Vinyl Chloride Detector

The vinyl chloride detector measures the concentration of vinyl chloride in the air using electrochemical or photoionization sensors. When vinyl chloride comes into contact with the sensor, it generates an electrical signal or ion current, which the instrument then converts into a concentration reading. It is used for leak warning and operational safety protection in settings such as chemical production and environmental monitoring.
Selection
When selecting, consider that the detection range should cover the on-site concentration. Electrochemical sensors are suitable for routine detection, while photoionization is more sensitive to low concentrations. Ensure that the explosion-proof rating matches the environment, and the response time meets safety requirements. Check the calibration cycle and maintenance costs. Compare the data stability and service life of different brands.

Standards

Instruments

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, with explosion-proof structure and a variety of signal output interfaces, support remote wireless transmission and customized range.

$ 435.00

Designed for chloride ion composite ElectRode, provides stable calibrating performance, Encasement size 250ml, to ensure long-term use Reliability and measurement conformity.

$ 110.00

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and automatic Zero tracking function, support a variety of signal output interfaces and remote monitoring.

$ 638.00

Adopt pump-suction sampling and dust-proof design, equipped with dust filter, range 0~ 500ppm, resolution 1ppm, Response Time T90 ≤ 20s, can customize paraMeter settings and store 120,000 sets of data.

$ 1042.00

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and explosion-proof certification, support a variety of signal output and remote monitoring functions.

$ 638.00

Electrochemical sensor technology, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, Intrinsic Safety (IS) design and automatic Zero tracking function, support multiple signal output and remote monitoring.

$ 764.00

Electrochemical sensor, range 0-200ppm, accuracy +/- 2% F. S, with intrinsically safe circuit design and explosion-proof certification, support for a variety of signal output interfaces, Response Time is less than 10 seconds, suitable for harsh industrial environments.

$ 764.00

Using Industrial-grade Sensor and Microcontrol Technology, Response Time is less than 60 seconds, and Sensor life is 2 years. It has waterproof, dustproof and explosion-proof characteristics, and is detected by natural diffusion. Sensitivity and Repeatability are good.

$ 248.00

Adopt pump suction sampling, Response Time T90 ≤ 20 seconds, detection accuracy ≤ +/- 3%, IP65 Protection Rating, equipped with dust filter, adapt to harsh environment, support multi-Sensor expansion.

$ 603.00

Electrochemical sensor, resolution up to 0.1ppm, Response Time less than 60 seconds, with sound, light and vibration triple alarm, IP65 Protection Rating to adapt to harsh environments.

$ 235.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds. Support a variety of signal output and wireless transmission, with explosion-proof structure and remote alarm function.

$ 280.00

The explosion-proof structure design, Response Time is less than 30 seconds, resolution of 0.1ppm, can detect a variety of gas concentrations, with sound and light alarm function to ensure safety monitoring.

$ 251.00

Smooth matte surface does not contain plasticizer, reflectance < 4%, thickness 0.25 +/- 0.02mm, to ensure test data Repeatability and comparability, in line with national standards.

$ 130.00

With manual and automatic temperature compensation function, Measurement range 0-6 PCL, resolution up to 0.01 PCL, easy operation and intuitive and accurate digital display, suitable for a variety of water quality monitoring scenarios.

$ 382.00

Adopt automatic potential Titrimetric method, built-in standard method to directly read the results, support silver nitrate (AgNO3) calibration and blank experiment, data management can store 200 sets of results, titration analysis Repeatability of 0.20%.

$ 3667.00