Multi-coating head test coater

The multi-coating head test Coater applies different coatings onto a substrate simultaneously or sequentially through multiple independent coating units. Mechanisms such as blades and rollers are used to control the coating thickness, simulating the production coating process. It is used in laboratories to test coating compatibility, interlayer effects, and validate process parameters.
Selection
When selecting, consider the matching of substrate width with the number of coating heads, and ensure the coating thickness adjustment range covers experimental requirements. Pay attention to the coordination between the drying system and coating speed, and ensure the material corrosion resistance is suitable for the chemicals used. The operation interface should be intuitive for easy parameter adjustment, and maintenance components must be easy to disassemble and clean.

Terms

Standards

Instruments

Support multi-coating system measurement, can measure up to 3 Coating thickness, Measurement range 13~ 1000μm, error +/- (3% H + 2) μm, with 100000 data storage capacity and a variety of Data output methods.

$ 3462.00

Measurement range 50-3800 microns, high contrast ratio color LCD display, wireless connectivity and data synchronization, ASTM D6132 and ISO 2808 compliant.

$ 3724.00

Adopt clamshell type Blade Coating head design, easy to clean; coating speed 1~ 300mm/s stepless speed regulation, Spreader accuracy up to +/- 0.003mm, to meet the laboratory High Accuracy film needs.

$ 2978.00

The Spin Coater is controlled by touch screen, the acceleration range is 100~ 4000rpm/s, and the speed can be automatically corrected by A/K selection. The motor torque is large and the operation is smooth, which is suitable for the assembly line process.

$ 2494.00

Adopt clamshell type Blade Coating head design, easy to clean; Spreader accuracy up to +/- 0.003mm, film thickness control precision; coating speed stepless speed regulation, application length can be adjusted freely, suitable for High Accuracy Laboratory Moulding needs.

$ 6528.00

Using ultrasonic technology implementation nondestructive measurement, Measurement range 13~ 1000μm, accuracy +/- 3%, support multi-coating system analysis, with weatherproof protection and a variety of data transmission methods.

$ 2855.00

Using drawdown blade and roller coating double Spreader head device, Spreader thickness range of 0.005-3mm, drying temperature up to 200 ℃, with automatic correction and precision thickness adjustment function.

$ 22665.00

The multi-groove coating scraper can scrape 10 wet-films of different thicknesses at one time, the thickness difference of adjacent films is 25um, and the wide film thickness range of 50-675um is supported. It is convenient to visually observe the sag situation by placing the test plate vertically.

$ 315.00

Using ultrasonic technology implementation nondestructive measurement, Measurement range 50~ 7600 μ m, accuracy +/- 3%, with weatherproof design and support for multi-coating system analysis, built-in statistical functions and a variety of Interface.

$ 3378.00

Adopt bar and Drawdown blade double coating method, coating speed 1~ 300mm/s stepless speed regulation, bar accuracy +/- 0.001mm, equipped with clamshell Drawdown blade head for easy cleaning, Glass countertop heat resistance 600 ℃.

$ 5560.00

Adopt 0.75mm tungsten carbide test head, provide 0-20N three-gear adjustable pressure, accurately detect coating Hardness by scratch method, suitable for different curved surfaces and durable structure.

$ 977.00

The homogenizing time is up to 3000 seconds, the speed range is 100-10000rpm, and the acceleration is 100-10000rpm/s. It supports multi-stage program control. Vacuum chuck ensures the stability of the substrate and is suitable for assembly line processes.

$ 1493.00

Measurement range 0-10mm, accuracy ≤ 0.02mm, equipped with a variety of probe diaMeters including Φ 2mm, Φ 5mm, etc., support different pressure settings, simple and reliable structure.

$ 315.00

High homogenizing efficiency, support 1-5 stage program control, 3000 seconds per period, speed range 100-10000rpm, acceleration 100-10000rpm/s, solenoid valve control gas path suitable for assembly line process.

$ 1461.00

Adopt double grinding head linear friction mode, load 570 +/- 20g adjustable, working plate Rotation speed 0~ 135rpm, magnetic chuck design makes sample loading and unloading convenient, the counter directly reads the number of sanding.

