Cable grease viscosity Tester

The cable paste viscometer determines viscosity by measuring the resistance encountered when a rotating spindle or piston moves through the cable paste sample. It is used to control viscosity in the cable paste coating process during cable manufacturing, ensuring uniform filling and insulation performance.
Selection
When selecting, consider that the measurement range covers the actual viscosity of the cable paste, the sample volume adapts to the production line sampling specifications, the temperature control function matches the process environment, the cleaning design reduces residual errors, and the data interface meets recording requirements.

Terms

Standards

Instruments

Contains RS232 data cable and software CD-ROM, which can be connected to a PC for data management operations. It is suitable for all Coating thickness Gauges except CM8829 series.

$ 128.00

Equipped with RS-232 software system, the Probe cable is 1 Meter long and supports the connection between the measuring instrument and the computer, which is convenient for data transmission and processing.

$ 112.00

1KW standard blowtorch, flame height 170-190mm, support 0.1-999 seconds holding time setting, with automatic timing and high voltage ignition function, suitable for flame retardant performance testing of various cable materials.

$ 1219.00

Can simultaneously measure 2 samples, temperature control accuracy 0.1 ℃, using platinum temperature sensor and refrigeration system, support the experimental process recording playback, in line with national standards and ISO standards.

$ 7819.00

Adopting digital signal modulation technology, the output signal is 125 kHz, and the LCD display screen is equipped to display the signal change in real time, which can detect the location and fault of buried cables, and the tracking depth can reach 2.5 Meters.

$ 219.00

High subdivision drive stepper motor ensures accurate and stable Rotation speed, Measurement accuracy of +/- 1% F. S, viscosity range of 1~ 1000000mPa · s, LCD display viscosity, Rotation speed and other Multi-ParaMeter, timing function to ensure thixotropic liquid data conformity.

$ 777.00

Viscosity range 0.6~ 6000000mPa · s, repRoducibility +/- 0.5% F. S, supports continuously variable speed and liquid crystal display of various paraMeters, suitable for ultra-low viscosity sample measurement.

$ 1255.00

2 samples can be measured at the same time, using platinum temperature sensor temperature control accuracy 0.1 ℃, heating rate 0.1-10 ℃/min, automatic recording of the experimental process and support playback.

$ 9885.00

It can extend the measurement length, suitable for long-distance measurement in narrow areas, and supports a variety of curved surface Measurement ranges, including outer cylindrical surface R10-R50, inner cylindrical surface R11-R30 and other specifications.

$ 131.00

Using ARM technology built-in Linux system, viscosity measurement range 1~ 6000000mPa · s, accuracy +/- 1% F.S. Support automatic scanning recommended Rotor speed combination, real-time display of viscosity Linear dispersion and various paraMeters, can save 30 sets of data.

$ 1589.00

Using professional mechanical design and microcontroller control technology, Measurement accuracy of +/- 2% F. S, viscosity range of 1~ 100000mPa · s, with a key to select the rotor number, adjust Rotation speed and read viscosity value convenient operation.

$ 427.00

Microcomputer drive technology and imported stepper motor to ensure smooth speed, measurement accuracy of +/- 1% F. S, repRoducibility +/- 0.5% F. S, with automatic scanning function to help choose the right Rotor speed, with ultra-low viscosity adapter to support viscosity measurement as low as 1cP.

$ 659.00

The diaMeter of the scraping needle is 0.45mm, the scraping speed is adjustable from 10 to 60 times/minute, and it has an automatic shutdown function to ensure accurate and efficient testing. It is suitable for the durability evaluation of insulating materials.

$ 1174.00

Measurement accuracy of +/- 2% F. S, viscosity range of 1~ 2000000mPa · s, with automatic scanning function and automatic stop measurement, support multi-rotor specifications and eight Rotation speed switching.

$ 559.00

Using professional mechanical design and microcontroller control technology, Measurement accuracy of +/- 2% F. S, viscosity range of 1~ 2000000mPa · s, support one-button selection of rotor and adjustment Rotation speed, automatic stop measurement.

$ 465.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.