Adopt ultra-low power consumption single chip standby for more than 6 months, imported high luminance Illuminant to ensure repeability +/- 1% F.S., IP65 protection and 0.01NTU resolution, support USB connection and data storage.
Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.
Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.
Using ultra-low power consumption single chip standby for up to 6 months, equipped with imported high stability Optical inspection system to achieve +/- 1% F. S Accuracy, IP65 protection design to ensure harsh environment reliability.
Adopt mirror stainless steel liner and PID Control mode, Temperature range 0~ 60 ℃, Humidity deviation +/- 5~ 8% R.H., 99 cycle programs and independent temperature limit alarm system.
The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.
Humidity Control Range 80~ 95% RH, Temperature resolution 0.1 ℃, Humidity deviation +/- 3% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safety.
Adopt stepper motor direct drive to ensure accurate speed, equipped with RTD temperature probe real-time monitoring, Measurement accuracy of +/- 1% F. S, with ultra-low viscosity adapter to extend Measurement range to 1mPa · s.
Temperature range -20~ 150 ℃, humidity control 30~ 98% R.H., stainless steel liner and ultra-fine Glass insulation cotton, equipped with independent over-temperature protection and multi-layer conductive film observation window to ensure stable and reliable testing.
Using French Taikang Compressor and multi-wing air supply circulation, Temperature Uniformity ≤ +/- 2 ℃, humidity deviation + 2-3% R.H, with independent temperature limit alarm and double-decked Glass observation window to ensure safe and reliable testing.
Temperature range -20~ 100 ℃, Humidity deviation +/- 3% R. H, using all fluorine-free environmental protection design, multi-stage programmable PID controller to ensure accurate and stable insulation Humidity control, with independent temperature limit alarm system to ensure safety.
Imported Humidity Sensor and Compressor, temperature control accuracy of +/- 0.5 ℃, humidity deviation +/- 3% RH, equipped with independent temperature limit alarm system and test hole to ensure the safety and reliability of the experiment.
Temperature range 10~ 85 ℃, humidity control 80~ 95% RH, fluorine-free environmental protection design, with independent temperature limit alarm system, mirror stainless steel liner easy to clean, Temperature resolution 0.1 ℃, stable and reliable operation.
Adopt multi-stage programmable PID controller to achieve accurate temperature and Humidity control, with small fluctuations; unique air duct circulation system to ensure uniform temperature and Humidity; with 100 sets of programs and 1000 segments capacity, support RS-232 or RS-485 communication interface, easy data monitoring and remote operation.
Using Nidec compressor and DuPont environmental protection refrigerant, Humidity control accuracy of 0.1 ℃, equipped with double-decked vacuum heating defrosting observation window and stainless steel sample holder, support multi-stage programming and Data storage.