$ 696.00

Articles

The main difference between the high-low temperature test chamber and the constant temperature and humidity test chamber
This article mainly distinguishes between high-low temperature test chambers and constant temperature and humidity test chambers.
Taber Abrasion Test Method for Wear Resistance of Coating Films
This article introduces the Taber abrasion test method, which is used to evaluate the ability of coatings, such as those on floors, furniture, or car interiors, to resist mechanical wear.
Detection Methods and Standards for Ozone Aging Tests on Thin Films
This article primarily introduces the aging test method for thin-film materials in an ozone environment.
How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
The effect of the substrate fixing method on coating uniformity in a vacuum adsorption blade coating tester.
This article discusses the impact of different substrate fixing methods on coating uniformity in a vacuum-assisted knife-over-roll coating tester. It compares four methods—vacuum adsorption, electrostatic adsorption, mechanical clamping, and adhesive fixing—focusing on their mechanical principles and limitations.
Comparison of Coating Accuracy between Laboratory Blade Coater and Slot Die Coater
This article compares the coating precision of blade coaters and slot-die coaters in the laboratory. Blade coaters are suitable for thick coatings, with simple operation but relatively large uniformity errors; slot-die coaters offer higher precision and better uniformity for thin coatings. The choice of equipment depends on coating thickness and precision requirements.
Process optimization of heating coater in lithium battery electrode preparation
This article introduces process optimization methods for heating coaters in the preparation of lithium battery electrodes.
The Stripe Issue Caused by Tension Fluctuations in Roll-to-Roll Laboratory Coaters and Its Solutions
This paper analyzes the causes of and countermeasures for coating streaks resulting from tension fluctuations in roll-to-roll laboratory coaters.
Analysis of Common Defects in Laboratory Coating Machine Blade Coating and Adjustment Methods for Process Parameters
This article introduces common defects in the blade coating process of laboratory coaters, such as streaks, orange peel, bubbles, uneven thickness, and missed coating. It analyzes the causes of these issues, which are primarily related to material properties, operating parameters, and environmental factors.
Different Requirements for Single-Column Testing Machine Selection in Peel Test and Tear Test
This article primarily discusses the different requirements of peel testing and tear testing for selecting a single-column testing machine. Peel testing targets the adhesive surface, involves smaller force values, and requires high-speed loading and specialized fixtures. Tear testing focuses on crack propagation within the material, involves larger force values, and has higher requirements for speed stability.
Comparison of Selection Between Dual-Column Gantry and Single-Column Universal Testing Machines for Plastic and Rubber Testing
This article compares the differences between dual-column portal and single-column universal testing machines in plastic and rubber testing. Dual-column portal types offer high rigidity and large load capacity, making them suitable for high-strength materials and high-precision testing; single-column types have an open structure and low cost, making them ideal for small loads and frequent fixture changes.
How to choose a single-column electronic universal testing machine based on the maximum test force
This article introduces how to select a single-column electronic universal testing machine based on the maximum test force. First, determine the strength range according to the material type and standard, such as plastics, metals, etc. Then, calculate the maximum force based on the tensile strength and specimen area, and multiply it by a safety factor of 1.3 to 1.5.
Flexibility of Elastic Coatings Tested by Cylindrical Mandrel Bend Tester
This article introduces a method for testing the flexibility of elastic coatings using a cylindrical mandrel bending tester. During the test, the coated test panel is bent around cylindrical mandrels of varying diameters to 180 degrees to observe whether the coating cracks or peels off.
Application of Linear Abrasion Tester in Testing Scratch Resistance of Printing Ink Coatings on Packaging
This article introduces the principle, method, and application of the linear abrasion tester in testing the scratch resistance of packaging printing ink coatings.
Application of Drop Hammer Impact Testing Machine in Evaluating Impact Resistance of Composite Materials
This article introduces how the drop-weight impact testing machine evaluates the impact resistance of composite materials. The test releases a weight to strike the specimen, measuring parameters such as energy absorption, peak load, and damage area, simulating low-velocity impacts like tool drops.