Sag Determination Tester

The sag tester creates a thickness gradient by vertically scraping a wet film and observes the thickness at which the coating stops flowing to determine its anti-sagging properties. It is used to evaluate the thickness limit for coating application on vertical surfaces before construction, preventing sagging and deformation of the coating.
Selection
When selecting, consider that the scraper's range should cover the sagging thickness of the coating to be tested. Opt for stainless steel material for corrosion resistance, and ensure it includes a level to guarantee vertical alignment during testing. Compare with industry standard specifications to confirm clear, legible scales for easy reading, and ensure compatibility with the dimensions of substrates commonly used in the laboratory.
groove depth

Terms

Standards

Instruments

Film thickness range 650~ 875 μ m, Graduation 25 μ m, stainless steel material, Dimension 120 * 22 * 20mm, suitable for the determination of relative sag of Paints.

$ 154.00

Made of stainless steel, the film thickness range is 250~ 475μm, Graduation 25μm, Dimension 120 * 22 * 20mm, suitable for standard sag performance testing.

$ 154.00

The stainless steel material ensures durability, the film thickness range is 450~ 675 μm, and the groove difference is 25 μm, which is convenient for accurate determination of Coating sag on site.

$ 154.00

A wet film with a film thickness of 50~ 675 μ m was prepared by using a coating scraper, and the sag property was observed when placed vertically. The maximum thickness without sag was expressed, which was suitable for Paints testing.

$ 411.00

Spreader 5 kinds of film thickness, the other side of the test sag cover 10 kinds of thickness 75-300 microns, stainless steel material acid and alkali resistance, in line with ASTM standards, easy to accurately evaluate film performance.

$ 1432.00

The multi-groove coating scraper can scrape 10 wet-films of different thicknesses at one time, the thickness difference of adjacent films is 25um, and the wide film thickness range of 50-675um is supported. It is convenient to visually observe the sag situation by placing the test plate vertically.

$ 315.00

Scratch coating film thickness range of 50~ 275μm, groove difference of 25μm, stainless steel material, compact size of 120 * 22 * 20mm, suitable for the determination of Paints and other pRoducts.

$ 154.00

The device can pRoduce 10 different film thickness stripes, film thickness range 250-475μm, Graduation 25μm, suitable for vertical position testing, to help evaluate coating sag tendency and ensure stable test conditions.

$ 157.00

Dual function design can test leveling and sag at the same time, flow plane supports 5 kinds of film thickness Spreader, flow surface provides 10 kinds of film thickness range 75-300 micron, stainless steel material is acid and alkali resistant, in line with ASTM D4400 and D2801 standards.

$ 1248.00

Using stainless steel material, film thickness range 850~ 1075 microns, groove difference of 25 microns, in line with GB/T9264 standard, suitable for on-site determination of Paints sagging, Dimension 120 * 22 * 20 mm.

$ 154.00

S136 stainless steel material, corrosion resistance and high Hardness; film thickness range 50-275μm, Spreader width 73.5mm, support multi-range optional, clear scale, easy to accurately determine Coating vertical flow performance.

$ 173.00

S136 high grade stainless steel material, corrosion resistance and Hardness, film thickness range of 250~ 475μm, Spreader width of 73.5mm, suitable for a variety of ranges, clear and easy to read scale.

$ 173.00

S136 high grade stainless steel material, corrosion resistance and Hardness, film thickness range 850~ 1075μm, Spreader width 73.5mm, multi-range optional, clear scale, suitable for vertical surface flowability and vertical flow performance evaluation.

$ 173.00

S136 stainless steel material, corrosion resistance and high Hardness, film thickness range of 450~ 675 μ m, Spreader width of 73.5mm, suitable for multi-range testing, clear scale easy to observe sagging phenomenon.

$ 173.00

Determination of wet-film flow thickening in the vertical state, control the physical performance of the coating to select the appropriate wet film thickness, film Film thickness 650-875 μ m, using high-quality wear-resistant corrosion-resistant alloy steel material to ensure durability and accuracy.

$ 146.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Selection Recommendations for Paint Film Cross-Cut Testers Based on Different Adhesion Testing Requirements
This article mainly discusses how to choose the appropriate paint film cross-cut tester based on different adhesion testing requirements.
Evaluation of Coating Adhesion Grade by Cross-Cut Tester Combined with Tape Method