Fluid Emulsifier

The fluid emulsifier uses the shear force generated by the high-speed rotation of the rotor and stator to mix immiscible liquids into a uniform emulsion. It is used for pigment dispersion and emulsion preparation in industries such as coatings and inks, achieving material homogenization and stability.
Selection
When selecting, consider the viscosity of the material to match the rotor speed, determine the equipment specifications based on the processing capacity, choose stainless steel or special materials according to corrosion resistance requirements, and decide on continuous or batch operation based on the production process requirements.

Terms

Standards

Instruments

The calibrated value is 470mV, the capacity is 500mL, and the tamper-proof sealing design is adopted to ensure that the standard liquid has a valid period of up to 5 years in the unopened state to ensure the accuracy of calibrating.

$ 164.00

Four-blade structure design, blade width 70mm, Rod length 300mm, low-speed operation to pRoduce tangential flow, the edge of the formation of high shear rate, effectively prevent media deposition, suitable for high viscosity fluid mixing.

$ 99.00

The minimum detection limit of the adapter is 1cP, the operation temperature range is -40 ° C to 250 ° C, the stainless steel material is easy to clean, and the sample dosage is only 18-20mL, which is suitable for low viscosity fluid analysis.

$ 356.00

Using 304 wear-resistant stainless steel material, application width 300mm, wet film thickness 18.3μm, suitable for uniform Spreader experiment of various fluid samples.

$ 167.00

Using 304 wear-resistant stainless steel material, wet film thickness 18.3μm, Spreader width 300mm, suitable for a variety of fluid samples of experimental film requirements.

$ 186.00

Measurement range covers 400~ 1800cst, round head Cup structure ensures fast inspection of various fluid viscosity, correction coefficient 0.95~ 1.05 to ensure data accuracy.

$ 135.00

Using Dial display and manual Rotation speed control, Measurement accuracy of +/- 5%, viscosity range of 10 to 2000000mPa · s, support for a variety of rotor specifications and Rotation speed switching, suitable for a variety of fluid Tack test.

$ 643.00

The gap wire-wound design, wet film thickness of 228.6 μ m, can reduce high viscosity fluid blockage and eliminate scratches, wide and shallow cavity to promote coating flow and wetting.

$ 178.00

Set dispersion and stirring functions in one, Speed range 100-8000rpm, manual lift Travel 250mm, suitable for fluid material experiments, high efficiency and easy cleaning.

$ 369.00

The gap wide-wound design, wet film thickness 354.3 μ m, can reduce fluid blockage and scratches, wide and shallow cavity to promote thick coating flow, improve wetting effect.

$ 178.00

Wire-wound process is prepared with 6.9 μm wet-film, and the diaMeter of the steel wire is only 0.08mm. If the hair is thin, seamless winding reduces the risk of broken wire, and is suitable for a variety of fluid Spreader applications.

$ 186.00

The gap wire-wound structure is adopted, and the wet film thickness reaches 331.5 μm. The thick coating flows more smoothly through the wide and shallow cavity design, which effectively reduces the fluid interruption phenomenon.

$ 178.00

The shear rate is 2.0N, the sample volume is only 400 μL, the applicable viscosity range is 125~ 250000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid tests.

$ 683.00

Using gap wire-wound process, wet film thickness of 377.2 μ m, wide and shallow cavity design to promote high viscosity fluid flow, reduce interruption to achieve complete wetting, application width 300mm.

$ 178.00

The gap wire-wound structure is used to reduce clogging and scratches, the wide and shallow cavity design improves the thick coating flowability, and the 320 μm wet film thickness supports the uniform Spreader of high viscosity fluid.

$ 178.00

Articles

Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Rotational Viscometer for Measuring and Controlling the Application Viscosity of Coatings
A rotational viscometer is a commonly used tool for controlling the viscosity of coatings during application, as it measures the torque generated by a rotor rotating in a fluid to calculate viscosity.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.
The difference between a wire bar coater and a gap-type wet film applicator.
The wire-wound drawdown bar directly quantifies the coating through the gap between wires, making it suitable for thin coating preparation with high precision, particularly for low-viscosity fluids. In contrast, the gap-type wet film applicator indirectly controls film thickness through the groove depth, with the actual coating thickness significantly influenced by material properties, making it more suitable for high-viscosity coatings and thick film preparation.
Types and Selection of Paint Viscosity Cups
As a simple tool for measuring the liquid outflow time, the viscosity cup is mainly categorized into various types such as the Tu-4 cup, ISO cup, Ford cup, and Zahn cup, based on standards from different countries and regions. These cups differ in orifice size, capacity, and the types of fluids they are suitable for.