Thin Film Heater

The film-scraping heater uses electric heating elements to heat the metal scraper, forming a uniform thermal film on the substrate surface. It is used for testing the coating thickness of paints and inks, simulating different drying conditions by controlling the temperature, and assisting in evaluating the film-forming properties of materials.
Selection
When selecting, consider matching the heating temperature range with testing requirements, ensure the scraper material is corrosion-resistant, account for heating rate's impact on testing efficiency, prioritize temperature control accuracy for data reliability, ensure equipment dimensions fit sample specifications, and verify interface compatibility with existing experimental workflows.

Terms

Standards

Instruments

The special forming process heater has no warpage deformation at high temperature, excellent corrosion resistance of the spray panel, uniform working surface temperature, Heating power 2 × 1000KW, rapid and safe heating.

$ 128.00

Using extrusion process and chrome plating surface, the wet film thickness can be as low as 1.5 μ m, and the groove design is wide to improve the Coating Weight, which solves the problem of traditional steel wire loosening and cleaning difficulties, and realizes stable ultra-thin Spreader.

$ 477.00

The wet film thickness can be as low as 1.5μm to achieve ultra-thin Spreader; the bottom of the groove is wider, and the Coating Weight is larger; the extrusion process is adopted to avoid the problem of loose wire and broken wire, and it is easy to clean.

$ 477.00

Travel 0-1.25 mm, measurement error +/- 1HAM, suitable for thin rubber samples with a thickness of 1.5mm or more. Sensitivity is high, and it needs to be used with a constant load measuring rack to ensure Precision.

$ 921.00

Echo-echo technology implementation of 0.15mm ultra-thin part measurement, resolution of 0.001mm, can penetrate 0.5mm coating measurement substrate Film thickness, support sound speed calibrated and difference mode settings.

$ 1655.00

Using a formed pRoduction process, the film Film thickness is as thin as 4.6μm, the accuracy is up to 0.1 micron, and the effective Spreader width is 30cm. It can be used with an automatic Film Applicator and has the advantage of continuous wire.

$ 186.00

Linear dispersion surface is formed by cold extrusion processing technology, no risk of wire loosening, wet film thickness 50 μ m, can achieve ultra-thin film Spreader, smooth surface and easy to clean.

$ 267.00

Wet film thickness can be as low as 1.5μm, support ultra-thin Spreader; use extrusion process and chrome plating surface to reduce clogging and disconnection problems, groove design to optimize Coating Weight, adapt to a variety of substrate needs.

$ 477.00

Using formed pRoduction process, wet film thickness 0 μ m, film accuracy of 1 μ m, special groove structure to ensure uniform Spreader and easy to clean.

$ 120.00

Using oil Bath heating medium, Temperature range from room temperature to 200 ℃, temperature control accuracy +/- 0.5 ℃, equipped with sample clamping grid to ensure temperature stability, suitable for various film thermal cissing rate tests.

$ 1510.00

Spreader formed process ensures uniform, wet film thickness of only 1.5μm, to achieve ultra-thin film; stainless steel material is durable and easy to clean, suitable for precision Spreader applications.

$ 157.00

Linear dispersion formed by cold extrusion processing technology, no risk of wire loosening, Spreader 2 μ m ultra-thin film, smooth surface easy to clean, wet film thickness 100 μ m, diaMeter 16mm to meet the needs of precision Spreader.

$ 477.00

Linear dispersion of the surface is processed by cold extrusion technology, no risk of steel wire loosening and breaking, wet film thickness 80 µm, diaMeter 16mm, easy to clean and ultra-thin film Spreader.

$ 477.00

Made of stainless steel wear-resistant material, wet film thickness 41.1 μ m, application width 300mm, suitable for thin coating scraping test of soft materials, durable.

$ 160.00

The special cold extrusion process is used to make a continuous groove structure, without the risk of broken wire, the film thickness is 0μm, the diaMeter is 10mm, the application width is 250mm, and the force is uniform to reduce the error.

$ 157.00

Articles

Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Quantitative Measurement of Carbon Black Content in Rubber by Thermogravimetric Analyzer
Thermogravimetric analyzers measure changes in sample mass through programmed temperature control, enabling the quantitative determination of carbon black content in rubber. During the experiment, the rubber is first heated in an inert atmosphere to decompose it, leaving the carbon black intact. The atmosphere is then switched to an oxidizing environment to oxidize the carbon black. The carbon black content is calculated based on the mass loss.
Vicat Softening Point Tester measures the heat resistance of plastics.
This article introduces how a Vicat softening point tester measures the heat resistance of plastics. During the test, the instrument applies a fixed load to the plastic sample and heats it at a constant rate. When the flat-ended needle penetrates the sample to a depth of 1 millimeter, the temperature at that moment is recorded, which is known as the Vicat softening point.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.
Heating and blade coating of gel electrolyte films for zinc-ion batteries.
This article introduces the heating doctor-blade coating method for preparing gel electrolyte films in zinc-ion batteries. The method involves spreading a slurry onto a substrate using a doctor blade, followed by heating to evaporate the solvent and form a film.
Heating coating machine is used for the doctor-blade coating of gel electrolyte films in zinc-ion batteries.
This article introduces the blade coating process for preparing gel electrolyte films for zinc-ion batteries using a heated coating mechanism. By controlling parameters such as temperature, coating speed, and gap height, this method enables the fabrication of films with uniform thickness and smooth surfaces.
The heating film coater applies thick-film resistor paste onto the ceramic substrate.
The heating coating machine is used to apply thick film resistor paste on ceramic substrates. It reduces the viscosity of the paste through a heating platform and ensures uniform coating in conjunction with the coating head.
Vicat Softening Point Tester evaluates the heat deformation resistance of resins.
The Vicat softening point tester is used to measure the thermal deformation resistance of resins. It heats and applies pressure to the specimen until it deforms by 1 millimeter, recording the temperature at that point as the softening point.
Muffle furnace is used for the determination of coating loss on ignition and ash content.
A muffle furnace is a laboratory heating device used to determine the loss on ignition and ash content of coating materials. By incinerating the sample at high temperatures, the organic components decompose and volatilize, leaving behind inorganic residues as ash.
Thermogravimetric Analyzer for Determining the Solid Content of Varnish
The principle of determining the solid content of varnish using a thermogravimetric analyzer is as follows: when the sample is heated, volatile solvents and moisture evaporate, leading to a decrease in mass, while the remaining solid mass stabilizes. The solid content is calculated by comparing the initial and final mass ratios.
Effect of Platform Temperature on Surface Drying Time of Waterborne Polyurethane Coatings in Heated Automatic Film Applicators
This study investigates the influence of the platform temperature of a heated automatic film applicator on the surface drying time of waterborne polyurethane coatings. The experiments reveal that as the platform temperature increases, the surface drying time of the coating significantly decreases, showing a negative correlation between the two.
Application of Vacuum Heating Integrated Coating Machine in the Preparation of High-Temperature Curing Coating Samples
This article introduces the application of the vacuum heating integrated film coater in the preparation of samples for high-temperature curing coatings. The equipment reduces bubbles in the coating by creating a vacuum environment and integrates programmable heating and curing functions, enabling precise temperature control to promote the chemical cross-linking of the coating and form a uniform film.