Painter's Mixing Machine

Paint mixers, driven by motors, rotate blades to uniformly blend solid particles with liquids in coatings, preventing sedimentation and clumping. They are used on-site to adjust the viscosity of coatings, ensuring consistent color and texture during application. Commonly employed in construction, renovation, and industrial coating preparation.
Selection
Select the motor power based on the viscosity of the coating; high viscosity requires high-torque models. The length of the mixing rod should match the container depth, and the blade shape should suit materials with different flow properties. Consider portability requirements and power source types, and ensure the protection rating is suitable for the on-site environment.

Terms

Standards

Instruments

The device can quickly mix ground dispersed materials in a closed system, with a speed range of 1500-3500 rpm, a mixing capacity of 5-150G, and features bubble-free and quiet operation.

$ 6205.00

The non-contact mixing method is adopted to avoid sample contamination, the speed range is adjustable from 0 to 2800rpm, and various containers such as testtube beakers are supported. The mixing efficiency is dozens of times higher than that of manual mixing, and the mixing is uniform.

$ 127.00

Adopt closed system design, mixing capacity 5-200G, Speed range 1500-3500rpm, can achieve fast and efficient Mix & disperse, the operation process is quiet, pollution-free and bubble-free, support manual and intelligent two control modes.

$ 6851.00

Made of stainless steel, the diaMeter of the slurry is 60mm, and the diaMeter of the Rod is 8mm. It is suitable for efficient mixing of medium and low viscosity liquids. The structure is simple and durable, and the mixing effect is uniform and stable.

$ 96.00

Adopt Rotation Rotation Rotation Noncontact Mixing & dispersing method, Rotation Rotation ratio 1:0.7, Processing capacity up to 700ml, can complete defoaming stirring in a few seconds to a few minutes, No need to clean appliances, Repeatability is high.

$ 3301.00

The linear velocity of blade disk is 10.5 m/s, the volume of material barrel is 1.8 L, and the aggregates are destroyed by strong impact and shearing to achieve high-efficiency dispersion and mixing, which is suitable for liquid material experiments.

$ 1171.00

Mixing method of low speed intermittent sticking barrel edge, professional Impeller design, can be thoroughly stirred in 10 minutes without heating up, Speed range 0~ 50rpm adjustable, easy to replace stainless steel Mixing Tank.

$ 4592.00

Made of stainless steel, with a diaMeter of 60mm and a Rod length of 300mm, it is suitable for efficient mixing of medium and low viscosity liquids. Medium and high speed operation provides stable mixing effect.

$ 94.00

High frequency vibration vortex to achieve uniform mixing, speed range 0-2800rpm, support point and continuous operation mode, no need to add magnetic components to avoid sample contamination, suitable for rapid mixing of various containers.

$ 183.00

Adopt biaxial planetary motion structure, revolution 0-70rpm and rotation 0-80rpm adjustable, equipped with automatic wall scraping device to achieve no dead point mixing, Total Power 6.75kw to meet a variety of material handling needs.

$ 7303.00

Made of stainless steel, with a diaMeter of 50mm and a Rod length of 300mm, it is suitable for medium and low viscosity mixing, and medium and high speed stirring pRoduces uniform flow.

$ 96.00

Double-decked construction design with a capacity of 1.5 liters, suitable for a variety of Power Dispersers, providing stable mixing support.

$ 117.00

The pumping rate is up to 4L/s, and the noise value is only 68dB. The gas ballast valve design is adopted to prevent the pump oil from mixing and prolong the service life. It is compact and easy to install, and supports a variety of interface conversions.

$ 361.00

Max. stirring Capacity 1000mL, Speed range 0-1600rpm, using magnetic field drive technology implementation of non-contact stirring, suitable for a variety of low viscosity liquid mixing needs.

$ 107.00

Integrated mixing oscillation incubate three functions, temperature accuracy +/- 0.5 ℃, speed 200-1800rpm, metal module anti-pollution, support multi-point operation and timing operation.

$ 1437.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Technical Details of Measuring Paint Contrast Ratio Using Black-and-White Checkerboard Method with Hiding Power Card
This article introduces a method for measuring the hiding power of coatings using black and white checkerboard paper.