Continuous Gas Alarm System

Fixed gas detectors use sensors to measure the concentration of specific gases in the air and trigger audible and visual alarms when the concentration exceeds a preset threshold. They are used in locations such as chemical plants and petroleum facilities to continuously monitor for leaks of combustible or toxic gases, ensuring production safety.
Selection
When selecting, consider the types of gases to be detected, the measurement range, and the explosion-proof rating. Determine the sampling method based on the installation environment, check the sensor lifespan and calibration cycle, and confirm whether the alarm logging function and communication interfaces meet on-site management requirements.

Terms

Standards

Instruments

Support 4-20mA signal input and RS485 upload, with 2-level alarm and 2 relay output, compatible with two-wire and three-wire equipment, fast response speed and high measurement accuracy, suitable for a variety of Gas detection scenarios.

$ 140.00

Support 4-20mA/RS485 signal input, compatible with two-wire and three-wire devices, providing up to 6 passive switching quantities, two-level alarm can be freely set, suitable for gas safety detection.

$ 259.00

Supports 4-20mA signal input, compatible with two-wire and three-wire devices, provides 6 passive switches and RS485 interfaces, with two-level alarm settings, operating temperature 0-40 ℃, suitable for gas safety detection.

$ 212.00

Support 4-20mA signal input, compatible with two-wire and three-wire devices, providing up to 6 passive switching and sound and light alarm functions, operating temperature 0-40 ℃, suitable for a variety of Gas detection scenarios.

$ 183.00

Support 4-20mA/RS485 signal input, provide 6 passive switching and sound and light alarm functions, operating temperature 0~ 40 ℃, compatible with two-wire and three-wire equipment, suitable for gas safety detection.

$ 259.00

Support 16 4-20mA signal input, 4.3 inch color screen display, can store 20000 alarm records, with two-level alarm and four sets of relay output, suitable for multi-point centralized control of Gas detection.

$ 259.00

Support 4-20mA and RS485 signal input, compatible with two-wire and three-wire devices, provide 6 passive switching control ports, with two-level alarm setting and alarm record query function, temperature operation range 0-40 ℃.

$ 183.00

High-precision Sensor is used to detect PM2.5 concentration, Response Time is instantaneous, Sensitivity can be adjusted to 5PPM, with sound and light alarm and automatic warm-up function, continuous work for 5 hours.

$ 157.00

Using Industrial Sensor, Response Time less than 30 seconds, accuracy +/- 3% FS, shell explosion-proof structure, 4-20mA standard signal output, can detect a variety of gas concentrations and have sound and light alarm function.

$ 267.00

Explosion-proof structure design, Response Time is less than 30 seconds, with 4-20mA standard signal output, can detect a variety of gas concentrations and set high and low alarm points to ensure industrial environment safety monitoring.

$ 267.00

Using Semiconductor Sensor, Response Time T90 is less than 10 seconds, detecting a variety of combustible gases, range 0~ 50% LEL, with sound and light alarm and LED large screen display.

$ 141.00

With independent temperature limit alarm system to ensure safe operation, Temperature resolution of 0.1 ℃, hot air circulation system to improve Temperature Uniformity, can adjust the air intake and exhaust from the panel, support optional data recording and communication functions.

$ 699.00

ABS + PC shell is sturdy and durable, equipped with 2.0 inch 320 * 240 resolution display screen, supports methane, O2, H2S, CO four Gas detection, Response Time is the fastest 20 seconds, battery life is 8 hours, with sound and light vibration triple Alarm mode.

$ 344.00

Electrochemical sensor, Response Time less than 30 seconds, Measurement accuracy +/- 3% FS, 4-20mA standard signal output and passive relay control port, suitable for a variety of Gas detection needs.

$ 267.00

Two-channel split design supports multi-point centralized control, with 4-20mA signal input and two-level alarm settings, microprocessor to ensure accurate monitoring, relay output can drive external equipment linkage, Operating temperature range -10~ 50 ℃.

$ 140.00