Low Temperature Constant Humidity Chamber

The low-temperature constant humidity and heat chamber maintains a set low-temperature and high-humidity environment within a sealed space through a refrigeration system and a humidification device. It is used to simulate the weather resistance of products under damp and cold conditions, commonly applied in testing fields such as electronic components and material aging.
Selection
When selecting, ensure the temperature range covers testing requirements, humidity control accuracy meets standards, and chamber volume accommodates sample size. Consider compressor performance to ensure cooling rate, and examine condensation drainage design. Verify program control functions and data recording methods, and check the corrosion resistance of the chamber material.

Terms

Standards

Instruments

Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.

$ 3078.00

Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.

$ 7871.00

Humidity Control Range 80~ 95% RH, Temperature resolution 0.1 ℃, Humidity deviation +/- 3% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safety.

$ 1953.00

Adopt mirror stainless steel liner and PID Control mode, Temperature range 0~ 60 ℃, Humidity deviation +/- 5~ 8% R.H., 99 cycle programs and independent temperature limit alarm system.

$ 1414.00

Adopt multi-stage programmable PID controller to achieve accurate temperature and Humidity control, with small fluctuations; unique air duct circulation system to ensure uniform temperature and Humidity; with 100 sets of programs and 1000 segments capacity, support RS-232 or RS-485 communication interface, easy data monitoring and remote operation.

$ 9152.00

Temperature range -20~ 100 ℃, Humidity deviation +/- 3% R. H, using all fluorine-free environmental protection design, multi-stage programmable PID controller to ensure accurate and stable insulation Humidity control, with independent temperature limit alarm system to ensure safety.

$ 6194.00

The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.

$ 5110.00

Using Nidec compressor and DuPont environmental protection refrigerant, Humidity control accuracy of 0.1 ℃, equipped with double-decked vacuum heating defrosting observation window and stainless steel sample holder, support multi-stage programming and Data storage.

$ 3301.00

Using French Taikang Compressor and multi-wing air supply circulation, Temperature Uniformity ≤ +/- 2 ℃, humidity deviation + 2-3% R.H, with independent temperature limit alarm and double-decked Glass observation window to ensure safe and reliable testing.

$ 6367.00

Temperature range 10~ 85 ℃, humidity control 80~ 95% RH, fluorine-free environmental protection design, with independent temperature limit alarm system, mirror stainless steel liner easy to clean, Temperature resolution 0.1 ℃, stable and reliable operation.

$ 1627.00

Imported Humidity Sensor and Compressor, temperature control accuracy of +/- 0.5 ℃, humidity deviation +/- 3% RH, equipped with independent temperature limit alarm system and test hole to ensure the safety and reliability of the experiment.

$ 4122.00

Adopt cascade refrigeration system to achieve -70 ℃ low temperature, with 1000 segment program control capacity, support RS-232 communication interface and Chinese and English display switching, Temperature Uniformity up to +/- 1.0 ℃ and humidity fluctuation +/- 2.0% RH.

$ 7287.00

Temperature range -40~ 100 ℃, humidity control 35~ 95% RH, fluorine-free design, imported stainless steel liner, support multi-stage programming and remote communication, ensure uniform and stable insulation Humidity.

$ 5307.00

The equilibrate temperature control method is used to achieve Temperature Fluctuation ≤ +/- 0.5 ° C, humidity control range is 30-98% RH, equipped with a large area observation window to observe the sample status in real time, and the studio is made of 304 stainless steel.

$ 5705.00

Adopt fluorine-free environmental protection design, Humidity Control Range 35-95% RH, input Power 2300W, with PID automatic calculation function, ensure accurate and stable thermal insulation Humidity control, equipped with multiple Safety protection systems.

$ 5405.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Electronic Tensile Testing Machine Measures the Right-Angle Tear Strength of Films
This article explains how to measure the right-angle tear strength of films using an electronic tensile testing machine. During the test, a film specimen with a right-angle notch is first clamped onto the testing machine and stretched at a constant speed. The machine records the changes in force during the tearing process.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.
Humidity and Heat Test Chamber for Evaluating Coating Performance under High Temperature and High Humidity Conditions
This article introduces how a humidity and heat test chamber is used to evaluate the performance of coatings in high-temperature and high-humidity environments. Coatings are widely used in industries such as automotive and electronics, but they are prone to issues like reduced adhesion and blistering under actual high-temperature and high-humidity conditions.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.
Method for Determining Peel Strength of Hot Melt Adhesives Using an Electronic Tensile Tester
This article introduces the standard method for determining the peel strength of hot melt adhesives using an electronic tensile testing machine. The test employs a 180° peel mode, where a sample coated with hot melt adhesive is clamped in the machine's fixtures and peeled at a constant speed. The peel strength is calculated based on the recorded force variations.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.