FluoroMeter Fluorescence SpectroPhotoMeter

A fluorometer excites a sample with a light source to produce fluorescence, and a detector measures the fluorescence intensity. A fluorescence spectrophotometer adds a monochromator to isolate specific wavelengths, enabling the analysis of substance concentration and composition. It is applied in areas such as ink composition detection and plastic additive analysis.
Selection
Select the excitation and emission wavelength ranges based on the fluorescence characteristics of the sample. Consider the match between detection sensitivity and sample concentration. Pay attention to the wavelength accuracy and stability of the instrument. Choose a solid holder or liquid cuvette accessory according to the sample morphology.

Terms

Standards

Instruments

Equipped with a long working distance flat-field color difference elimination objective lens and four sets of fluorescence filters, it supports phase contrast observation and fluorescence switching, and the fretting grid value is up to 2 μm, which is suitable for clear imagery of living cells and liquid samples.

$ 10207.00

Infinity Optical inspection system, support for Brightfield, Fluorescence, Phase Contrast, Polarization Observation mode; equipped with six-hole converter with DIC slot and 100W mercury lamp light source, providing high-resolution images; autofocus system to maintain sample focal plane stability.

$ 28652.00

Continuous zoom range 7X~ 63X, working distance up to 110mm, equipped with Process Color LED fluorescence excitation assembly and hinged trinocular observation head, support a variety of fluorescence Observation modes.

$ 3268.00

The width is 5cm, the optical path is 10mm, and the dimensions are 12.5 × 52.5 × 45mm, which is suitable for the use of Spectrophotometer to ensure Optical inspection detection accuracy.

$ 114.00

Width 2cm, optical path 10mm, dimensions 12.5 × 22.5 × 45mm, specially designed for Spectrophotometer matching Cuvette, to ensure Optical inspection detection accuracy.

$ 101.00

The width is 3cm, the optical path is 10mm, and the dimensions are 12.5 × 32.5 × 45mm. As a special accessory for Spectrophotometer, it ensures the stability of the optical path and the accuracy of measurement.

$ 106.00

Optical inspection fluorescence technology for measurement of dissolved oxygen, no polarization time, fast Response and not affected by Flow velocity; Built-in temperature sensor, Measurement range 0.00-50 mg/L, accuracy up to 1.5% +/- 0.01mg/L; Protection Rating IP68, suitable for harsh environments.

$ 3401.00

Using fluorescence measurement technology without replacing the diaphragm and electrolysis solution, Measurement range 0.000~ 20.00mg/L accuracy +/- 0.20mg/L, support 3000 sets of Data storage and interval timing measurement, IP57 Protection Rating.

$ 1033.00

Optical inspection system with infinity, long working distance objective lens such as 10X0.25 working distance 4.3mm, swirl/spin swing-out concentrating system can observe high culture dishes without contamination, Modular fluorescence system is easy to adjust.

$ 10530.00

Optical inspection fluorescence method without reference solution, built-in temperature sensor to calibrate data in real time, dual range design covering 0~ 20mg/L and 0~ 200% Saturation, 10 Meters long cable to support deep water or remote installation, polyformaldehyde and stainless steel composite structure to enhance environmental adaptability.

$ 636.00

It adopts coaxial focusing mechanism with coarse fretting, with a fretting grid value of 2 μ m, equipped with 100W high voltage mercury lamp fluorescent epiphany illumination and 6V 20W halogen lamp transmission illumination, and supports B excitation light band 420~ 485nm and G excitation light band 460~ 550nm.

$ 2575.00

Optical inspection system and Modular design, equipped with flat-field color difference elimination fluorescent objective, fretting grid value of 2 μ m, support multi-band fluorescent filter group, comfortable operation.

$ 4688.00

Optical inspection system with infinite distance, equipped with flat-field color difference eliminating fluorescent objective, fretting grid value of 2 μ m, coarse fretting coaxial focusing, support for a variety of fluorescent filter sets, suitable for low-illumination microscopic image shooting.

$ 4398.00

Optical inspection system with infinity and Modular function design, equipped with flat-field color difference-cancelling fluorescent objective, with a fretting grid value of 2 μm, supports a variety of excitation bands of fluorescent filter sets to meet the needs of scientific research and observation.

$ 3753.00

Can measure ISO whiteness and fluorescence whiteness, Repeatability ≤ 0.02, support data cache and power-off protection, equipped with RS232 interface for easy communication, suitable for powder and flake samples.

$ 953.00

Articles

Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of UV Spectrophotometer in the Determination of Lignin in Pulp
This article introduces the application of ultraviolet spectrophotometry in determining the lignin content in pulp. Lignin is a key component affecting pulp quality. This method utilizes the characteristic absorption of lignin under ultraviolet light for measurement, offering simple and rapid operation.
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.
Guide to Avoiding Pitfalls When Purchasing a Spectrophotometer
When selecting a spectrophotometer, it is essential to first understand its working principle based on the Lambert-Beer law, as this helps in assessing the rationality of the instrument's design.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
Key Technical Points for Determining Arsenic and Mercury in Water Using Atomic Fluorescence Spectrophotometry
This article introduces the key techniques for determining arsenic and mercury in water using an atomic fluorescence spectrometer. The experiment requires attention to safety precautions, regular maintenance of the instrument, and proper disposal of waste liquids.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.
Phosphor films and quantum dot coatings are uniformly applied using a coating machine.
This article introduces the significance of phosphor films and quantum dot coatings in optoelectronics and display technologies, highlighting that their performance depends on the uniformity, thickness, and density of the coatings.