Tube and Bar Eddy Current Flaw Detector

The tube and bar eddy current flaw detector operates based on the principle of electromagnetic induction. It induces eddy currents on the surface of metal tubes and bars through coils and detects changes in the electromagnetic field caused by material defects. It is used to identify surface and near-surface defects such as cracks and corrosion, making it suitable for both online and offline quality inspection of metal tubes and bars.
Selection
When selecting, consider the type and size of the material to be tested, and match the probe frequency and sensitivity. Choose portable or fixed equipment based on the testing environment. Check the instrument's detection depth and accuracy indicators. Confirm compliance with industry testing standards. Evaluate the operational complexity and maintenance costs of the equipment.

Terms

Instruments

Frequency range 50Hz~ 12MHz, gain 0~ 90dB continuously adjustable, with relatively independent test channels and a variety of Display modes.

$ 8949.00

With a wide frequency range of 64Hz-2MHz, it can detect longitudinal crazing and transverse defects, adapts to a variety of Probe types, supports automatic phase analysis and zero correction functions, and is suitable for high-speed inspection environments.

$ 7335.00

Using 64Hz-2MHz broadband range, it can detect vertical crazing and horizontal defects, with automatic zero correction system and sound and light alarm function, and supports a variety of Probe adaptations.

$ 10401.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 1250μm, error +/- 3%, support Bluetooth transmission and automatic identification of matrix material, suitable for one-handed operation.

$ 564.00

Measurement range of 0-1250 μm using eddy Current principle, single continuous dual mode and large Probe design, support Automatic calibration matrix recognition, error of only +/- 3% resolution up to 0.1 μm.

$ 320.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 2000µm, error +/- 1~ 3%, with automatic identification of matrix material and memory Adjustment, support split Probe to enhance mobility.

$ 338.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 1250μm, error +/- 3%, support single and continuous Measurement mode, automatic identification of matrix material and memory calibrated value, easy to operate.

$ 401.00

Using eddy Current Measurement principle, Measurement range 0~ 1250μm, with continuous single double Measurement mode, metal shell anti-interference, support automatic statistics and storage of 1560 measured values.

$ 344.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 500μm, resolution of 0.1μm, wear-resistant hard metal probe and Automatic calibration function, support USB data communication.

$ 275.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 500um, resolution 0.1μm, wear-resistant hard metal probe and Automatic calibration function, support single and continuous Measurement mode.

$ 275.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 1250μm, resolution of 0.1μm, equipped with wear-resistant hard metal probe, support 99 sets of Data storage and statistical calculation functions.

$ 525.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-2000μm, resolution up to 0.1μm, with automatic identification of substrate function and Data storage ability, support surface measurement minimum convex 1.5mm.

$ 419.00

Using magnetic Induction and eddy Current dual thickness measurement method, Measurement range 0-1500 μm, resolution 0.1 μm, support continuous and single measurement, with statistical function and 500 sets of data storage.

$ 264.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-1250μm, support continuous single two Measurement mode, with automatic statistics and storage function, metal shell anti-interference.

$ 425.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 500μm, resolution 10μm, wear-resistant hard metal probe and Automatic calibration memory function, support USB data communication and automatic shutdown.

$ 240.00