Paint Experiment Quick Hand

Paint Lab Express is a portable instrument designed for rapid testing of coatings. It utilizes built-in sensors to detect parameters such as viscosity and density, enabling immediate data acquisition on production lines or at job sites. This assists in adjusting formulations and monitoring quality.
Selection
When selecting, consider that the measurement parameters match the type of coating, the operation interface is simple and easy to use, the instrument size is suitable for on-site portability, calibration and maintenance are convenient, and data can be integrated with existing recording systems.

Terms

Standards

Instruments

Hand type easy to operate, load 1000g, standard 6B-6H pencil, suitable for film hardness testing, test temperature 23 +/- 2 ℃ and Humidity 50 +/- 5% environment.

$ 341.00

Adopt 0-3000rpm stepless speed regulation, Processing capacity 10-100L, with full explosion-proof structure and hand lifting system, suitable for dispersing and mixing of high viscosity materials.

$ 1661.00

Hand crank type is easy to operate, load 1000g +/- 1g, scratch speed about 1mm/s, test angle 45 °, standard 6B-6H pencil, in line with a number of international standards, through the pencil Hardness grade to accurately evaluate the scratch performance of the paint film.

$ 325.00

Adopt gear pair drive, hand-pressed operation, rated load 500N, Travel 70mm, the upper and lower height of the frame can be adjusted, Force Gauge has a positioning structure, suitable for batch testing.

$ 256.00

The paint film adhesion was measured by the circular trace method, the drawing diaMeter was 0~ 10.5mm, and the Working Travel was 80mm. The integrity of the paint film was evaluated according to seven grades, and the operation was simple and reliable.

$ 267.00

Adopt hand-crank mechanical pressurization method, Heating power 650W, Mold sleeve specification < 40mm, suitable for small or irregular samples, support thermosetting material inlay.

$ 649.00

Hand-crank mechanical pressurization is easy to operate, digital temperature controller to ensure stable temperature, Heating power 440W, mold sleeve specification < 25mm, suitable for thermosetting material inlay, protect the edge of the sample.

$ 517.00

Adopt gear pair transmission, hand-pressed operation, the height of the frame can be adjusted up and down, Force Gauge up and down movement is equipped with positioning structure, rated load 500N, Travel 70mm, suitable for batch testing.

$ 180.00

Rated load 500N, rack and pinion drive, hand pressure operation is simple and stable, large foot design to ensure smooth measurement process, Travel 75mm, suitable for Force Gauge installation for tensile or plug force test.

$ 181.00

It can measure the ability of the paint film to deform with the substrate without damage. It is equipped with a shaft Rod with a diaMeter of 50mm and 100mm.

$ 309.00

Hand pressure type is easy to operate, the rack and pinion transmission is smooth, the digital display ruler can display the displacement and lock the Travel, the maximum test load is 500N, the measurement Travel is 200mm, and the base is stable and the fuselage is heavy.

$ 248.00

The drying process of paint film and putty film can be accurately measured by using circular track needle design, equipped with four different radius needle (R0.25/0.5/1.0/1 mm), and the track period is 24h/r.

$ 223.00

It can test the cracking of the paint film after bending 180 degrees in 1-3 seconds, and the diaMeter range of the shaft Rod is 2-32mm. It is suitable for the test plate with a thickness of not more than 1.0mm. Quick evaluation of flexibility.

$ 280.00

Impact height of 120 cm, hammer mass 1000g, no secondary rebound phenomenon after impact, punch diaMeter 16mm, can accurately determine the impact strength of the paint film.

$ 370.00

Adopt all directions swing vibration mode to ensure that the paint is fully mixed, Vibration Frequency 550 times/min, equipped with 0-15 minute timing function, suitable for 80-240mm barrel height range.

$ 1171.00

Articles

Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Technical Details of Measuring Paint Contrast Ratio Using Black-and-White Checkerboard Method with Hiding Power Card
This article introduces a method for measuring the hiding power of coatings using black and white checkerboard paper.
Wear testing machine evaluates the wear resistance performance of wood and floor coatings.
This article introduces how to use a wear testing machine to evaluate the wear resistance of wood and floor coatings.