Initial Viscosity Tester

The initial viscosity tester measures the fluid's initial flow resistance through rotation or falling ball methods, used to assess the viscosity of materials such as coatings and inks under low shear rates, guiding production formulation and application performance adjustments.
Selection
Select a model with a matching range based on the viscosity range of the material being tested, consider temperature control requirements, verify the compatibility of the rotor or measurement system with the material, ensure the data output method meets recording needs, and balance operational convenience with maintenance costs.
Tilt angle

Terms

Standards

Instruments

Adopting the test principle of inclined rolling ball method, the tilt angle adjustment range is 0~ 40 °, equipped with 32 GCr15 bearing steel balls, and the shape tolerance accuracy exceeds GB/T308 level 40 to achieve accurate initial Tack evaluation.

$ 296.00

The equipment tests the initial Tack by short contact between steel ball and adhesive tape sample at a small pressure, adjustable tilt angle 0~ 60 °, rolling ball range 1/32 inch to 1 inch, suitable for a variety of material adhesion evaluation.

$ 240.00

Measurement range 0~ 100N, accuracy less than +/- 1%, can store 20 sets of data and print reports, humanized fixture supports a variety of substrates.

$ 3419.00

Adjustable tilt angle 0~ 40 °, the steel ball meets the standard of GB/T308 grade 40 or above, which is convenient for angle and position adjustment.

$ 299.00

Using imported Sensor and motor, Measurement range 0~ 200N, accuracy less than +/- 1%, can store 20 sets of data and automatically print reports, support a variety of substrate replacement.

$ 3419.00

The axial flow fan is used to supply air and support stepless speed regulation of 0~ 3m/s, and the anemoMeter has a range of 0~ 10m/s, which is suitable for the determination of the initial drying anti-cracking performance of laminated architectural coatings.

$ 490.00

Adopting the principle of the inclined rolling ball method, the adhesion is measured by the short contact between the steel ball and the sample, the adjustment range of the tilt angle is 0-60 °, and the rolling ball of 1/32 to 1 inch is supported. The width of the test area is 80mm.

$ 338.00

Sensor and motor imported, Measurement range 0~ 100N, accuracy less than +/- 1%, Test speed 300mm/min, can record the maximum tension and failure mode.

$ 1853.00

Measurement range 0~ 500N, accuracy less than +/- 1%, can store 20 sets of results and print reports, humanized fixture supports a variety of substrates.

$ 3419.00

Sensor and motor imported, Measurement range 0~ 300N, accuracy less than +/- 1%, can store 20 sets of data and automatically calculate the maximum, minimum, average, support a variety of substrate testing.

$ 3419.00

Using imported Sensor and motor, Measurement range 0~ 50N, accuracy less than +/- 1%, can store 20 test results and print reports, humanized fixture supports changing substrate.

$ 3419.00

The device provides 3 +/- 0.3m/s wind speed through axial flow fan in wind tunnel, Timer delay range of 0.01 seconds to 99 hours 99 minutes, can automatically control drying time and eye test plate surface crazing, support parallel test.

$ 364.00

Adopting axial flow fan to supply air, the wind speed can be adjusted steplessly, the wind speed in the wind tunnel is 3 +/- 0.3m/s, and it is equipped with Handheld AnemoMeter measurement, which is suitable for coating drying anti-crack performance testing.

$ 687.00

Using axial flow fan and test wind tunnel structure, the wind speed can be adjusted in the range of 3 +/- 0.3m/s, equipped with Timer delay range of 0.01 seconds to 99 hours and 99 minutes, automatic detection of material surface crazing.

$ 456.00

The device places the test plate in parallel in the wind tunnel, the wind speed control accuracy is 3 +/- 0.3m/s, the drying time is automatically controlled, and the surface crazing can be visually inspected, which is suitable for the evaluation of coating anti-crack performance.

$ 490.00

Articles