Solution Interface Tension Meter

The solution interfacial Tensiometer measures the intermolecular forces at the liquid surface or interface, directly reading tension values using principles such as the ring method or pendant drop method. It is used to detect the wettability of coatings, the spreading force of inks, the uniformity of paper coatings, and to monitor changes in liquid surface properties during production processes.
Selection
When selecting, consider matching the properties of the liquid to be tested with the measurement principle: viscous liquids are suitable for the rotational method. Ensure the measurement range covers the actual surface tension range. Pay attention to the precision of temperature control. Confirm the corrosion resistance of the sample cell material. Check whether the data output interface meets recording requirements.

Terms

Standards

Instruments

Using BNC interface design, equipped with 60mL reference filling solution and calibrated solution, Measurement range, Response fast and stable, suitable for a variety of water quality environment testing needs.

$ 309.00

Built-in 3mol KCl can add reference solution, can supplement electrolysis solution to maintain measurement accuracy, prolong service life; compact design specification Φ 12mm × 120mm, suitable for a variety of containers, Measurement range 0-14pH and 0-60 ℃, to meet routine detection needs.

$ 86.00

The built-in 15ml test solution can be used for more than 100 times, the pen tip is designed to reduce liquid volatilization, in line with ASTM D2578 and TAPPI T698 international standards, the valid period is 6-8 months.

$ 98.00

General ion standard solution with a concentration of 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating needs.

$ 135.00

Using plastic shell with 1 Meter BNC interface cable, specification is Φ 12mm × 120mm, built-in 3mol KCl gel reference solution without maintenance, Measurement range 0-14pH and 0-60 ℃, suitable for a variety of detection scenarios, providing stable and accurate acid alkalinity measurement.

$ 88.00

General ion standard solution with concentration 1000ppm, PTFE solution bottle Encasement, capacity 480mL, suitable for daily calibrating needs.

$ 135.00

General ion standard solution with a concentration of 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating needs.

$ 135.00

Built-in 15ml test solution can be used more than 100 times, pen design to reduce liquid volatilization, in line with ASTM D2578 standard, valid period of 6 months, suitable for a variety of materials surface tension accurate test.

$ 99.00

General ion standard solution concentration 1000ppm, suitable for daily ion calibrating, PTFE solution bottle Encasement, capacity 480mL, water Hardness type.

$ 135.00

Built-in 15ml test solution, can be used more than 100 times, pen design to reduce the contact between dyne liquid and air, in line with ASTM D2578 and TAPPI T698 standards, effectively control the material surface tension.

$ 99.00

The general ion standard solution concentration is 1000ppm, using PTFE solution bottle Encasement, size 190 × 65mm, 500g per bottle, suitable for daily ion calibrating.

$ 135.00

Built-in 15ml test solution can be used more than 100 times, pen design to reduce liquid volatilization, in line with ASTM D2578 standard, 6 months valid period to ensure test accuracy, suitable for a variety of material surface tension detection.

$ 99.00

Glass shell with high strength can withstand temperature up to 80 ℃, can be filled with internal reference solution to prolong service life, and is suitable for the measurement of complex samples such as colloids.

$ 428.00

The general ion standard solution concentration is 1000ppm, using PTFE solution bottle Encasement, size 190 × 65mm, 500g per bottle, suitable for daily calibrating needs.

$ 135.00

Built-in 15ml test solution can be used more than 100 times, pen design to reduce liquid and air contact, in line with ASTM D2578 and TAPPI T698 standards, valid period of 6 months, suitable for a variety of material surface tension test.

$ 99.00

Articles

UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Blade-coating preparation of hole transport layers for perovskite solar cells.
This article introduces the method of preparing the hole transport layer for perovskite solar cells using the doctor-blade coating technique. The doctor-blade coating method involves spreading the solution evenly on the substrate with a blade to form a thin film, making it suitable for large-scale production.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Salt spray test chamber detects the corrosion resistance of coatings.
The salt spray test chamber accelerates the testing of coating corrosion resistance by simulating a salty and humid environment. It uses atomized sodium chloride solution to form salt spray, which settles inside the constant temperature chamber, and conducts tests under neutral or acidic conditions in accordance with standards.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Applicable Scenarios for Neutral Salt Spray and Copper-Accelerated Acetic Acid Salt Spray Tests
Neutral salt spray testing and copper-accelerated acetic acid salt spray testing are both accelerated methods used to evaluate the corrosion resistance of materials, simulating saline environments to predict long-term performance. The neutral salt spray test uses a neutral sodium chloride solution, which causes relatively mild corrosion and is suitable for general metals and coatings, such as automotive parts.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.
The laboratory coating machine provides uniform coating for OCA optical adhesive and AR coating.
The laboratory film coater is a precision instrument used to prepare uniform thin films on substrates, playing a crucial role in the research and development of OCA optical adhesives and AR coatings. It ensures consistent film thickness and prevents defects by precisely controlling parameters such as coating speed, gap distance, and solution viscosity.
Application of Coating Machines in the Fabrication of Functional Layers for Perovskite Solar Cells
This article introduces the application of coating machines in the preparation of functional layers for perovskite solar cells. The performance of perovskite cells depends on the uniformity and quality of thin films, such as the electron transport layer and the light-absorbing layer, which are primarily prepared through solution-based coating methods.