Thermal Cycle Dryer

The thermal cycle dryer circulates hot air through a fan to ensure uniform heating and evaporation of moisture from materials. It is used in laboratories for rapid drying of samples such as coatings and plastics, preventing localized overheating from affecting test results.
Selection
When selecting, consider matching the temperature range with the sample characteristics, ensuring the chamber volume accommodates the sample size, and pay attention to the heating rate and temperature control accuracy. The type of fan affects airflow uniformity, so choose between horizontal or vertical airflow based on the material form.

Terms

Standards

Instruments

With 260 * 200 thermal imagery resolution and 70mK thermal Sensitivity, it can quickly locate the abnormal temperature rise point of the circuit board, support -10~ 120 ℃ temperature measurement range, equipped with adjustable lens and multi-directional adjustment bracket, easy to accurately observe the thermal distribution of the circuit board.

$ 1022.00

The principle of thermal radiation is used to keep the liquid temperature below the boiling point and avoid water droplets in the gas. The double condensation cycle design improves the extraction effect of pure water, and the output of pure water reaches 800-1000ml/hour. No heavy metals are detected by flameless atomic absorption analysis.

$ 548.00

Adopt two-box mobile structure, air pressure drive test object Impact, Thermal Shock mechanism moving time within 10 seconds, temperature recovery time within 5 minutes, in line with MIL and other international test standards.

$ 19809.00

Using two-box mobile Impact structure, Thermal Shock mechanism moves within 10 seconds, temperature recovery time ≤ 5 minutes, equipped with rigid polyurethane foam insulation material, effective energy saving and waterproof and moisture proof.

$ 23682.00

Adopting triple-channel thermal insulation structure, the throttle switching time is completed within 10 seconds, and the temperature recovery time is completed within 5 minutes. With 96 test specification settings, the Impact time can reach 9999 minutes, and the cycle period is 9999 times, meeting the needs of High Accuracy Temperature Control.

$ 16372.00

Support thermal deformation and Vicat softening point test, Temperature range up to 300 ℃, Temperature control accuracy +/- 0.5 ℃, mechanical mixing and large capacity Tank to ensure uniform insulation field, double control mode operation flexibility.

$ 2300.00

The transient planar heat source method is used, the test time is not more than 160 seconds, the Sensitivity is 0.00001, and the thermal conductivity of 0.0001 to 50W/(m * K) can be measured. It supports a variety of morphological samples and meets international standards.

$ 12983.00

Equipped with programmed vacuum cycle function, drying time is shortened by more than 50%, temperature control accuracy +/- 1 ℃, support 7 groups of 63-step Program settings, digital Vacuum Level control accuracy +/- 1%.

$ 10937.00

The principle of thermal radiation is used to keep the liquid phase temperature below the boiling point, avoid boiling water droplets, and complete gas-liquid separation; the double condensation cycle design improves the extraction efficiency of pure water, the output of pure water reaches 400-500ml/hour, and the Heating power is 800-1000W to ensure that no heavy metals are detected.

$ 432.00

Using oil Bath heating medium, Temperature range from room temperature to 200 ℃, temperature control accuracy +/- 0.5 ℃, equipped with sample clamping grid to ensure temperature stability, suitable for various film thermal cissing rate tests.

$ 1510.00

Pure oil-free design ensures clean gas, exhaust volume of 1500L/min, automatic start and stop to reduce energy consumption, pressure dew point 2-10 ℃, suitable for a variety of industry needs.

$ 766.00

Adopt pure oil-free design to ensure clean gas, dew point range -40~ -60 ℃, exhaust volume 600L/min, automatic start and stop to reduce energy consumption, no need for special personnel on duty and easy maintenance.

$ 1114.00

Using Three-Box structure air circuit switching technology, Temperature range covers -60 ° C to 150 ° C, the maximum cycle period is 9999 times, with binary refrigeration system to achieve rapid cooling, support automatic cycle and manual Impact mode.

$ 14548.00

The two-box mobile structure is adopted, the Thermal Shock mechanism moves within 10 seconds, and the temperature recovery time is within 5 minutes. It is equipped with HFC environmentally friendly refrigerant and binary ultra-low temperature freezing system, which has high cooling speed and efficiency. It supports paperless recording and real-time Linear dispersion display function.

$ 16840.00

Temperature resolution of 0.1 ℃ and heating rate of 0.1~ 20 ℃/min can be adjusted continuously. It supports hot stage method and visual measurement, and is suitable for the study of thermal characteristics of trace samples.

$ 5971.00

Articles