Micro-volume Melting Point Apparatus

The micro melting point apparatus determines the melting point of a substance by heating the sample and observing its transition temperature from solid to liquid. It is used to ascertain the melting point, assess purity, or identify substances. It finds applications in chemical, pharmaceutical, and materials analysis.
Selection
When selecting, consider that the temperature range covers the sample's melting point, the heating rate is adjustable, the sample amount is small, the operation is simple, and the data is accurate. Ensure the instrument is stable and durable, complies with industry standards, and meets daily testing needs.

Terms

Standards

Instruments

Using 0.5-2 μL micro-volume sample detection, the optical path accuracy is 0.001mm, the detection concentration is 50 times that of conventional equipment, and the sample recovery and 6-second rapid analysis are supported.

$ 7416.00

With five linear heating rate setting, Temperature range RT + to 400 ℃, resolution 0.1 ℃, support capillary method and coverslip method measurement, high magnification microscopic observation of melting details, suitable for a variety of Sample types.

$ 988.00

It can process 4 samples at a time, realize one-button measurement function, Temperature range RT +~ 400 ℃, heating rate 0.1~ 20 ℃ stepless adjustable, automatic recording of melting distance, initial melting and final melting, with 10 sets of spectrum storage and 400 Data storage capacity.

$ 3172.00

Using photoelectric automatic detection and PID adjustment technology, temperature range RT +~ 300 ℃, resolution 0.1 ℃, can automatically calculate the average melting point and record the melting Linear dispersion, support three capillary tubing simultaneous measurement.

$ 2397.00

Using PID system control and High Accuracy temperature sensor, Temperature range RT +~ 350 ℃, melting point Test accuracy is the highest +/- 0.5 ℃, heating rate 3.0 ℃ -5 ℃/min, to ensure stable and efficient testing.

$ 654.00

With five linear heating rate control, Temperature resolution of 0.1 ℃, support capillary method and coverslip method Measurement mode, high power microscopic observation is suitable for dark, low purity and analysis samples.

$ 859.00

Using photoelectric detection technology to automatically identify the initial and final melting points, equipped with Platinum Resistance Sensor to ensure +/- 0.5 ℃ accuracy, support eight linear heating rate and automatic storage function, no manual monitoring can complete the measurement.

$ 1116.00

Support capillary tubing and hot stage two measurement methods, temperature range RT +~ 320 ℃, Microscope 40 times magnification observation, sexual repeability +/- 1 ℃ (≤ 200 ℃), to meet the melting point of crystalline organic compounds determination needs.

$ 624.00

Using high-resolution video technology instead of traditional Microscope, it can process 4 samples at a time, Temperature range RT +~ 350 ℃, accuracy +/- 0.1 ℃, support powder and bulk sample measurement, automatic recording of melting range data.

$ 4414.00

High Accuracy temperature control technology, Temperature range RT +~ 400 ℃, resolution 0.1 ℃, support 0.1~ 20 ℃ stepless heating, high-resolution video observation melting process, no map but can store 400 data.

$ 2607.00

Using photoelectric automatic detection and PID adjustment technology, temperature range RT +~ 320 ℃, resolution 0.1 ℃, automatically display the initial and final melting and record the melting Linear dispersion, improve measurement accuracy and reliability.

$ 1526.00

Using PID temperature control technology to ensure accurate and stable temperature, temperature resolution of 0.1 ℃, support capillary method and hot table method two measurement methods, microscopic camera real-time display of melting process, data can be stored and transmitted.

$ 1521.00

Equipped with a high definition camera module can clearly observe the sample melting process, process 4 samples at a time, Temperature range RT +~ 420 ℃, heating rate 0.1~ 20 ℃ infinitely adjustable, automatic recording of melting distance and initial melting and final melting.

$ 5754.00

Using photoelectric detection technology automatic measurement melting point, accuracy of +/- 0.2 ℃, support eight linear heating rate and platinum resistance Sensor, without manual monitoring can work stably.

$ 1190.00

With photoelectric detection and automatic measurement function, Temperature range RT +~ 320 ℃, resolution 0.01 ℃, eight linear heating rate optional, support melting Linear dispersion recording and average calculation.

$ 1501.00

Articles

Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Repetibility Test Method and Weights for Semi-micro Balances
This article discusses the method for repeatability testing of semi-micro balances and the use of weights. Repeatability refers to the consistency of the balance's results when weighing the same object multiple times under the same conditions, which is crucial for the reliability of experimental data.
Analysis of Causes for Excessive Repetition Error in Microbalances
Microbalance repeatability out-of-tolerance refers to the situation where the results of multiple weighings of the same object exceed the allowable range of variation.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Differential Scanning Calorimetry for Determining the Melting Point and Glass Transition Temperature of Hot Melt Adhesives
This article introduces the method of determining the melting point and glass transition temperature of hot-melt adhesives using a differential scanning calorimeter. Differential scanning calorimetry analyzes the thermal transition characteristics of materials by measuring the energy difference between the sample and a reference material.