Micron Film Applicator

The micrometer film applicator controls the coating thickness through precisely machined grooves or gaps, evenly spreading liquid samples onto a substrate. It is used in laboratories to prepare wet films of standard thickness, facilitating subsequent drying, curing, and performance testing. It is suitable for quality assessments such as ink hiding power and coating leveling.
Selection
Select the blade type based on the viscosity of the sample to be tested, using a gap-type blade for high viscosity. Match the substrate width to determine the size of the applicator. Choose the groove depth according to the testing standards, with common depths ranging from 25 to 500 μm. Consider the material's wear resistance: stainless steel is suitable for regular samples, while hard alloys are used for coatings containing abrasives.

Terms

Instruments

Formed to achieve 52.6 micron precision film, 304 stainless steel material provides high Abrasion Resistance, 50mm at both ends of the hand part without additional handle, can be directly matched with the experimental Film Applicator.

$ 167.00

Provides 13.7 micron wet film thickness, optional wide-wound and molded design, 12.7mm diaMeter, 300mm application width, stainless steel material, durable and easy to operate.

$ 186.00

The extrusion process ensures accurate 16 micron wet film thickness, the stainless steel is durable and provides 300 mm application width for efficient sample preparation.

$ 160.00

Spreader 64.0 micron wet film thickness, formed pRoduction process and stainless steel material, total length 400mm application width 300mm, durable and Spreader uniform.

$ 160.00

Wire-wound design can be prepared 160 micron wet film thickness, corrosion resistant stainless steel material, suitable for high viscosity test and not easy to block, longer service life.

$ 160.00

Can be prepative 9.1 micron wet-film, application width 300mm, using formed pRoduction process, suitable for ultra-thin Spreader process, high accuracy.

$ 160.00

Made of 303 stainless steel, wet film thickness 102.9 microns, application width 300mm, suitable for high abrasion and high viscosity experiments, uniform film operation is simple.

$ 167.00

Using stainless steel material, application width 300mm, wet film thickness 77.7μm, film accuracy of 0.1 micron to ensure uniform film.

$ 160.00

303 stainless steel material wear and corrosion resistance, winding 0.89mm steel wire preparatory 80 micron film, application width 300mm and both ends with 50mm hand grip part, easy and stable operation.

$ 167.00

The formed pRoduction process ensures uniform film, provides 47 micron accurate wet film thickness, 304 stainless steel material is durable and easy to clean, suitable for a variety of Coating sample prepative.

$ 120.00

Using a formed pRoduction process, the film Film thickness is as thin as 4.6μm, the accuracy is up to 0.1 micron, and the effective Spreader width is 30cm. It can be used with an automatic Film Applicator and has the advantage of continuous wire.

$ 186.00

Wire-wound technology is a 36.6 micron wet-film with an application width of 300mm, and stainless steel ensures durability for precise Coating thickness control and performance testing.

$ 160.00

Formed to achieve 35 micron wet film thickness, uniform film and good repRoducibility, 304 stainless steel material to ensure durable and easy to clean.

$ 120.00

Wire-wound structure ensures 0.1 micron High Accuracy, wet film thickness 50.3 μm, stainless steel material is durable and easy to clean, and the wide-Rod Film Applicator achieves uniform coating.

$ 160.00

Using a formed process to achieve 330 micron film Film thickness, Spreader width of 25cm, wear-resistant stainless steel material to ensure long-term use Stability, higher accuracy than traditional Film Applicator and easy to clean and maintain.

$ 157.00

Articles

Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Scraper Fineness Gauge for Determining the Fineness of Paste Inks
The Scraper Fineness Gauge is used to measure the dispersion degree of pigment particles in products such as paste inks. Its principle involves scraping a film on a scraper plate with wedge-shaped grooves and observing the scale at which particles appear to assess the fineness, with the result expressed in micrometers.
The role of the coating machine in the preparation of fuel cell membrane electrode assemblies
The film coating machine is a key equipment for preparing the membrane electrode, the core component of fuel cells. It evenly coats a catalyst-containing slurry onto a substrate using techniques such as blade coating, slot-die extrusion, or spraying, forming a catalytic layer ranging from a few micrometers to several tens of micrometers in thickness.
Inventory of Laboratory Coating Instruments
Laboratory coating tools include gap coaters, wire rods, automatic coating machines, etc. What are the differences between them? This article will tell you!
How to Prepare Precise Film Layers Using a Laboratory Film Coating Machine
Precise film preparation can effectively eliminate human operational errors by rationally selecting applicators (wire rods or blades) that match the material's rheological properties and precisely controlling coating speed, environmental temperature and humidity, and substrate conditions.