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, 4300W cooling capacity to ensure stable operation of the equipment, with multiple Safety protection functions.

$ 2644.00

The non-heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.05 ° C, supports 13L/min external circulation Flow rate, and has multiple Safety protection such as power failure and temperature runaway.

$ 1613.00

Articles

The main difference between the high-low temperature test chamber and the constant temperature and humidity test chamber
This article mainly distinguishes between high-low temperature test chambers and constant temperature and humidity test chambers.
Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.