Integrated Incubator and Shaker functions, Oscillation Frequency 40~ 300rpm, Temperature range RT + 5~ 65 ℃, 304 stainless steel liner and microcomputer PID control, with UV sterilization and automatic storage setting paraMeters.
Adopt diagonal air duct structure to ensure Temperature Uniformity +/- 1 ℃, Water-Jacketed heating can still maintain thermostatic after power failure, equipped with PID control and independent temperature limit alarm system to ensure the safe and stable operation of the experiment.
Integrated Incubator and Shaker functions, small footprint and large bottle load; Temperature range 4~ 65 ℃, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner for easy cleaning, quiet operation and support multi-stage programming.
The interlayer vacuum design is easy to keep warm, the test capacity is about 300ml, the upper and lower holes go in and out for easy connection of the thermostatic Bath, easy to use and easy to clean.
Water-Jacketed heating is used to ensure Temperature Uniformity +/- 1 ° C, and it can still maintain thermostatic after power failure; it has multiple safety mechanisms such as over-temperature protection, leakage protection and low water level stop heating, and supports 1-9999 minutes of timing programming.
Temperature range Tr + 5~ 65 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using double-decked tempered Glass door observation window and heat-resistant silicone rubber sealing ring to improve temperature insulation and sealing, suitable for a variety of foster needs.
150W Philips infrared lamp, peak wavelength 950nm, temperature measurement accuracy +/- 0.5 ° C, insulation accuracy +/- 2%, can quickly compare the insulation performance of different materials, the test time is only 1 minute.
Heating mode heating speed, thermostatic Fluctuation +/- 0.2 ℃, equipped with double-decked door structure and independent temperature limit alarm system, to ensure the safe and stable operation of the experiment.
Set thermostatic foster and oscillation in one, Temperature Fluctuation +/- 0.5 ℃, Oscillation Frequency 40-280 rpm, AC brushless motor and antibacterial stainless steel liner, support continuous operation and timing function.
Set thermostatic foster and oscillation function in one, microcomputer control temperature accuracy of +/- 0.5 ℃, Oscillation Frequency single layer 40-260 rpm, with slow start splash-proof design, stainless steel liner for easy cleaning.
Adopt stainless steel water jacket structure, water-proof heating to ensure Temperature Uniformity +/- 1 ℃, can still maintain thermostatic after power failure, with multi-stage programming and ultraviolet sterilization function.
Set thermostatic foster and oscillation function in one, Microcomputer Control Temperature Frequency, Temperature Fluctuation +/- 0.5 ℃, Oscillation Frequency 40-260 rpm, AC brushless motor maintenance-free, independent temperature limit alarm system to ensure safe operation.
The use of high temperature resistant fiberglass insulation material wOven into a hemispherical internal heating heater, the highest temperature of 380 ℃, heating area and rapid heating, excellent insulation effect, to avoid the risk of open flames.
Water-jacketed structure with accurate and reliable temperature control, Temperature Uniformity +/- 0.2 ℃, can still maintain thermostatic for a long time after power failure, using mirror stainless steel studio and semi-circular design for easy cleaning.
With refrigeration and heating bidirectional temperature regulation function, Temperature range -20~ 60 ℃, mirror stainless steel liner to prevent atomization, support thermostatic fostering and tissue cell preservation.