The gloss meter determines gloss by measuring the ratio of reflected luminous flux to refracted luminous flux on the coating surface. It is used to evaluate the reflective properties of coating surfaces and control the appearance quality in industries such as automotive and furniture.
Selection
When selecting, consider matching the measurement angle to the sample's gloss range: use a 20° angle for high-gloss surfaces and an 85° angle for matte surfaces. Ensure the instrument complies with ISO 2813 standards and verify the traceability certificate of the calibration plate. Choose between portable or benchtop models based on the usage scenario.

Terms

Standards

Instruments

With 20 °, 60 °, 75 ° multi-angle measurement function, Measurement range 0~ 2038GU, Repeatability 0.5GU, using photoelectric detection technology, support automatic printing and statistical calculation, suitable for accurate detection of different Glossiness surfaces.

$ 1865.00

With three projection angle measurement function, Measurement range 0~ 2000GU, Repeatability +/- 0.5GU, can simultaneously measure Glossiness and fog shadow value, support 56 groups of Data storage.

$ 992.00

With 20 °/60 °/85 ° three-angle measurement capability, Measurement range 0~ 200GU, support USB and Bluetooth dual data output, built-in rechargeable battery and equipped with backlight display, suitable for accurate detection of different Glossiness materials.

$ 375.00

Adopt 60 ° general angle, range up to 1000GU, Repeatability +/- 0.2GU, resolution 0.1GU, support immediate release and QC mode, automatically determine the qualification and improve the detection efficiency.

$ 264.00

Adopt 60 ° Measurement Angles, Measurement range 0-1999GU, accuracy +/- 1.0GU, with on-site error compensation function and long 48-hour battery life to ensure stable and reliable measurement data.

$ 364.00

With 60 ° Measurement Angles and 0~ 199.9GU Measurement range, Stability up to +/- 0.4GU, rechargeable battery design, compact and easy to carry, suitable for surface Glossiness detection.

$ 299.00

With 20 °, 60 °, 85 ° three angle measurement capability, Measurement range 0-199.9GU, using portable design using No. 5 battery power supply, suitable for field and no power field use, measurement diaMeter is 16x48mm rectangular window.

$ 469.00

60 ° universal angle design, range up to 1000GU, Repeatability 0-100GU is +/- 0.2GU, with Ambient Temperature Compensation and QC mode, support PC software Connectivity measurement and data statistics.

$ 312.00

Coating speed range 0.1~ 500mm/s, stroke length Precision +/- 2mm, equipped with intelligent lighting interface and Vacuum chuck function, support a variety of film tools to achieve uniform and repeability film applications.

$ 15157.00

Imported chip efficiency of 97%, sustainable use for 48 hours, with on-site error compensation function, Indication Error +/- 1.2GU, Stability 0.4GU, stable and reliable measurement data.

$ 307.00

With 60 ° Measurement Angles and 0~ 1200GU wide Measurement range, equipped with a full-color display, a single charge can be continuously measured 15,000 times, Measurement time is less than 1 second.

$ 218.00

Portable photoelectric combination design, Measurement range 0~ 199.9GS, projection angle 20º, 60º, 85ºoptional, Stability less than +/- 0.4GS/30min, suitable for a variety of flat material Glossiness detection.

$ 364.00

With 60 ° Measurement Angles and 0~ 2000GU wide range, Graduation 0.1GU, single charge can be continuous measurement 30000 times, equipped with full color display and Bluetooth interface.

$ 299.00

Adopt 60 degree Measurement Angles, Measurement range 0~ 300GU, equipped with 1.5 * 3mm elliptical measurement port, suitable for complex surface measurement, no need for frequent calibrating, Stability up to +/- 0.4GU, support a variety of standard specifications.

$ 490.00

Imported chip efficiency of 97%, a charge can be used for 48 hours; equipped with on-site error compensation function to ensure accurate data, Measurement range 0~ 199GU, accuracy +/- 2GU, Stability 1GU.

$ 227.00

Articles

Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Technical Details of Measuring Paint Contrast Ratio Using Black-and-White Checkerboard Method with Hiding Power Card
This article introduces a method for measuring the hiding power of coatings using black and white checkerboard paper.
Wear testing machine evaluates the wear resistance performance of wood and floor coatings.
This article introduces how to use a wear testing machine to evaluate the wear resistance of wood and floor coatings.