Using corrosion-resistant PVC material and titanium alloy heating tube, Temperature Uniformity ≤ +/- 2 ℃, equipped with sulfur dioxide flowMeter and alkali waste gas treatment system to ensure test accuracy and environment safety.
Using PTFE pump head material and coating diaphragm, suitable for strong corrosive gases, pumping speed 20L/min, Ultimate vacuum degree 3~ 8mbar, with pressure relief and cleaning functions, good air tightness and noise less than 58dB.
Using Zirconia Pottery and porcelain material, with High Hardness and Abrasion Resistance, Good Chemical Stability, Suitable for high temperature environment, Range 0~ 25μm, Groove size 140 × 12.5mm, Ensure measurement accuracy and Repeatability.
Pottery and porcelain with Zirconia, High Hardness and Abrasion Resistance, Good Chemical Stability, Range 0~ 25μm, Graduation 1.25μm, Suitable for high temperature and corrosive environment.
With inert gas protection system to prevent oxidation and decarburization of heating workpiece, rated temperature 1200 ℃, Inner Chamber dimensions 300 * 200 * 120mm, suitable for a variety of high temperature heat treatment applications.
Using Zirconia Pottery and porcelain material, with High Hardness and Abrasion Resistance, Good Chemical Stability, Range 0~ 50μm, Graduation 2.5μm, suitable for high temperature and corrosive environment.
With inert gas protection function, it can prevent high temperature heating workpiece oxidation decarburization, rated temperature 1000 ℃, Inner Chamber dimensions 200 * 120 * 80mm, shell made of cold plate and steel and high temperature spray.
The equipment is equipped with an inlet and outlet device, which can pass inert gas to achieve anti-oxidation decarburization at a high temperature of 1000 ° C. Inner Chamber dimensions are 400 * 250 * 160mm, suitable for high temperature sintering and quenching and other heat treatment applications.
Adopting a specific process equipped with air inlet and outlet device, inert gas can be intRoduced to achieve high temperature heating and oxidation prevention, Inner Chamber dimensions 500 * 300 * 200mm, rated temperature up to 1000 ℃, the shell is made of cold plate and section steel and sprayed at high temperature.
Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.
It can detect halogen gas leaks of less than 0.5 ounces per year, with an instantaneous Response Time and a Warm-Up Time of less than 90 seconds. It features automatic warm-up and battery protection, and a portable design weighing only 480 grams.
250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.
Using PTFE pump head and diaphragm material, resistant to strong corrosive gases. Pumping speed 60L/min, Ultimate vacuum degree 3-8mbar, with pressure relief and cleaning functions, good air tightness, operating noise less than 58dB.
Detect NH3 gas, range 0~ 100ppm, resolution 0.1ppm, Response Time T90 ≤ 120s, support sound and light alarm, Operating temperature -10~ 50 ℃, Working time for more than 60 hours, Portable design weighs only 170 grams.
Maximum 4 kinds of gas simultaneous detection, integrated temperature and Humidity compensation, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Protection Rating IP66, suitable for a variety of Installation methods.