Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the accuracy of light transmitance and haze display is 0.01%, equipped with thin film magnetic fixture and liquid sample Cup, and supports 2000 sets of data storage.
Using parallel illumination hemisphere scattering integrating sphere photoelectric reception mode, light transmitance measurement range 0-100%, haze measurement range 0-99%, with open sample window design, not affected by environment light.
It has the function of switching between light and dark field of view, supports 40X-1600X magnification range, and uses oblique illumination to make the outline of the sample clearly visible. It is suitable for morphological observation of unstained biological samples.
Color temperature adjustment range 2300K-8000K, illumination adjustment range 0-4000Lux, built-in mobile slide can move the camera front and rear, light source light board can swirl/spin to adjust the angle, provide a uniform lighting environment.
The colony contrast is clear by using ring lamp side-shot illumination, equipped with three-digit display and counting probe pen, the counter capacity is 0-999, and it has a 30-day charging standby function, which can reduce the experimental labor intensity.
The imported cold light source does not need to be preheated for 100,000 hours, the minimum display value is 0.001mg/L, supports standard measurement and continuous measurement modes, and the built-in large-capacity lithium battery realizes long standby, which can store 4000 sets of measurement data.
Adopt simple light path design and activity platform to effectively avoid light leakage; Measurement range 0~ 100%, Precision 0.1; Use D65 Illuminant and R457 whiteness formula to ensure stable and reliable measurement.
Using imported cold light source, Optical inspection Stability up to +/- 0.001A/20min, life 100,000 hours; Colorimetric digestion integrated tube design, support a variety of heavy metals detection, minimum detection value of 0.001mg/L.
The imported cold light source does not need to be preheated for 100,000 hours, the detection limit is 0.01mg/L, and the digestion Colorimetric integrated tube is safe and fast. It can store 4000 sets of data and has a variety of transmission interfaces.
Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the light transmitter and haze measurement accuracy are 0.01%, support U disk storage and USB communication, equipped with thin film magnetic fixture and liquid sample Cup.
Adopting imported cold light source technology, the lifespan is up to 100,000 hours; the detection sensitivity is as high as 0.001mg/L; the Colorimetric integrated tube design is supported, and the operation is safe and convenient; the built-in rechargeable battery lasts for a long time.
The imported cold light source does not need to be preheated for 100,000 hours, supports 0.001mg/L high Sensitivity detection, digests Colorimetric integrated tube to make the measurement safe and fast, can store 4000 sets of data and support multi-mode power supply.
Provide adjustable illuminance and Color temperature visible light, Color temperature range 2300K-8000K, illuminance up to 3000LX, infrared wavelength 850nm optional, radiation intensity greater than 400uW/CM ², stable light color without stroboscopic, life over 10,000 hours.
The imported cold light source does not need to be preheated for 100,000 hours, supports 0.001mg/L high Sensitivity detection, is equipped with a digestion Colorimetric integrated tube to achieve safe and fast measurement, and has 4000 sets of data storage and a variety of transmission interfaces.
Transmission surface uniformity of more than 93%, Color temperature adjustment range 2300K-8000K, Illuminance adjustable 0-160,000 Lux, Support Frequency adjustment 1-100KHz, life of more than 10,000 hours, can be connected through RS485 or WIFI computer control.