Low-temperature thermostatic circulation pump

The low-temperature constant temperature circulation pump combines a refrigeration system with circulating fluid to maintain a set low-temperature environment and circulate fluid, which is used for temperature control of laboratory reactors, spectrometers, and other equipment to ensure stable experimental conditions.
Selection
When selecting, consider the temperature range, cooling power, pump flow rate and pressure, tank capacity, temperature control accuracy, medium compatibility, and environmental adaptability to match specific experimental requirements and equipment specifications.

Terms

Standards

Instruments

The use of domestic circulation to ensure uniform and constant temperature, external circulation pump can lead the liquid outside the Tank heating, temperature control accuracy +/- 0.1 ℃, Temperature Fluctuation +/- 1 ℃, LED dual window digital display, insulation layer efficient, Benchtop structure small size.

$ 1080.00

Temperature control accuracy of +/- 0.1 ℃, temperature fluctuation of +/- 1 ℃, equipped with domestic circulation to ensure uniform temperature, external circulation pump can lead liquid heating, LED double window digital display easy to operate, thermal insulation material efficient, Benchtop compact structure.

$ 911.00

Temperature control accuracy +/- 0.1 ℃, domestic circulation direct test, external circulation provides thermostatic medium through high voltage pump, with LED display and multiple Safety protection, motor and circulation pump low heat efficiency.

$ 951.00

Water and oil dual-use optional room temperature to 100 ℃ range, external circulation function to establish a second thermostatic field, Temperature Uniformity +/- 0.05 ℃, domestic circulation without heat centrifugal pump to avoid the impact of temperature field, Safety protection including power failure and low water level alarm.

$ 1058.00

Adopt non-heat circulating pump to avoid the traditional pump's own heat generation affecting the tank temperature; fully enclosed compressor unit refrigeration, with overheating and overcurrent multiple protection; display accuracy 0.1 ° C, temperature control accuracy +/- 0.1 ° C; 304 stainless steel liner anti-corrosion; circulation interface and drain port use pagoda connector, fast installation.

$ 1138.00

The maintenance-free pressure pump is resistant to fiber metal particles, supports domestic circulation with sample Cup bracket and external circulation Viscometer jacket thermostatic, temperature control accuracy +/- 0.01 ℃ and low liquid level protection function.

$ 2087.00

With the function of water-oil dual-use, Temperature Uniformity up to +/- 0.05 ℃, no heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field and support the establishment of a second thermostatic field for external circulation.

$ 564.00

Temperature range -30~ 25 ℃, Temperature Stability +/- 2 ℃, equipped with fully enclosed Air-Cooled Compressor and anti-corrosion circulation system, high temperature lifting speed, can provide large Flow rate circulation and multi-functional low temperature operation support.

$ 2541.00

The non-heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field, and the porous U-shaped return design realizes a high degree of uniformity, Temperature Uniformity +/- 0.05 ℃, and supports the establishment of a second thermostatic field for external circulation.

$ 1209.00

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, no heat centrifugal circulation pump to avoid its own heat generation affecting the temperature field, support external circulation to establish a second thermostatic field, built-in multiple Safety protection devices.

$ 798.00

Equipped with a strong pressure suction pump to provide a thermostatic source for the peripheral Tank, temperature accuracy +/- 0.1 ℃, over-temperature and low temperature sound and light tracking alarm and liquid level protection functions ensure the safety and reliability of the sample.

$ 877.00

Adopt high-performance non-heat circulating pump to avoid traditional pump self-generated heat; Temperature control accuracy of +/- 0.1 ℃, Temperature range -40~ 100 ℃; with power-off protection, over-temperature alarm, low level air burning protection and other multiple safety functions to ensure stability and reliability.

$ 2150.00

Equipped with a strong pressure suction pump can provide a thermostatic source for the peripheral Tank, with a temperature accuracy of +/- 0.1 ° C, with over-temperature and low temperature sound and light alarm and liquid level protection functions to ensure the safety and reliability of the sample.

$ 1098.00

Proportional refrigeration technology and high temperature direct drop technology, Temperature range -80~ 40 ℃, cooling capacity 400W, built-in pressure suction pump, Flow rate 12L/min, support short time idling and impurity resistance.

$ 4677.00

Adopt proportional refrigeration technology and high temperature direct drop technology, temperature fluctuation +/- 0.1 ℃, pump maximum Flow rate 22L/min, support short time idling and low liquid level protection, long service life.

$ 2136.00

Articles

The main difference between the high-low temperature test chamber and the constant temperature and humidity test chamber
This article mainly distinguishes between high-low temperature test chambers and constant temperature and humidity test chambers.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.