Electric Oven

Electric ovens generate heat through resistance heating elements and maintain a constant temperature inside the chamber with a temperature control system. They are used for drying samples, curing coatings, or heat-treating materials. They are commonly found in laboratories for drying glassware, in industrial settings for curing paint, and in food processing for dehydration.
Selection
When selecting, pay attention to the temperature range and uniformity, determine the inner chamber volume based on the sample size, choose the heating method according to the material's temperature resistance, consider explosion-proof requirements and energy consumption indicators, and select a model with corresponding temperature control accuracy based on the budget.

Terms

Standards

Instruments

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, stainless steel liner corrosion resistance, electric heating tube heating fast and uniform, intelligent digital display easy to operate.

$ 403.00

Microcomputer P.I.D temperature controller, temperature control accuracy +/- 1.0 ℃, volume 136L, with hot air circulation system to improve Temperature Uniformity, support independent temperature limit alarm and optional programming function.

$ 749.00

Adopt electric push Rod to drive Spreader movement, adjustable speed range of 2-200mm/s, temperature accuracy +/- 3 ℃, support Vacuum chuck and electric heating function, improve Spreader uniformity and operation convenience.

$ 2494.00

Application width 300mm, Spreader accuracy +/- 0.005mm, Drawdown blade can be quickly disassembled and cleaned, three independent temperature control oven to ensure uniform drying, suitable for a variety of substrates and Stock processing.

$ 24279.00

The cavity preheating technology implementation uniform temperature distribution, equipped with forced convection system to shorten the temperature recovery time, temperature control accuracy +/- 1 ℃, support 0-9999 minutes timing and remote monitoring function.

$ 791.00

The cavity preheating technology implementation uniform temperature distribution, equipped with forced convection system to shorten the temperature recovery time, support 0.1 ℃ temperature resolution and 0-9999 minutes timing function, to ensure the experimental environment stable and reliable.

$ 1192.00

Temperature control accuracy of +/- 1 ℃, equipped with intelligent digital display and observation window, Inner Chamber dimensions 350 * 450 * 450mm, electric heating tube heating to ensure uniform and stable temperature.

$ 393.00

With a 45 ° test angle and an adjustable speed of 5mm/sec, equipped with a 500g weight and a standard pencil set, stable and low-noise electric control is achieved through a stepper motor.

$ 477.00

Equipped with PID microcomputer intelligent temperature control system, Temperature Fluctuation +/- 1 ℃, temperature resolution 0.1 ℃; The studio is made of mirror stainless steel, Shelf spacing is adjustable, and the bottom heating hood quick-release structure is easy to clean.

$ 780.00

Using microcomputer intelligent PID control technology, Temperature range RT + 5~ 250 ℃, Temperature Fluctuation +/- 1%. External hot air circulation system ensures stable temperature, adjustable studio shelf spacing, easy access to different specifications of samples.

$ 340.00

Temperature control accuracy of +/- 1.0 ℃, temperature resolution of 0.1 ℃, equipped with double-decked tempered Glass observation window and quick-release bottom heating hood, easy to clean and maintain, two heating power to meet different temperature needs.

$ 590.00

Rotation speed of 10000rpm is achieved by using 750W three-phase asynchronous motor, and the electric lifting platform supports 300mm Travel, which can handle 10L materials and work continuously for a long time.

$ 1284.00

Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 1%, equipped with independent temperature controller, hot air circulation system consists of low noise fan and air duct, indoor shelf height and quantity can be adjusted.

$ 343.00

Using microcomputer intelligent PID control technology, temperature control accuracy of +/- 0.5 ℃, equipped with external hot air circulation system to ensure uniform and stable temperature, studio shelf spacing adjustable easy access to samples.

$ 372.00

Adopt low noise fan and air duct to form hot air circulation system, Temperature range RT + 5~ 300 ℃, Temperature Accuracy +/- 1 ℃, Indoor shelf height and quantity can be adjusted, convenient access to different specifications of samples.

$ 741.00

Articles

Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
Evaluation of thermal aging life of hot melt adhesives using high-temperature oven method
This article introduces a method for evaluating the thermal aging life of hot melt adhesives using a high-temperature oven. The principle is based on the Arrhenius equation, where aging is accelerated by increasing the temperature to simulate performance changes under long-term use.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Key Technical Points for Determining Paper Moisture Using the 105℃ Oven Method
This article introduces the specific procedure for measuring paper moisture using the 105°C oven method. The process involves placing paper samples into a 105°C oven and drying them until their weight remains constant, then calculating the moisture content based on the weight difference before and after drying.
Oven combined with analytical balance for determination of solid content
This article introduces a method for determining the solid content of samples in the laboratory by combining an oven and an analytical balance.
Temperature gradient control in high-temperature ovens during thermal resistance testing.
The heat resistance test simulates the performance of materials under high temperatures using a high-temperature oven, and the accuracy of its results is highly dependent on the uniformity of temperature inside the oven. If the temperature gradient is poorly controlled, it can lead to uneven heating of samples from the same batch, compromising the validity of the test.
What are the differences between a vacuum oven and a conventional oven?
The main difference between a vacuum oven and a conventional oven lies in their working pressure. Conventional ovens operate at atmospheric pressure, heating through air convection, making them suitable for routine drying tasks. In contrast, vacuum ovens are evacuated to low pressure to reduce air presence, primarily relying on thermal radiation for heat transfer. This makes them ideal for processing heat-sensitive, oxidation-prone materials or those requiring thorough drying.
Natural Convection vs Forced Air Drying: What’s the Difference Between the Two "Schools" of Laboratory Ovens?
This article introduces two drying methods for laboratory ovens: natural convection and forced air drying. What are the differences between them?
Application of Damp Heat Testing in the Environmental Adaptability Verification of Automotive Components
Humidity and heat testing is an accelerated test method that simulates high-temperature and high-humidity environments, used to evaluate the performance changes of automotive components under humid conditions. It primarily examines the insulation and corrosion resistance capabilities of electrical and electronic components, the aging resistance of interior materials, and the corrosion prevention effectiveness of exterior structural parts.