Digital Emulsifying Machine

The digital display emulsifier generates shear force through high-speed rotation of the stator and rotor, breaking materials into fine particles and achieving uniform mixing. It is used in industries such as coatings and inks to achieve liquid-liquid or liquid-solid emulsification, with a digital screen displaying speed parameters for convenient operation and monitoring.
Selection
When selecting, consider the viscosity of the material to match the motor power, choose the working head size based on the processing capacity, use stainless steel material to accommodate corrosive media, employ variable frequency speed regulation to meet different process needs, and ensure operational stability with safety protection devices.

Terms

Standards

Instruments

Brushless motor to avoid Toner contamination of samples and reduce noise. The processing capacity covers 150 ml to 6 liters, supports a variety of head Modular replacements, and the intelligent Touchscreen can set the program, timing, line speed and torque.

$ 3139.00

Using microcomputer intelligent PID digital display temperature control, temperature control accuracy +/- 1 ℃, equipped with hot air circulation system to ensure uniform temperature, indoor shelf height and quantity adjustable, easy access to different specifications of samples.

$ 288.00

Quadruple Synchronous Stir Design, Temperature range RT +~ 100 ℃, using digital electronic temperature control technology, heating power 150W * 2, stirring speed 0~ 2000rpm, DC motor running without noise vibration.

$ 243.00

Using digital temperature control technology, Temperature range RT +~ 100 ℃, Tank size 300 * 300mm, combined design operation is more convenient, suitable for long-term stable operation.

$ 277.00

Adopting 25 * 25mm square design, the center digital display window shows white characters on a black background after overheating, the frame has regression directional reflection technology, can be identified from a distance in low light environment, waterproof and stain-resistant and with anti-fouling protective film.

$ 89.00

Six-station synchronous operation, Max. stirring Capacity 1000mL × 6, Speed range 50~ 1700rpm, LED digital tube real-time display Rotation speed paraMeters, support Continuous Operating Mode.

$ 517.00

Using refraction principle design, LCD large-screen liquid crystal digital display, quick display results within 3 seconds, automatic temperature compensation function, more than 10,000 times of use, with automatic shutdown and power alarm function.

$ 251.00

Equipped with a digital ruler to collect displacement data, the resolution is up to 0.01mm, the maximum measurement load is 500N, the base has a mobile platform for easy installation of fixtures, and the side handwheel is easy to load and operate.

$ 357.00

Temperature range RT + 5~ 100 ℃, temperature resolution 1 ℃, stainless steel liner corrosion resistance, digital display temperature control is accurate and reliable, suitable for thermostatic auxiliary heating.

$ 259.00

Temperature range RT + 5~ 100 ℃, temperature resolution 1 ℃, stainless steel liner corrosion resistance, digital tube display to ensure accurate and reliable temperature control.

$ 238.00

Using digital temperature control, the reading is intuitive and accurate, Temperature range RT +~ 100 ℃, Tank size 300 * 300mm, integrated design and easy operation.

$ 372.00

DC brushless motor drive, torque up to 80mN · M, temperature control accuracy +/- 1 ℃, support table and liquid temperature dual control, electronic timing up to 9999 minutes, with dual digital display and intelligent PID temperature control function.

$ 412.00

Temperature range RT + 5~ 100 ℃, temperature resolution 1 ℃, stainless steel liner corrosion resistance, digital display temperature control is accurate and reliable, Tank volume 15L.

$ 212.00

With temperature and rotational speed dual digital display function, temperature control accuracy of +/- 1 ℃, using PID self-tuning and thyristor control, Max. stirring Capacity 2000mL, heating power 500W, Pottery and porcelain coated panels are resistant to corrosion and high temperature.

$ 667.00

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, equipped with stainless steel liner and intelligent digital temperature control instrument to ensure temperature Stability and durability.

$ 393.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Shore Durometer Selection: Matching Principles of Hardness Models and Measurement Ranges
This article introduces the selection method for Shore durometers, with the core focus on ensuring that the hardness type matches the material's hardness range and rebound characteristics. When selecting, the principle that the measured value falls within 20% to 80% of the full scale should be followed to avoid data distortion.
Turbidity meter selection: Basis for choosing light source type and measurement accuracy.
This article mainly introduces how to select a turbidity meter based on its light source type and measurement accuracy.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Roughness Measurement Instrument Selection: Contact vs. Non-Contact
This article introduces the differences between contact and non-contact methods when selecting a roughness measuring instrument.
Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.