Intrinsically Safe Temperature Measuring Instrument

Intrinsically safe temperature measuring instruments prevent sparks from igniting explosive atmospheres by limiting circuit energy, utilizing infrared or thermocouple sensors to detect surface temperatures of objects. They are used for equipment monitoring and process temperature measurement in hazardous locations such as chemical plants and oil and gas facilities, ensuring that temperature measurement operations do not cause safety incidents.
Selection
Select the required explosion-proof level to match the classification of the hazardous area on site, ensure the temperature measurement range covers process requirements, and the response speed meets dynamic monitoring needs. Consider that the probe type should be suitable for the surface characteristics of the measured object, the equipment must possess legally required explosion-proof certifications, and balance operational convenience with environmental durability.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Instruments

Intrinsically safe explosion-proof design, up to CT4 grade, equipped with explosion-proof Sensor and display. Table size 410x510mm, weighing range 110kg, accuracy 10g, stable structure, support external calibrating and a variety of functions.

$ 190.00

Using EX-SH784050-100 carbon steel scale body and stainless steel mask, the structure is stable. Range 61kg, Readability 1g, Fast Response Time. With intrinsically safe Explosion-proof level CT4, and standard battery, support no power use.

$ 211.00

With Speedsafe ™ safe speed protection to prevent motor no-load acceleration damage; with chemical corrosion resistant ABS shell, lightweight and durable. Speed range 100~ 1000rpm, Max. stirring Capacity 1 liter.

$ 396.00

Driven by compressed gas, torque can reach 80N.cm, with strong load start-up ability; explosion-proof and spark-free design, operation safety is not affected by the environment; a variety of Impeller optional, adapt to different viscosity media.

$ 1361.00

Microcomputer temperature and humidity controller, Temperature Fluctuation +/- 0.5 ℃, humidity fluctuation +/- 5% RH, with over-temperature protection, independent temperature limit alarm system to ensure safe and stable operation of the experiment.

$ 6691.00

Temperature range -20 ℃, pump flow 8L/min, using fully enclosed Compressor unit and circulating water pump, energy saving and anti-scaling, protect precision instruments in high temperature environment normal operation.

$ 1093.00

Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.

$ 3078.00

Silicon Photocell, photovoltaic cell detection to ensure accurate and stable measurement, potassium and sodium can be detected at the same time and have lithium calcium detection function, small sample Sensitivity, Response Time is less than 8 seconds, with flameout protection function safe and reliable.

$ 677.00

Adopting explosion-proof, burn-seal, intrinsically safe composite explosion-proof technology, with anti-suction valve and gas ballast valve, the pumping rate is 16m ³/h, the ultimate pressure is 0.005mbar, and the noise value is 58dB (A).

$ 1063.00

Mirror stainless steel liner is easy to clean, temperature uniformity +/- 1 ℃, humidity fluctuation +/- 5% RH, with over-temperature protection and intelligent controller to ensure safe and reliable experiments.

$ 5897.00

Fluorine-free design, temperature uniformity +/- 1 ℃, humidity fluctuation +/- 5 %~ +/- 8% RH, with over-temperature, leakage, Sensor fault multiple alarm protection functions to ensure safe operation of the experiment.

$ 1229.00

Temperature range -70~ 150 ℃, humidity uniformity +/- 2% -3% R.H., multi-layer conductive film observation window anti-frost design, equipped with independent over-temperature protector to ensure safe operation of the equipment.

$ 9384.00

Fluorine-free design, Temperature range -40~ 85 ℃, Humidity control 45~ 95% RH, mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safe operation.

$ 4843.00

Using environmentally friendly refrigerant design, temperature range -20~ 85 ℃, humidity fluctuation +/- 5% RH, with over-temperature protection and water shortage alarm function, to ensure the safe and stable operation of the experiment.

$ 4041.00

Using special molding process heater high temperature without warping deformation, Temperature range RT +~ 999 ℃, resolution +/- 1 ℃, touch button operation is simple, the working panel temperature is uniform.

$ 143.00