Digital High-Temperature Emulsifier

The digital display high-temperature emulsifier drives the rotor through a motor to perform high-speed shearing of materials, combined with a heating system to control the temperature, achieving liquid-liquid or liquid-solid mixing and emulsification. It is used in industries such as coatings and inks to uniformly disperse raw materials at high temperatures and enhance product stability.
Selection
When selecting, consider matching the material's viscosity with the speed range, ensuring the heating temperature covers the process requirements, the material's corrosion resistance suits the production environment, inspect the sealing structure to ensure reliable high-temperature sealing, and verify that the digital display accuracy meets control requirements.

Terms

Standards

Instruments

The digital display temperature control is accurate and reliable, the hot air circulation system is composed of a high temperature fan and a suitable air duct to improve the Temperature uniformity in the working room, and the heating wire is installed at the bottom to heat up quickly.

$ 2171.00

Temperature range RT + 5~ 100 ℃, temperature resolution 1 ℃, stainless steel liner corrosion resistance, High Accuracy Sensor and integrated components to ensure accurate temperature control, digital tube display clear and intuitive.

$ 180.00

Using digital temperature control, the reading is intuitive and accurate, Temperature range RT +~ 100 ℃, Tank size 300 * 300mm, integrated design and easy operation.

$ 372.00

Adopting high-temperature non-alkali fiberglass insulation layer sealing resistance wire, the heating area is large and the temperature rises quickly, the maximum operating temperature is 380 ° C and supports continuous work, and the hemispherical design is not easy to bruise Glass ware.

$ 222.00

Inlet and outlet devices are used to intRoduce inert gas to effectively prevent oxidation and decarburization of high-temperature heating workpieces. The Furnace volume is 16L and the maximum temperature is 1200 ° C. The high-temperature spraying process of the shell is durable.

$ 954.00

With 0.0001 ℃ high digital resolution, Temperature Uniformity +/- 0.005 ℃, the use of heat-free centrifugal circulation pump to avoid their own heat impact temperature field, to ensure uniform and stable flow field.

$ 1184.00

Can work at room temperature to 300 ℃ range, using high temperature centrifugal jet circulation pump, head up to 5 Meters, equipped with PID automatic temperature control, digital resolution 0.01 ℃, Temperature Fluctuation +/- 0.05 ℃, domestic circulation system to achieve a high degree of uniform temperature field.

$ 914.00

With temperature and rotational speed dual digital display function, temperature control accuracy of +/- 1 ℃, using PID self-tuning and thyristor control, Max. stirring Capacity 2000mL, heating power 500W, Pottery and porcelain coated panels are resistant to corrosion and high temperature.

$ 667.00

Temperature range RT + 5~ 100 ℃, temperature resolution 1 ℃, stainless steel liner corrosion resistance, digital display temperature control is accurate and reliable, suitable for thermostatic auxiliary heating.

$ 259.00

Temperature range RT + 5~ 100 ℃, temperature resolution 1 ℃, stainless steel liner corrosion resistance, digital display temperature control is accurate and reliable, Tank volume 15L.

$ 212.00

Using Nidec compressor and DuPont environmental protection refrigerant, Humidity control accuracy of 0.1 ℃, equipped with double-decked vacuum heating defrosting observation window and stainless steel sample holder, support multi-stage programming and Data storage.

$ 3301.00

Temperature range RT + 5~ 100 ℃, temperature resolution 1 ℃, stainless steel liner corrosion resistance, digital tube display to ensure accurate and reliable temperature control.

$ 238.00

Temperature range RT + 5~ 100 ℃, temperature resolution 1 ℃, stainless steel liner corrosion resistance, digital tube display to ensure accurate and reliable temperature control, Tank size 150 * 600 * 300mm.

$ 285.00

Rotation speed is accurate and stable with high subdivision stepper motor, viscosity range of 10~ 1000000mPa · s, temperature accuracy +/- 0.1 ℃, support continuously variable speed and direct liquid crystal display, no need for secondary calculation.

$ 1886.00

Using microcomputer intelligent PID digital display temperature control, temperature control accuracy +/- 1 ℃, equipped with hot air circulation system to ensure uniform temperature, indoor shelf height and quantity adjustable, easy access to different specifications of samples.

$ 288.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Melt flow index tester measures the processing fluidity of high-temperature engineering plastics.
This article introduces how a melt flow indexer measures the processing fluidity of high-temperature engineering plastics. It first explains the working principle of the instrument, which involves measuring the rate at which molten plastic passes through a standard die under specific temperature and pressure conditions to obtain the melt flow rate value.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.
Humidity and Heat Test Chamber for Evaluating Coating Performance under High Temperature and High Humidity Conditions
This article introduces how a humidity and heat test chamber is used to evaluate the performance of coatings in high-temperature and high-humidity environments. Coatings are widely used in industries such as automotive and electronics, but they are prone to issues like reduced adhesion and blistering under actual high-temperature and high-humidity conditions.