Temperature and Damp Heat Chamber

The temperature and humidity chamber simulates high-temperature and high-humidity environments through heating and humidification systems, and is used to detect the performance changes of materials under temperature and humidity conditions. It is commonly employed in product aging tests in industries such as electronics and coatings.
Selection
When selecting a temperature and humidity chamber, consider the temperature range, humidity control accuracy, chamber size, uniformity indicators, safety features, and brand service support to ensure compliance with testing standard requirements.

Terms

Standards

Instruments

Adopt digital P.I.D. temperature control, upper and lower heat seal independent temperature control, heat sealing temperature range RT +~ 300 ℃, heat sealing pressure 0.05~ 0.7MPa, support manual and foot pedal start mode, anti-burn safety design.

$ 1413.00

The heat sealing paraMeters are determined by hot pressing sealing method, the temperature control accuracy is +/- 0.1 ℃, the heat sealing temperature can reach 300 ℃, and the upper and lower heat sealing heads have independent temperature control and manual foot pedal dual start mode, which is safe and anti-scalding design.

$ 2110.00

Adopt digital P.I.D. temperature control, temperature control accuracy +/- 1 ℃, heat sealing pressure 0~ 0.7Mpa adjustable, double cylinder structure to ensure pressure equilibrating, heat sealing knife aluminum alloy material uniform heat conduction, support automatic and manual mode.

$ 1663.00

Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, independent temperature control of upper and lower heat sealing heads, good thermal conduction effect of brass heat sealing knife, double-decked thermal insulation design to ensure safe use.

$ 1764.00

Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, heat sealing time 0.1~ 999.9s adjustable, heat head with brass material to ensure uniform heat conduction, double-decked thermal insulation protection to ensure safe operation.

$ 3015.00

The heat sealing paraMeters are tested by hot pressing sealing method, the temperature control accuracy is up to +/- 0.2 ℃, the heat sealing time is adjustable from 0.1 to 999.9s, and the upper and lower heat sealing heads are supported for independent temperature control and a variety of heat cover customization to ensure accurate and reliable test data.

$ 2494.00

Digital P.I.D. temperature control, temperature control accuracy +/- 1 ℃, heat sealing temperature up to 300 ℃; dual cylinder structure to ensure pressure equilibrating, heat cover temperature uniformity, support automatic and manual operation mode, improve test efficiency.

$ 1461.00

The rectangular vacuum Chamber improves space utilization, the stainless steel studio is durable and easy to clean, the Vacuum Level 133Pa ensures efficient handling, double-decked tempered Glass doors are easy to observe, and over-temperature protection enhances safety.

$ 4222.00

The equilibrate temperature control method is used to achieve +/- 0.5 ℃ Temperature Fluctuation, Temperature Uniformity ≤ + 2 ℃, and the large-area observation window can monitor the sample status in real time to meet the strict environment testing requirements.

$ 3822.00

Adopt unique equilibrate temperature control method to achieve High Accuracy Temperature Control, Temperature Uniformity ≤ + 2 ℃, equipped with a large area observation window for real-time observation of sample test status, the studio is made of 304 stainless steel.

$ 4438.00

Digital PID Temperature Control system, temperature control accuracy of +/- 0.2 ℃, the upper and lower heat head independent temperature control, double cylinder synchronous circuit to ensure pressure Balance, heat cover heating uniform, support manual and foot pedal dual operation mode.

$ 1656.00

The heat sealing paraMeters were determined by hot-pressing sealing method, the temperature control accuracy was +/- 1 ℃, the heat sealing time was adjustable 0.1-999 s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured the safety of use.

$ 1200.00

The heat sealing performance was determined by hot pressing sealing method, the temperature control accuracy was +/- 0.2 ℃, the heat sealing time was 0.1~ 999.9s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured safety.

$ 1603.00

The equilibrate temperature control method is used to achieve Temperature Fluctuation ≤ +/- 0.5 ° C, humidity control range is 30-98% RH, equipped with a large area observation window to observe the sample status in real time, and the studio is made of 304 stainless steel.

$ 5705.00

High Accuracy Temperature Control with Unique Equilibrate Temperature Control, Temperature Uniformity ≤ + 2 ℃, Large Area Observation Window for Real-time Observation of Sample Test Status, to meet various environmental adaptability testing needs.

$ 7225.00

Articles