Ion VOC Gas Detector

Ion VOC gas detectors detect the concentration of volatile organic compounds by ionizing gas molecules and measuring changes in ion current. They are used in laboratories and industrial sites to monitor gas leaks of organic solvents, fuels, etc., ensuring environmental safety.
Selection
When selecting, consider that the detection range should cover the target gas concentration, the response time should meet monitoring requirements, the sensor lifespan and calibration cycle should align with usage frequency, the instrument's protection rating should be suitable for the on-site environment, and the data output interface should be compatible with the recording system.

Terms

Standards

Instruments

Adopt PID light ion detection principle, range 0-50ppm, Response Time ≤ 30S, with explosion-proof structure, multiple signal output and remote alarm function, support customized wireless transmission.

$ 1171.00

Pump-suction sampling and imported Electrochemical sensor, Response Time ≤ 20 seconds, resolution 0.01ppm, support 1-5 Sensor expansion, IP65 Protection Rating, suitable for harsh environments.

$ 754.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, with explosion-proof structure and a variety of signal output interfaces, support remote monitoring and linkage control.

$ 332.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds; with flameproof structure and a variety of signal output, support remote monitoring and customized range, through a number of international safety certifications.

$ 332.00

Pump-suction sampling and a variety of detection principles, Response Time ≤ 20 seconds, accuracy ≤ +/- 3%, built-in 3800mAh battery, support 120,000 sets of Data storage and Temperature Humidity detection.

$ 527.00

Using 32-bit microprocessor and 24-bit ADC chip, equipped with 2.4-inch high definition display, supports 1-6 Sensor configurations, with 4-20mA, RS485 and other signal output, Protection Rating up to IP65, Response Time ≤ 20 seconds.

$ 545.00

Pump-suction sampling and PID Photoion Sensor technology, Response Time ≤ 20 seconds, resolution of 0.001 ppm, IP65 Protection Rating and explosion-proof certification, support for multi-Sensor expansion and Data storage functions.

$ 2557.00

250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.

$ 127.00

Adopt PID photoion detection principle, range 0-50ppm, Response Time ≤ 30S, support 4-20mA, RS485 and wireless signal output, with explosion-proof structure and remote monitoring capability.

$ 1171.00

Equipped with 2.4-inch high definition color screen, supports 1-6 Sensor expansion, with 4-20mA and RS485 output, Response Time ≤ 20 seconds, Protection Rating IP65, suitable for harsh industrial environments.

$ 583.00

ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, copper ion type, capacity 480 ml, to ensure ElectRode performance stability and measurement accuracy.

$ 135.00

ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, providing bromine ion type and 480mL capacity to ensure stable ElectRode performance.

$ 135.00

It can simultaneously detect 7 paraMeters such as PM2.5, formaldehyde, and TVOC, with an accuracy of +/- 10%. It is equipped with a 2.8-inch true color screen to display real-time trend charts, and supports 5000 data records and dual national standard selection.

$ 189.00

Using PID Sensor technology, range 0~ 500ppm, resolution 0.1ppm, support 1-6 Sensor expansion, with a variety of signal output modes, including 4-20mA, RS485 and relay output, Protection Rating IP65, suitable for harsh environments.

$ 1818.00

Adopt ultra-low VOC background concentration control technology, background concentration formaldehyde ≤ 0.006mg/m ³; equipped with independent variable frequency wind speed adjustment device, the wind speed range is 0.1-1 m/s; Modular design is easy to maintain, and the integrated gas supply purification system is easy to operate.

$ 35348.00

Articles

Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Differential pressure method gas permeameter measures oxygen transmission rate of films.
This article introduces the method of measuring the oxygen transmission rate of films using the differential pressure gas permeation apparatus.
Heating and blade coating of gel electrolyte films for zinc-ion batteries.
This article introduces the heating doctor-blade coating method for preparing gel electrolyte films in zinc-ion batteries. The method involves spreading a slurry onto a substrate using a doctor blade, followed by heating to evaporate the solvent and form a film.
Uniform coating of lithium-ion battery cathode slurry on aluminum foil.
This article primarily discusses how to uniformly coat the positive electrode slurry onto aluminum foil in lithium-ion battery manufacturing. The slurry itself exhibits shear-thinning properties, making it suitable for coating applications.
The film coater achieves controllable coating of lithium-ion battery anode slurry on copper foil.
This article explores how coating machines control the application process of the negative electrode slurry onto copper foil in the manufacturing of lithium-ion batteries.
The film coater is used for experimental-grade uniform coating of lithium-ion battery cathode slurry on aluminum foil.
This article explores the technique of uniformly coating lithium-ion battery cathode slurry on aluminum foil using a laboratory-grade coating machine.
Heating coating machine is used for the doctor-blade coating of gel electrolyte films in zinc-ion batteries.
This article introduces the blade coating process for preparing gel electrolyte films for zinc-ion batteries using a heated coating mechanism. By controlling parameters such as temperature, coating speed, and gap height, this method enables the fabrication of films with uniform thickness and smooth surfaces.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
BET surface area analyzer evaluates the pore structure of ion exchange resins
This article introduces how to use a specific surface area analyzer to evaluate the pore structure of ion exchange resins.
Automatic Potentiometric Titration for Rapid Detection of Chloride Ion Content in Cement
This article introduces a method for rapidly detecting the chloride ion content in cement using an automatic potentiometric titrator. Excessive chloride ions can corrode steel reinforcement and affect the lifespan of concrete, making accurate detection crucial.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Total Chlorine Content Microcoulometric Titration Detector for Pulp
This article introduces a method for detecting the total chlorine content in pulp using a microcoulometric titrator. The principle involves generating a titrant through electrolysis, which reacts with chloride ions produced from the combustion of the sample. The chlorine content is accurately calculated by monitoring the amount of electricity consumed.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.