Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.
Mirror stainless steel liner and high-efficiency air circulation system, Temperature range -5~ 80 ℃, Humidity deviation +/- 3% R.H., support 99 cycle programs to ensure experimental Stability and uniformity.
Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.
The equilibrate temperature control method is used to achieve Temperature Fluctuation ≤ +/- 0.5 ° C, humidity control range is 30-98% RH, equipped with a large area observation window to observe the sample status in real time, and the studio is made of 304 stainless steel.
The 150L studio volume is equipped with ALLCOLD ™ equilibrate refrigeration technology, which supports automatic defrosting and continuous operation; the ALLFLOWTM air circulation system guarantees temperature uniformity, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 2%.
Humidity Control Range 80~ 95% RH, Temperature resolution 0.1 ℃, Humidity deviation +/- 3% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safety.
Adopt mirror stainless steel liner and PID Control mode, Temperature range 0~ 60 ℃, Humidity deviation +/- 5~ 8% R.H., 99 cycle programs and independent temperature limit alarm system.
Adopt equilibrating Conditioning Control system, Temperature and Humidity control range -20~ 150 ℃ and 20~ 98% R.H., with multi-stage heating and energy saving functions to ensure long-term accurate operation.
Adopt equilibrate Conditioning Control system, Temperature and Humidity control range -40~ 150 ℃ and 20~ 98% R.H., equipped with imported Compressor and environmental protection refrigerant, with automatic calculation control and High Accuracy Stability, avoid test dead angle.
Mirror stainless steel liner is easy to clean, Temperature range -5~ 80 ℃, humidity control 40~ 85% RH, equipped with independent temperature limit alarm system to ensure experimental safety, optional printer to record paraMeter changes.
Temperature range -40~ 150 ℃, humidity control 30~ 98% R. H, Temperature Uniformity ≤ +/- 2 ℃, using PID control solid state relay and steam boiler humidification to ensure stable and reliable operation.
The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.
Using multi-stage programmable PID controller and equilibrate Conditioning method, temperature control fluctuation high temperature +/- 0.5 ℃, humidity control deviation +/- 3% RH, with independent temperature limit alarm and a variety of protection functions.
Adopt equilibrate Conditioning Control system, Humidity control accuracy of +/- 0.1 ℃, equipped with imported Compressor and multi-stage PID calculation, ensure uniform no dead angle; built-in 50mm test hole and energy saving design, support long-term stable operation.
Temperature range 10~ 85 ℃, humidity control 80~ 95% RH, fluorine-free environmental protection design, with independent temperature limit alarm system, mirror stainless steel liner easy to clean, Temperature resolution 0.1 ℃, stable and reliable operation.