Constant-Temperature Test Tank

The constant temperature test chamber maintains a constant temperature inside the box through a heating and cooling system, and is used for testing the performance of materials at different temperatures. It is commonly employed in laboratory environments to simulate processes such as paint curing and plastic aging.
Selection
When selecting, consider the temperature range covering the testing needs, uniformity affecting data accuracy, tank size matching the sample volume, the control system requiring easy operation, and material corrosion resistance for long-term use.

Terms

Standards

Instruments

Temperature range -5~ 95 ℃, accuracy +/- 0.05 ℃, Tank volume 15L, pump flow 6L/min, providing uniform and constant temperature field source, suitable for a variety of test needs.

$ 1505.00

Temperature range -40~ 95 ℃, temperature accuracy +/- 0.1 ℃, Tank volume 15L, providing uniform and constant temperature field source, suitable for a variety of test needs.

$ 2936.00

Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.

$ 2784.00

Temperature range -40~ 95 ℃, temperature control accuracy +/- 0.1 ℃, Tank volume 7.5L, circulating pump flow 6L/min, providing a uniform and constant temperature environment.

$ 2089.00

Temperature range -10~ 95 ℃, using Air-Cooled fully enclosed Compressor, high cooling efficiency, low noise, the inner Tank is made of stainless steel, good thermal insulation performance.

$ 2426.00

Air-Cooled fully enclosed Compressor and overall foaming process, high cooling efficiency and good insulation performance, Temperature range of -40~ 95 ℃, Tank size of 300 * 240 * 150mm.

$ 3599.00

Temperature range -20~ 95 ℃, using Air-Cooled fully enclosed Compressor, efficient and fast cooling, low noise and less vibration, the inner Tank is made of stainless steel, and the thermal insulation performance is good.

$ 1676.00

Temperature range -10 ℃, Tank volume 10L, using fully enclosed Compressor unit and circulating water pump, energy saving and prevent scaling pollution of circulating water, protect the normal operation of the instrument.

$ 1379.00

Temperature control range -10~ 95 ℃, accuracy up to +/- 0.05 ℃, equipped with 6L/min circulating pump to ensure uniform temperature, Tank volume 7.5L to meet the needs of multi-sample testing.

$ 1429.00

Using platinum sheet material, Conductivity Detector cell constant 0.1, no temperature compensation function, suitable for pure water and ultra-pure water and other water quality measurement, optional Glass flow Tank.

$ 185.00

Temperature range -20~ 95 ℃, temperature accuracy +/- 0.05 ℃, Tank volume 15L, equipped with 6L/min circulating pump to ensure uniform and stable temperature, suitable for a variety of experimental needs.

$ 1726.00

With dual functions of refrigeration and heating, Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.2 ℃, support multi-stage programming and internal and external circulation, equipped with over-temperature alarm and liquid level protection.

$ 1648.00

Temperature range -10~ 95 ℃, using Air-Cooled fully enclosed Compressor, high cooling efficiency, low noise, the inner Tank is made of stainless steel, and the overall foaming and heat insulation performance of the low temperature Tank is good.

$ 1845.00

Temperature range covers -10~ 100 ℃, Temperature Fluctuation is accurate to +/- 0.05 ℃, support internal and external double cycle mode, tank volume 6L, to meet the needs of various experiments inside and outside the tank.

$ 725.00

Temperature range -20~ 95 ℃, using Air-Cooled fully enclosed Compressor refrigeration, cooling fast low noise, the overall foaming performance of the Tank body is good, the inner Tank is made of stainless steel.

$ 2934.00

Articles

Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
How to Match the Selection of Fineness Gauge with Grinding Process Requirements
The fineness gauge is used to measure the particle dispersion of materials such as slurries and coatings, reflecting the particle size distribution through the depth of grooves on its surface.
Operating Specifications and Result Interpretation of Paint Fineness Gauges
The fineness gauge is used to measure the dispersion of particles in paint. During operation, the sample should be applied to the groove under standard conditions, and a scraper is used to spread it evenly to form a wet film. The particle visibility is then observed under appropriate lighting, and the fineness value is read from the corresponding scale.
Scraper Fineness Gauge for Determining the Fineness of Paste Inks
The Scraper Fineness Gauge is used to measure the dispersion degree of pigment particles in products such as paste inks. Its principle involves scraping a film on a scraper plate with wedge-shaped grooves and observing the scale at which particles appear to assess the fineness, with the result expressed in micrometers.
Application of Gardner Colorimeter in the Determination of Oil and Fat Color
The Lovibond tintometer determines the color of oils and fats by visually comparing them with standard glass color standards, with results expressed as numerical codes. During operation, clarified oil samples are poured into the colorimetric cell and compared with color chips under a stable light source.
The difference between a wire bar coater and a gap-type wet film applicator.
The wire-wound drawdown bar directly quantifies the coating through the gap between wires, making it suitable for thin coating preparation with high precision, particularly for low-viscosity fluids. In contrast, the gap-type wet film applicator indirectly controls film thickness through the groove depth, with the actual coating thickness significantly influenced by material properties, making it more suitable for high-viscosity coatings and thick film preparation.
The difference between a wire-wound rod coater and an extrusion coating rod
This article primarily compares the technical differences between wire-wound and extrusion coating rods. Although they are interchangeable in most scenarios, there are subtle variations in liquid loading capacity due to their distinct groove principles.