The drying degree tester simulates conditions of pressure or friction on material surfaces to detect the curing state of coatings. Its principle is based on contact mechanical testing, and its function is to determine the surface drying and through-drying times of coatings. It is applied in production process control for ink printing, plastic coating, and other applications.
Selection
When selecting, consider matching the material type with the testing method, ensure the instrument's range covers the sample drying scope, check the durability of the indenter or friction components, assess the simplicity of the operation interface, and verify compliance with standard specifications such as ASTM D5895.

Terms

Standards

Instruments

90 degree right angle Probe design for low headroom area operation, Measurement range 0-1500 μm, accuracy of +/- 1%, using stainless steel sealing structure to achieve complete waterproof function.

$ 1290.00

60 degree projection angle design, Measurement range 0~ 200GU, Repeatability 0.2GU, Support Automatic calibration and a variety of Measurement mode, built-in large-capacity lithium battery can work continuously for more than 12 hours.

$ 280.00

Suitable for paper or Cardboard dust degree determination, in line with national standards, the effective area of the table is 0.0625 square Meters and can be 360 ° swirl/spin, and the standard dust map area is 0.05~ 5.0mm ².

$ 361.00

90 degree Probe design for narrow space measurement, Measurement range 0~ 1500μm, accuracy +/- 1%, support Data storage and USB transmission, Protection Rating IP65, in line with ISO, ASTM and other international standards.

$ 1180.00

Using 75 degree Measurement Angles, Measurement range 0~ 300GU, Indication Error +/- 1.2GU, equipped with rechargeable battery with long service life, suitable for low Gloss object surface measurement.

$ 457.00

Measurement unit with Baume degree, sugar content accuracy +/- 0.1 ° Baumé, automatic temperature compensation, 1.5 seconds fast display results, only 2 drops of sample, waterproof design for a variety of environments.

$ 567.00

Adopt 60 degree Measurement Angles, Measurement range 0~ 199.9Gs, Indication Error +/- 2GU, equipped with elliptical measurement port and 10 * 20mm Measuring Area, Stability is high and easy to carry.

$ 296.00

Using 60 degree Measurement Angles, Measurement range 0~ 199.9Gs, Indication Error less than 1.2GU. With Automatic calibration and continuous test function, LED long life Illuminant, two AA batteries can measure nearly 10,000 data.

$ 219.00

Using 60 degree stylus end design, radius 50μm, Measurement range 0~ 500μm, accuracy +/- (5μm + 5%), split Probe structure is easy to operate and maintain.

$ 774.00

With full light 10~ 50 ℃ and no light 5~ 50 ℃ Temperature range, Temperature Uniformity +/- 2 ℃, Illumrination degree ≥ 2500lx, suitable for a variety of experimental needs, stable and reliable performance.

$ 975.00

Using 45 degree Measurement Angles, Measurement range 0-300GU, accuracy +/- 1.2GU, equipped with Ni-MH rechargeable battery, compact size, high Stability, suitable for a variety of material surface Gloss detection.

$ 448.00

The use of 20W fluorescent light source, irradiation angle of 60 °, standard dust map area of 0.05~ 5.0mm ², the table can be 360 ° swirl/spin, to meet the needs of accurate paper dust detection.

$ 488.00

24-Stage program can be set to simulate day and night temperature changes, Illumrination degree 0~ 25000LX four-level adjustable, unique air duct to ensure uniform temperature and do not blow seedlings, independent temperature limit alarm system to ensure safe operation.

$ 1942.00

Using 20 degree Measurement Angles, Measurement range 0~ 300GU, Indication Error +/- 1.2GU, equipped with elliptical measurement port and Ni-MH rechargeable battery, suitable for high Gloss object surface detection.

$ 448.00

Dual function design for simultaneous measurement of metal and Coating surface, 60 degree projection angle, Display range 0-1000 Gloss unit, resolution up to 0.1, equipped with large LCD screen and Ni-MH rechargeable battery, Stability +/- 2GU.

$ 351.00

Articles

The Application of Contact Angle Measurement Instruments in the Study of the Relationship Between Ink Printing Wettability and Substrate Surface Tension
This article introduces how a contact angle measuring instrument is used to study the relationship between wettability and substrate surface tension in ink printing. It first explains the principle, assessing the degree of wettability through the size of the contact angle, where an angle less than 90 degrees indicates good wettability.
The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Surface Absorbency Tester for Predicting Drying Speed of Printing Ink on Coated Paper
This article explores how the surface absorbency tester predicts the drying speed of ink on coated paper. Traditional methods rely on actual printing tests, which are time-consuming and difficult to quantify.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Rubber non-rotor vulcanization tester measures vulcanization curve.
The rubber non-rotor vulcanization tester is used to measure the curve of torque versus time during the vulcanization process, in order to assess the crosslinking degree and vulcanization characteristics of rubber.
Haze and transmittance integrated machine measures the quality of functional films.
This article introduces how an integrated haze and transmittance meter measures the quality of functional films. Haze refers to the degree to which a material scatters light, while transmittance reflects its overall ability to transmit light.
Transmittance Tester Measures the Clarity of Optical Films
This article introduces how to use a transmittance tester to measure the clarity of optical films. Clarity refers to the fidelity of imaging after light passes through the film. The tester is based on the principle of light transmission, calculating the clarity value using a formula by measuring the intensity of parallel transmitted light and scattered light.
Friction Coefficient Tester Measures the Slip and Openability of Films
This article introduces how to use a coefficient of friction tester to measure the slipperiness and openability of films. Slipperiness refers to the sliding characteristics of the film surface, while openability indicates the ease of separation between film layers. Both are crucial for processing efficiency in industries such as packaging.
Selection of Temperature and Humidity Meters: Sensor Accuracy and Response Time
When selecting a temperature and humidity meter, sensor accuracy and response time are key parameters. Accuracy refers to how close the measured value is to the actual value, typically expressed as an allowable error, with high-precision sensors being more costly.
How to Match the Selection of Fineness Gauge with Grinding Process Requirements
The fineness gauge is used to measure the particle dispersion of materials such as slurries and coatings, reflecting the particle size distribution through the depth of grooves on its surface.
The coating machine applies the adhesive layer of the plaster patch onto the backing layer.
The coating machine applies adhesive evenly onto the backing material through steps such as feeding, coating, drying, and winding, forming a stable adhesive layer.
The oral dissolving film is uniformly coated by a film applicator and then dried and formed.
Oral dissolving films are prepared by a coating mechanism, where a liquid containing film-forming materials is uniformly applied onto a substrate, followed by drying to remove the solvent and form a solid film.
UV aging test chamber for evaluating the discoloration degree of resin weather resistance
This article introduces the method of using a UV aging test chamber to examine the degree of weather-induced discoloration in resins.