With 60V DC voltage and 25A current output to meet the needs of large area samples; equipped with electrolysis liquid circulation and chill down device to ensure polishing conformity and Stability.
Using pre-pressure technology to ensure stable exudation of electrolysis in viscous samples, equipped with Protelyte oily electrolysis solution to avoid protein reaction, membrane Impedance < 500MΩ, Temperature range 0~ 130 ℃, suitable for high temperature and high voltage environment.
Pre-pressurization technology is used to ensure stable exudation of electrolysis solution in viscous samples, equipped with 3 ceramic core liquid network parts and Protelyte oily electrolysis solution, membrane Impedance < 200MΩ, effectively prevent protein settling blockage, suitable for high temperature and high voltage environment.
Pre-pressurization technology is used to prevent clogging of viscous samples, Protelyte oily electrolysis solution avoids protein reaction, ceramic core liquid network design, Temperature range -5~ 100 ℃, Membrane Impedance < 150MΩ.
Pre-pressurization technology is used to prevent clogging of viscous samples, Protelyte oily electrolysis solution avoids protein reaction, three ceramic core liquid network design, Temperature range 0~ 130 ℃, Membrane Impedance < 200MΩ.
Double-sided uniform tin plating, surface mass I, Hardness T52, standard thickness 0.28mm, provide crimping listening plate, rounded corners with or without holes and other specifications, single batch pRoduction of 10w sheets.
Using double-sided uniform tin plating process, the surface mass reaches class I, Hardness T52, standard thickness 0.28mm, to ensure accurate and reliable film test results.
Using double-sided uniform tin plating process, the surface mass reaches class I, Hardness is T52, standard thickness is 0.28mm, to ensure accurate and reliable film test results.
Using eddy Current thickness measurement principle, Measurement range 0-1000μm, resolution 0.1μm, minimum measurable convex curvature 3mm, with automatic shutdown and low voltage prompt function.
Operating temperature range 0-70 ° C, temperature sensor, multi-pin connector support, maximum pressure 0.2 bar.
Pre-pressurization technology is used to ensure stable exudation of electrolysis in viscous samples, equipped with a three-ceramic core liquid network structure to reduce the risk of clogging, Protelyte oily electrolysis solution avoids reaction with proteins, membrane Impedance is less than 200MΩ, suitable for -5~ 100 ℃ Temperature range.
The use of PTFE oxygen permeable membrane to ensure oxygen permeability, spiral cap design for easy installation and electrolysis filling, suitable for Portable dissolved oxygen measurement equipment maintenance.
Using open liquid complex structure, equipped with solid polymer reference electrolysis solution, the membrane resistance is less than 200MΩ, suitable for -5~ 80 ℃ wide temperature environment, to ensure long-term stable measurement.
The Coulomb Titrimetric method does not require a standard titration solution, the third-gear electrolysis current can be selected from 10mA, 20mA, 40mA, and supports Data storage and USB communication. Measurement range 0.0~ 100.0mg/L can be extended to 1000mg/L.
Open + ceramic core liquid complex design, equipped with solid polymer reference electrolysis solution, membrane Impedance below 250MΩ, Measurement range covering 0~ 14pH, temperature adaptability 0~ 80 ℃, to ensure long-term Stability and Fast Response.